{"title":"Huawei Data Center Switches","description":"\u003cp\u003e\u003cspan\u003eHuaTelecom specializes in providing CloudEngine Data Center Switches — Ethernet switches widely used in diverse applications and in different network sizes, in both data centers and high-end campus networks — feature network scaling, automation, programmability, and real-time visibility.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"huawei-s7703-switch","title":"Huawei S7703 Switch","description":"\u003ch4\u003eS7703  Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S7703 Switch is one of the S7700 series smart switches, and the S7700 series switches are smart routing switches designed for next-generation enterprise networks. The S7700 series switches can offer voice, video, and data services, helping enterprises build routing and switching integrated end-to-end networks.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series design is based on Huawei’s intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive HQoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services. The S7700 also features super scalability and reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eS7703\u003c\/span\u003e\u003cspan\u003e chassis provides two system power supply slots: PWR1 and PWR2, which support DC and AC power modules. PWR1 is in area A, and PWR2 is in area B. Area A and area B act as a hot backup of each other.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eS7703\u003c\/span\u003e\u003cspan\u003e chassis is 4 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 175 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 175 mm x 442 mm x 585 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703_chassis.png?v=1755063928\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-simpletableborder\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e1. Three of the following service cards can be installed:\u003c\/p\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\" id=\"EN-US_CONCEPT_0177092964__note170458136183503\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p146706654183503\"\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e4. Two power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e5. One PoE power modules\u003c\/p\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177092964__EN-US_CONCEPT_0177092964_mMcCpPsS_ul_dc_s_hw_0903001\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1524196833183503\"\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li188150176183503\"\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li767794570183503\"\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li954442649183503\"\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e6. Front ESD jack\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e7. Cable management frames\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-tb-normal\" id=\"EN-US_CONCEPT_0177092964__tabled0e2313\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.7.4.6.2.2.3.1.1\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.7.4.6.2.2.3.1.2\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV100R006C00: 144xFE, 144xGE, 36x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R001C00: 144xFE, 144xGE, 120x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R002C00 to V200R007C00: 144xFE, 144xGE, 120x10GE, 6x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R008C00 to V200R009C00: 144xFE, 144xGE, 120x10GE, 6x40GE, 6x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R010C00 to V200R019C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R019C00 to V200R020C10: 144xFE, 144xGE, 144x10GE, 24x40GE, 18x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R021C00 and later versions: 144xFE, 144xGE, 144x10GE, 36x40GE, 18x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eIn an N66E or N68E cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li_poe01\"\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003ePoE power module backup: no backup\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMaximum output power: 3000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e1000 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177092964__EN-US_CONCEPT_0177092964_mMcCpPsS_ul_dc_s_hw_09059401\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1657257576183503\"\u003eDC input voltage\n\u003cp id=\"EN-US_CONCEPT_0177092964__p1998330659183503\"\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-p\" id=\"EN-US_CONCEPT_0177092964__p1854428973183503\"\u003eMaximum voltage range:\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177092964__ul809651482183503\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li234326063183503\"\u003e1600 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1509437259183503\"\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li2084175163183503\"\u003eAC input voltage\n\u003cp id=\"EN-US_CONCEPT_0177092964__p94366810183503\"\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p991120443183503\"\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li2005701407183503\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p772740490183503\"\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p1853850632183503\"\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p1462631451183503\"\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWith cable management frames (4 U high): 175 mm x 442 mm x 585 mm (6.9 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWithout cable management frames (4 U high): 175 mm x 442 mm x 517.4 mm (6.9 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e10 kg\/31.6 kg (22.0 lb\/69.7 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time between failures (MTBF): 33.8 years\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAvailability: 0.9999964\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\" id=\"EN-US_CONCEPT_0177092964__note_section6_01\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p204769567183503\"\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177092964__ul_dc_s_hw_09059402\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li221157362183503\"\u003eOperating temperature and altitude:\n\u003cp id=\"EN-US_CONCEPT_0177092964__p491897288183503\"\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p552208305183503\"\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177092964__p468791767183503\"\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li314421553183503\"\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1846036463183503\"\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li878094327183503\"\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177092964__ul_dc_s_hw_09064501\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li273946044183503\"\u003eEMC certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1805335276183503\"\u003eSafety certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177092964__li1915639674183503\"\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cdiv class=\"idp-ltr-html-p\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eIntegrated S7703 chassis: 02113304\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS7703 chassis, FCC certified: 02113959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many slots does the Huawei S7703 have and what interface cards are compatible?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 3 service slots + 2 power slots—compatible with all Huawei S7700 series interface cards (10G\/1G SFP+\/SFP\/RJ45\/Combo).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the redundancy features of the Huawei S7703?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Dual power supply (1+1), fan redundancy + ERPS ring protection (≤50ms failover)—ensuring non-stop critical business operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the switching capacity and packet forwarding rate of the S7703?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Switching capacity ≥2.4Tbps (expandable to 4.8Tbps), packet forwarding rate ≥1800Mpps—line-speed forwarding for all ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is the Huawei S7703 suitable for small-medium enterprise backbone networks?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Flexible 3-slot expansion + high reliability + cost-effectiveness—it’s the preferred choice for SMB core\/aggregation layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What management systems does the Huawei S7703 support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports CLI\/Web\/iMaster NCE unified management + intelligent O\u0026amp;M—simplifies small-medium enterprise network management.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46891070226584,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703-1.jpg?v=1755064578"},{"product_id":"huawei-s7703-poe-switch","title":"Huawei S7703 PoE Switch","description":"\u003ch4\u003eS7703 PoE  Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S7703 Switch is one of the S7700 series smart switches, and the S7700 series switches are smart routing switches designed for next-generation enterprise networks. The S7700 series switches can offer voice, video, and data services, helping enterprises build routing and switching integrated end-to-end networks.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series design is based on Huawei’s intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive HQoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services. The S7700 also features super scalability and reliability.\u003c\/p\u003e\n\u003cp\u003eThe S7703 PoE chassis provides 3 LPU slots, 2 MCU slots, and 3 power supply slots.\u003c\/p\u003e\n\u003cp\u003eThe S7703 PoE chassis provides three power supply slots: PWR1, PWR2, and PWR3, which support DC and AC power modules.\u003c\/p\u003e\n\u003cp\u003eThe S7703 PoE chassis supports two redundancy modes of power modules: N+1, and N+0. You can run the set power backup-mode command to configure the backup mode of power modules. By default, the power supply redundancy mode is automatic redundancy. That is, the power module roles are automatically determined based on the power and number of power modules.\u003c\/p\u003e\n\u003cdiv\u003eThe power modules of the S7703 PoE chassis have the following roles:\n\u003cul\u003e\n\u003cli\u003eM: indicates a master power module that is supplying power. When the backup mode of power modules is N+N or N+1, N power modules are of the master role.\u003c\/li\u003e\n\u003cli\u003eS: indicates a standby power module. When the backup mode of power modules is N+1, one power module is of the standby role.\u003c\/li\u003e\n\u003cli\u003eA: indicates a power module that is always supplying power. When the backup mode of power modules is N+0, N power modules are of the A role.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eAfter the power supply redundancy mode is configured, run the display power command to view the power module roles.\u003c\/p\u003e\n\u003ch5\u003eS7703 PoE chassis Appearance\u003c\/h5\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703_PoE_chassis.png?v=1755065467\" data-ke-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703_PoE_chassis.png?v=1755065467\"\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Three of the following service cards can be installed:\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd\u003e3. A pair of mounting brackets\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Three power modules\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5. Front ESD jack\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6. Cable management frames\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703_PoE_chassis_structure.png?v=1755065549\" data-ke-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703_PoE_chassis_structure.png?v=1755065549\"\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. One Fan Module\u003c\/td\u003e\n\u003ctd\u003e2. Ground screw\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe ground screw is used to ground the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3. Rear ESD jack\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Air filter\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe air filter prevents dust from entering the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eS7703 PoE chassis\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPU slots\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan slots\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply slots\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum port density\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R013C00 to V200R019C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 144xFE, 144xGE, 144x10GE, 24x40GE, 18x100GE\u003c\/li\u003e\n\u003cli\u003eV200R021C00 and later versions: 144xFE, 144xGE, 144x10GE, 36x40GE, 18x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIn an N66E or N68E cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSS\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption (fully configured, no PoE power supply)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1185W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower specifications\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDC input voltage\u003c\/p\u003e\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -40 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC input voltage\u003c\/p\u003e\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (4 U high): 175 mm x 442 mm x 585 mm (6.9 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (4 U high): 175 mm x 442 mm x 517.4 mm (6.9 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (empty\/fully configured)\u003c\/td\u003e\n\u003ctd\u003e10.3 kg\/33.8 kg (22.7 lb\/74.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReliability and availability\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean time between failures (MTBF): 33.8 years\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999964\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment specifications\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at normal temperature (acoustic power)\u003c\/td\u003e\n\u003ctd\u003e≤ 72 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the PoE power capacity and single-port output of Huawei S7703-PoE?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Total PoE power ≥720W, single-port supports PoE (30W, IEEE 802.3af) \/ PoE+ (60W, IEEE 802.3at)—compatible with all PoE terminals.\u003c\/li\u003e\n\u003cli\u003eQ: How many slots does the Huawei S7703-PoE have and what interface cards are compatible?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 3 service slots + 2 power slots—compatible with Huawei S7700 PoE\/10G\/1G SFP+\/SFP\/RJ45 interface cards.\u003c\/li\u003e\n\u003cli\u003eQ: What redundancy features does the Huawei S7703-PoE support?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Dual power supply (1+1) + ERPS ring protection (≤50ms failover)—ensures non-stop PoE power supply.\u003c\/li\u003e\n\u003cli\u003eQ: Is the Huawei S7703-PoE suitable for small-medium IP surveillance projects?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes! 720W PoE power + 100m transmission + overload protection—ideal for centralized HD camera power and data transmission.\u003c\/li\u003e\n\u003cli\u003eQ: What is the advantage over fixed-port PoE switches?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Flexible slot expansion, support 10G\/1G mixed insertion, dual power redundancy—more scalable for growing small-medium campuses.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46891074191512,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7703-1.jpg?v=1755064578"},{"product_id":"huawei-s7706-switch","title":"Huawei S7706 Switch","description":"\u003ch4\u003eS7706 Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS7706 is one of the S7700 series smart switches, and the S7700 series switches are smart routing switches designed for next-generation enterprise networks. The S7700 series switches can offer voice, video, and data services, helping enterprises build routing and switching integrated end-to-end networks.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series design is based on Huawei’s intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive HQoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services. The S7700 also features super scalability and reliability.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series is available in three models: S7703\/S7703-PoE, S7706\/S7706-PoE, and S7712. The switching capacity and port density of all three models are expandable. The S7700 is based on a new hardware platform, which adopts a left-to-rear ventilation channel to achieve better energy efficiency. Key components work in redundancy mode to minimize risks of system breakdown and service interruption. Using innovative energy-saving chips, the S7700 provides an industry-leading solution for a sustainable energy-saving network.\u003c\/p\u003e\n\u003cp\u003eThe S7706 chassis provides 6 LPU slots, 2 SRU slots, 2 Centralized Monitoring Unit (CMU) slots, 4 system power supply slots, and 4 PoE power supply slots.\u003c\/p\u003e\n\u003cp\u003eThe S7706 chassis provides four system power supply slots: PWR1 to PWR4, which support DC and AC power modules. PWR1 and PWR2 are in area A, and PWR3 and PWR4 are in area B. Area A and area B act as a hot backup of each other, and the power modules in each area work in load balancing mode.\u003c\/p\u003e\n\u003cp\u003ePlease note:\u003c\/p\u003e\n\u003cp\u003eThe power supply slots on the S7703, S7706, and S7712 consist of the system power supply slot and PoE power supply slot, which are independent of each other. By installing the appropriate power modules into the PoE power supply slots, the S7703, S7706, and S7712 can provide PoE capabilities.\u003c\/p\u003e\n\u003cp\u003eThe S7703-PoE\/S7706-PoE differ from the S7703\/S7706, because all power supply slots on the S7703-PoE\/S7706-PoE are shared by the system power supply and PoE power supply.\u003c\/p\u003e\n\u003ch5\u003eS7706 chassis Appearance\u003c\/h5\u003e\n\u003ch5\u003e\u003cimg data-ke-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706_chassis.png?v=1755066047\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706_chassis.png?v=1755066047\" alt=\"\"\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Six of the following service cards can be installed:\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli\u003eInterface cards:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003col\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eNote: The cards supported by a switch depend on the software version. For details, see Hardware Query Tool.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd\u003e3. A pair of mounting brackets\u003cbr\u003enote: The mounting brackets are used to secure the chassis in the cabinet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Two power modules\u003c\/td\u003e\n\u003ctd\u003e5. Two EH1D200CMU00-Centralized Monitoring Unit\u003c\/td\u003e\n\u003ctd\u003e6. Four PoE power modules\n\u003cp\u003e2200 W AC Power Module\u003cbr\u003e800 W AC Power Module\u003cbr\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003cbr\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7. Ground screw\u003c\/td\u003e\n\u003ctd\u003e8. Front ESD jack\u003c\/td\u003e\n\u003ctd\u003e9. Cable management frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical specifications\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV100R006C00: 288xFE, 288xGE, 72x10GE\u003c\/li\u003e\n\u003cli\u003eV200R001C00: 288xFE, 288xGE, 240x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 to V200R007C00: 288xFE, 288xGE, 240x10GE, 12x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 288xFE, 288xGE, 240x10GE, 12x40GE, 12x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R019C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 288xFE, 288xGE, 288x10GE, 48x40GE, 36x100GE\u003c\/li\u003e\n\u003cli\u003eV200R021C00 and later versions: 288xFE, 288xGE, 288x10GE, 72x40GE, 36x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one or two chassis in a cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS card or service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply\u003c\/li\u003e\n\u003cli\u003ePoE power module backup: no backup, 3+1 backup, or 2+2 backup\u003c\/li\u003e\n\u003cli\u003eMaximum output power: 9000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2200 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv\u003eMaximum voltage range:\n\u003cul\u003e\n\u003cli\u003e1600 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (10 U high): 441.7 mm x 442 mm x 585 mm (17.39 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (10 U high): 441.7 mm x 442 mm x 517.4 mm (17.39 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 kg\/61.8 kg (33.1 lb\/136.2 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMTBF: 24.2 years\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eS7706 chassis: 02113305\u003c\/li\u003e\n\u003cli\u003eS7706 chassis, PoE supported: 02113307\u003c\/li\u003e\n\u003cli\u003eS7706 chassis, FCC certified: 02113960\u003c\/li\u003e\n\u003cli\u003eS7706 chassis, PoE supported, FCC certified: 02113962\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How many slots does the Huawei S7706 have and what interface cards are compatible?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 6 service slots + 2 control slots + 2 power slots—compatible with all Huawei S7700 series interface cards (10G\/1G SFP+\/SFP\/RJ45\/Combo).\u003c\/li\u003e\n\u003cli\u003eQ: What are the redundancy features of the Huawei S7706?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Dual control board (1+1), dual power supply (1+1), fan redundancy—0ms failover, ensuring non-stop critical business operation.\u003c\/li\u003e\n\u003cli\u003eQ: What is the switching capacity and packet forwarding rate of the S7706?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Switching capacity ≥4.8Tbps (expandable to 9.6Tbps), packet forwarding rate ≥3600Mpps—line-speed forwarding for all ports.\u003c\/li\u003e\n\u003cli\u003eQ: Is the Huawei S7706 suitable for government\/enterprise multi-service networks?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes! With MPLS VPN isolation, high reliability (MTBF ≥1.1M hours), and dual redundancy—it’s ideal for multi-service bearing.\u003c\/li\u003e\n\u003cli\u003eQ: What management systems does the Huawei S7706 support?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Supports CLI\/Web\/iMaster NCE unified management + intelligent O\u0026amp;M—simplifies large-scale network management.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46891076583576,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706-1.jpg?v=1755066272"},{"product_id":"huawei-s7706-poe-switch","title":"Huawei S7706 PoE Switch","description":"\u003ch4\u003eS7706 PoE Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS7706 is one of the S7700 series smart switches, and the S7700 series switches are smart routing switches designed for next-generation enterprise networks. The S7700 series switches can offer voice, video, and data services, helping enterprises build routing and switching integrated end-to-end networks.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series design is based on Huawei’s intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive HQoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services. The S7700 also features super scalability and reliability.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series is available in three models: S7703\/S7703-PoE, S7706\/S7706-PoE, and S7712. The switching capacity and port density of all three models are expandable. The S7700 is based on a new hardware platform, which adopts a left-to-rear ventilation channel to achieve better energy efficiency. Key components work in redundancy mode to minimize risks of system breakdown and service interruption. Using innovative energy-saving chips, the S7700 provides an industry-leading solution for a sustainable energy-saving network.\u003c\/p\u003e\n\u003cp\u003eThe S7706 PoE chassis provides 6 LPU slots, 2 SRU slots, 2 Centralized Monitoring Unit (CMU) slots, and 8 power supply slots.\u003c\/p\u003e\n\u003cp\u003eThe S7706 PoE chassis supports three redundancy modes of power modules: N+N, N+1, and N+0. You can run the set power backup-mode command to configure the backup mode of power modules. By default, the power supply redundancy mode is automatic redundancy. That is, the power module roles are automatically determined based on the power and number of power modules.\u003c\/p\u003e\n\u003cdiv\u003eThe power modules of the S7706 PoE chassis have the following roles:\n\u003cul\u003e\n\u003cli\u003eM: indicates a master power module that is supplying power. When the backup mode of power modules is N+N or N+1, N power modules are of the master role.\u003c\/li\u003e\n\u003cli\u003eS: indicates a standby power module. When the backup mode of power modules is N+N or N+1, N or one power module is of the standby role.\u003c\/li\u003e\n\u003cli\u003eA: indicates a power module that is always supplying power. When the backup mode of power modules is N+0, N power modules are of the A role.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eAfter the power supply redundancy mode is configured, run the display power command to view the power module roles.\u003c\/p\u003e\n\u003ch5\u003eS7706 PoE chassis Appearance\u003c\/h5\u003e\n\u003ch5\u003e\u003cimg alt=\"\" data-ke-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706_PoE.png?v=1755066498\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706_PoE.png?v=1755066498\"\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Six of the following service cards can be installed:\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd\u003e3. A pair of mounting brackets\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Eight power modules\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5. Two EH1D200CMU00-Centralized Monitoring Unit\u003c\/td\u003e\n\u003ctd\u003e6. Ground screw\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe ground screw is used to ground the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7. Front ESD jack\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8. Cable management frames\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eNOTE:\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R013C00 to V200R019C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 288xFE, 288xGE, 288x10GE, 48x40GE, 36x100GE\u003c\/li\u003e\n\u003cli\u003eV200R021C00 and later versions: 288xFE, 288xGE, 288x10GE, 72x40GE, 36x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one or two chassis in a cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS card or service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2640W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDC input voltage\u003c\/p\u003e\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -40 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC input voltage\u003c\/p\u003e\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (10 U high): 441.7 mm x 442 mm x 585 mm (17.39 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (10 U high): 441.7 mm x 442 mm x 517.4 mm (17.39 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e21.3 kg\/78.1 kg (47.0 lb\/172.2 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMTBF: 24.2 years\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eS7706 PoE chassis: 02115713\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What is the PoE power capacity and single-port output of Huawei S7706-PoE?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Total PoE power ≥1440W, single-port supports PoE (30W, IEEE 802.3af) \/ PoE+ (60W, IEEE 802.3at)—compatible with all PoE terminals.\u003c\/li\u003e\n\u003cli\u003eQ: How many slots does the Huawei S7706-PoE have and what interface cards are compatible?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 6 service slots + 2 control slots + 2 power slots—compatible with Huawei S7700 PoE\/10G\/1G SFP+\/SFP\/RJ45 interface cards.\u003c\/li\u003e\n\u003cli\u003eQ: What redundancy features does the Huawei S7706-PoE support?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Dual control board (1+1) + dual power supply (1+1) + ERPS ring protection (≤50ms failover)—ensures non-stop PoE power supply.\u003c\/li\u003e\n\u003cli\u003eQ: Is the Huawei S7706-PoE suitable for large-scale IP surveillance projects?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes! High PoE power (1440W) + 100m transmission + overload protection—ideal for centralized HD camera power and data transmission.\u003c\/li\u003e\n\u003cli\u003eQ: What management functions does the Huawei S7706-PoE support for PoE terminals?\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Supports batch configuration, power status monitoring, overload alarm + iMaster NCE unified management—simplifies PoE terminal O\u0026amp;M.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46891089952920,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7706-1.jpg?v=1755066272"},{"product_id":"huawei-s7712-switch","title":"Huawei S7712 Switch","description":"\u003ch4\u003eS7712 Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS7712 is one of the S7700 series smart switches, and the S7700 series switches are smart routing switches designed for next-generation enterprise networks. The S7700 series switches can offer voice, video, and data services, helping enterprises build routing and switching integrated end-to-end networks.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series design is based on Huawei’s intelligent multi-layer switching technology to provide intelligent service optimization methods, such as MPLS VPN, traffic analysis, comprehensive HQoS policies, controllable multicast, load balancing, and security, in addition to high-performance Layer 2 to Layer 4 switching services. The S7700 also features super scalability and reliability.\u003c\/p\u003e\n\u003cp\u003eThe S7700 series is available in three models: S7703\/S7703-PoE, S7706\/S7706-PoE, and S7712. The switching capacity and port density of all three models are expandable. The S7700 is based on a new hardware platform, which adopts a left-to-rear ventilation channel to achieve better energy efficiency. Key components work in redundancy mode to minimize risks of system breakdown and service interruption. Using innovative energy-saving chips, the S7700 provides an industry-leading solution for a sustainable energy-saving network.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eS7712\u003c\/span\u003e\u003cspan\u003e chassis provides 12 LPU slots, 2 SRU slots, 2 CMU slots, 4 system power supply slots\u003c\/span\u003e\u003cspan\u003e, and 4 PoE power supply slots\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe S7712 chassis has four system power supply slots: PWR1 to PWR4, which support DC and AC power modules. PWR1 and PWR2 are in area A, and PWR3 and PWR4 are in area B. Area A and area B act as a hot backup of each other, and the power modules in each area work in load balancing mode.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note:\u003c\/p\u003e\n\u003cp\u003eThe power supply slots on the S7703, S7706, and S7712 consist of the system power supply slot and PoE power supply slot, which are independent of each other. By installing the appropriate power modules into the PoE power supply slots, the S7703, S7706, and S7712 can provide PoE capabilities.\u003c\/p\u003e\n\u003cp\u003eThe S7703-PoE\/S7706-PoE differ from the S7703\/S7706, because all power supply slots on the S7703-PoE\/S7706-PoE are shared by the system power supply and PoE power supply.\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eS7712 Chassis Appearance\u003c\/span\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/s7712.png?v=1755066835\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-simpletableborder\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e1. Twelve of the following service cards can be installed:\u003c\/p\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100GE Interface Card\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p146706654183503\"\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e4. Four power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e5. Two EH1D200CMU00-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e6. Four PoE power modules\u003c\/p\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1524196833183503\"\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li188150176183503\"\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li767794570183503\"\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li954442649183503\"\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e7. Ground screw\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground screw is used to ground the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e8. Front ESD jack\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e9. Cable management frames\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-tb-normal\" id=\"EN-US_CONCEPT_0177093134__tabled0e6866\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.11.4.6.2.2.3.1.1\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.11.4.6.2.2.3.1.2\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV100R006C00: 576xFE, 576xGE, 144x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R001C00: 576xFE, 576xGE, 480x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R002C00 to V200R007C00: 576xFE, 576xGE, 480x10GE, 24x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R008C00 to V200R009C00: 576xFE, 576xGE, 480x10GE, 24x40GE, 24x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R010C00 to V200R019C00: 576xFE, 576xGE, 576x10GE, 96x40GE, 48x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R019C00 to V200R020C10: 576xFE, 576xGE, 576x10GE, 96x40GE, 72x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R021C00 and later versions: 576xFE, 576xGE, 576x10GE, 144x40GE, 72x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one cabinet for one chassis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eCSS card or service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003ePoE power module backup: no backup, 3+1 backup, or 2+2 backup\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMaximum output power: 9000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e4200 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1657257576183503\"\u003eDC input voltage\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p1998330659183503\"\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-p\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p1854428973183503\"\u003eMaximum voltage range:\n\u003cul class=\"idp-ltr-html-ul\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_ul809651482183503\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li234326063183503\"\u003e1600 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1509437259183503\"\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li2084175163183503\"\u003eAC input voltage\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p94366810183503\"\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p991120443183503\"\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li2005701407183503\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p772740490183503\"\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p1853850632183503\"\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p1462631451183503\"\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWith cable management frames (15 U high): 663.9 mm x 442 mm x 585 mm (26.1 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWithout cable management frames (15 U high): 663.9 mm x 442 mm x 517.4 mm (26.1 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e25 kg\/97 kg (55.1 lb\/213.8 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMTBF: 24.1 years\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p204769567183503\"\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li221157362183503\"\u003eOperating temperature and altitude:\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p491897288183503\"\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p552208305183503\"\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_p468791767183503\"\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li314421553183503\"\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1846036463183503\"\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li878094327183503\"\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li273946044183503\"\u003eEMC certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1805335276183503\"\u003eSafety certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\" id=\"EN-US_CONCEPT_0177093134__EN-US_CONCEPT_0177093134_mMcCpPsS_en-us_concept_0177092964_li1915639674183503\"\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\"\u003e\n\u003cdiv class=\"idp-ltr-html-p\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS7712 chassis: 02113306\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS7712 chassis, PoE supported: 02113308\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS7712 chassis, FCC certified: 02113961\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS7712 chassis, PoE supported, FCC certified: 02113963\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many slots does the Huawei S7712 have and what interface cards are compatible?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 12 service slots + 2 control slots + 2 power slots—compatible with all Huawei S7700 series interface cards (10G\/1G SFP+\/SFP\/RJ45\/Combo).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the redundancy features of the Huawei S7712?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Dual control board (1+1), dual power supply (1+1), fan redundancy—0ms failover, ensuring non-stop critical business operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the switching capacity and packet forwarding rate of the S7712?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Switching capacity ≥7.2Tbps (expandable to 14.4Tbps), packet forwarding rate ≥5400Mpps—line-speed forwarding for all ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is the Huawei S7712 suitable for financial core transaction networks?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! With high reliability (MTBF ≥1.2M hours), low latency, and MPLS VPN isolation—it’s a preferred choice for financial critical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What management systems does the Huawei S7712 support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports CLI\/Web\/iMaster NCE unified management + AI operation and maintenance—simplifies large-scale network management.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46891111219352,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S7712-1.jpg?v=1755066935"},{"product_id":"huawei-s9703-switch","title":"Huawei S9703 Switch","description":"\u003ch4\u003eS9703 Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eS9700 series terabit routing switches (S9700 for short), high-end switches designed for nextgeneration campus networks and data centers, to implement service aggregation. Based on Huawei Versatile Routing Platform (VRP), S9700 provides high L2\/L3 switching capabilities and integrates diversified services such as MPLS VPN, hardware IPv6, desktop cloud, video conferencing, and wireless access. In addition, S9700 also provides various reliability technologies including in-service software upgrade, non-stop forwarding, hardware OAM\/BFD, and ring network protection. These technologies improve customers’ network operation efficiency, maximize the device running time, and reduce customers’ total cost of ownership (TCO).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe S9703 chassis is 4 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions are 442 mm x 489 mm x 175 mm (W x D x H). When the chassis has cable management frames installed, the dimensions are 442 mm x 585 mm x 175 mm (W x D x H).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei S9703 AC bundle including assembly chassis EH1BS9703E00\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2xMCUA Main Board\u003c\/li\u003e\n\u003cli\u003e2x800W AC power module\u003c\/li\u003e\n\u003cli\u003eWith 3 service slots.\u003c\/li\u003e\n\u003cli\u003eForwarding perfomance: 2160Mpps\u003c\/li\u003e\n\u003cli\u003eSwitching capacity: 2.88\/5.76Tbps\u003c\/li\u003e\n\u003cli\u003eNon-POE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9703_chassis.png?v=1755579762\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-simpletableborder\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e1. Three of the following service cards can be installed:\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Hardware Query Tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3. A pair of mounting brackets\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e4. Two power modules\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5. Reserved slot\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e6. Front ESD jack\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e7. Cable management frames\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" summary=\"\" class=\"idp-ltr-html-tb-normal\" id=\"chassis_9303E__chassis_9303E_mMcCpPsS_tab_dc_s_hw_09061201\" border=\"1\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9303E__chassis_9303E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9303E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9303E__chassis_9303E_mMcCpPsS_port1\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R001C00: 144xFE, 144xGE, 120x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R002C00 and V200R003C00: 144xFE, 144xGE, 120x10GE, 24x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R005C00 to V200R007C10: 144xFE, 144xGE, 144x10GE, 24x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R008C00 to V200R009C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 6x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R010C00 to V200R013C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eIn an N66E or N68E cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMaximum power consumption (fully loaded)\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e1185 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9303E__ul_dc_s_hw_09061201\"\u003e\u003c\/a\u003e\u003ca name=\"ul_dc_s_hw_09061201\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9303E__ul_dc_s_hw_09061201\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -40 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eDimensions (W x D x H, excluding rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9303E__ul_dc_s_hw_09061205\"\u003e\u003c\/a\u003e\u003ca name=\"ul_dc_s_hw_09061205\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9303E__ul_dc_s_hw_09061205\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWith cable management frames: 442 mm x 585 mm x 175 mm (17.4 in. x 23.0 in. x 6.89 in. (4 U))\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWithout cable management frames: 442 mm x 489 mm x 175 mm (17.4 in. x 19.3 in. x 6.89 in. (4 U))\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eWeight (empty\/fully loaded)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e\u003cspan id=\"chassis_9303E__ph_dc_s_hw_09061213\"\u003e\u003ca name=\"chassis_9303E__ph_dc_s_hw_09061213\"\u003e\u003c\/a\u003e\u003ca name=\"ph_dc_s_hw_09061213\"\u003e\u003c\/a\u003e11 kg\/32.6 kg (24.3 lb\/71.9 lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time between failures (MTBF): 33.8 years\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time to repair (MTTR): 64 minutes\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAvailability: 0.9999964\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\" id=\"chassis_9303E__note_section6_01\"\u003e\n\u003ca name=\"chassis_9303E__note_section6_01\"\u003e\u003c\/a\u003e\u003ca name=\"note_section6_01\"\u003e\u003c\/a\u003e\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9303E__ul_dc_s_hw_09059402\"\u003e\u003c\/a\u003e\u003ca name=\"ul_dc_s_hw_09059402\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9303E__ul_dc_s_hw_09059402\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cp id=\"chassis_9303E__chassis_9303E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003ca name=\"chassis_9303E__chassis_9303E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9303E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eEMC certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eSafety certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.7.5.6.2.2.3.1.2\"\u003e\n\u003cdiv class=\"idp-ltr-html-p\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9703 chassis: 02113547\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9703 chassis, FCC certified: 02113611\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many interface cards can Huawei S9703 support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 3 business slots—supports all Huawei S9700 series copper\/optical\/hybrid interface cards for lightweight deployment in county government scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the reliability level (MTBF) of Huawei S9703?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Industrial-grade basic reliability with MTBF ≥ 950,000 hours—ideal for 7×24 critical services like county gov approval \u0026amp; rural medical treatment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does Huawei S9703 support redundant power supply and fans?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes—lightweight redundancy for power supply\/fans with hot-swappable design, no service interruption during module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46906255311000,"sku":"02113547","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9703-1.jpg?v=1755579901"},{"product_id":"huawei-s9706-switch","title":"Huawei S9706 Switch","description":"\u003ch4\u003eS9706 Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eS9700 series terabit routing switches (S9700 for short), high-end switches designed for nextgeneration campus networks and data centers, to implement service aggregation. Based on Huawei Versatile Routing Platform (VRP), S9700 provides high L2\/L3 switching capabilities and integrates diversified services such as MPLS VPN, hardware IPv6, desktop cloud, video conferencing, and wireless access. In addition, S9700 also provides various reliability technologies including in-service software upgrade, non-stop forwarding, hardware OAM\/BFD, and ring network protection. These technologies improve customers’ network operation efficiency, maximize the device running time, and reduce customers’ total cost of ownership (TCO).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eS9706\u003c\/span\u003e\u003cspan\u003e chassis is 10 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions are 442 mm x 489 mm x 441.7 mm (W x D x H). When the chassis has cable management frames installed, the dimensions are 442 mm x 585 mm x 441.7 mm (W x D x H). \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei S9706 AC bundle including assembly chassis EH1BS9706E00\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2xSRUD Main Board, 2x800W AC power module\u003c\/li\u003e\n\u003cli\u003eWith 6 service slots\u003c\/li\u003e\n\u003cli\u003eForwarding perfomance: 2880\/5040Mpps\u003c\/li\u003e\n\u003cli\u003eSwitching capacity: 6.72\/14.72Tbps\u003c\/li\u003e\n\u003cli\u003eNon-POE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9706_chassis.png?v=1755580279\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" class=\"idp-ltr-html-simpletableborder\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e1. Six of the following service cards can be installed:\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Hardware Query Tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3. A pair of mounting brackets\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e4. Four power modules\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5. Two EH1D200CMU00-Centralized Monitoring Unit\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6. Reserved slot\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e7. Front ESD jack\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e8. Cable management frames\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" summary=\"\" class=\"idp-ltr-html-tb-normal\" id=\"chassis_9306E__chassis_9306E_mMcCpPsS_tab_dc_s_hw_09061201\" border=\"1\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" id=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9306E__chassis_9306E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9306E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9306E__chassis_9306E_mMcCpPsS_port1\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R001C00: 288xFE, 288xGE, 240x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R002C00 and V200R003C00: 288xFE, 288xGE, 240x10GE, 48x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R005C00 to V200R007C10: 288xFE, 288xGE, 288x10GE, 48x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R008C00 to V200R009C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 12x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R010C00 to V200R013C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one or two chassis in a cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003eService port\u003cspan\u003e or CSS card\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eclustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eMaximum power consumption (fully loaded)\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e2640 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -40 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eDimensions (W x D x H, excluding rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003ca name=\"chassis_9306E__ul_dc_s_hw_09061805\"\u003e\u003c\/a\u003e\u003ca name=\"ul_dc_s_hw_09061805\"\u003e\u003c\/a\u003e\n\u003cul class=\"idp-ltr-html-ul\" id=\"chassis_9306E__ul_dc_s_hw_09061805\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWith cable management frames: 442 mm x 585 mm x 441.7 mm (17.4 in. x 23.0 in. x 17.39 in. (10 U))\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWithout cable management frames: 442 mm x 489 mm x 441.7 mm (17.4 in. x 19.3 in. x 17.39 in. (10 U))\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eWeight (empty\/fully loaded)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp\u003e\u003cspan id=\"chassis_9306E__ph_dc_s_hw_09061813\"\u003e\u003ca name=\"chassis_9306E__ph_dc_s_hw_09061813\"\u003e\u003c\/a\u003e\u003ca name=\"ph_dc_s_hw_09061813\"\u003e\u003c\/a\u003e29 kg\/75.8 kg (63.9 lb\/167.1 lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time between failures (MTBF): 24.2 years\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time to repair (MTTR): 52 minutes\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cp id=\"chassis_9306E__chassis_9306E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003ca name=\"chassis_9306E__chassis_9306E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9306E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eEMC certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eSafety certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.1\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"50%\" headers=\"mcps1.7.8.5.6.2.2.3.1.2\"\u003e\n\u003cdiv class=\"idp-ltr-html-p\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9706 chassis: 02113548\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9706 chassis, FCC certified: 02113612\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many interface cards can Huawei S9706 support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 6 business slots—supports all Huawei S9700 series copper\/optical\/hybrid interface cards for high-density deployment in municipal government core scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the reliability level (MTBF) of Huawei S9706?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Military-grade basic reliability with MTBF ≥ 1.15 million hours—ideal for 7×24 critical services like municipal gov approval \u0026amp; financial trading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does Huawei S9706 support redundant power supply and fans?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes—full redundancy for power supply\/fans with hot-swappable design, no service interruption during module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46906266845336,"sku":"02113548","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9706-1.jpg?v=1755581291"},{"product_id":"huawei-s9712-switch","title":"Huawei S9712 Switch","description":"\u003ch4\u003eS9712 Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eS9700 series terabit routing switches (S9700 for short), high-end switches designed for nextgeneration campus networks and data centers, to implement service aggregation. Based on Huawei Versatile Routing Platform (VRP), S9700 provides high L2\/L3 switching capabilities and integrates diversified services such as MPLS VPN, hardware IPv6, desktop cloud, video conferencing, and wireless access. In addition, S9700 also provides various reliability technologies including in-service software upgrade, non-stop forwarding, hardware OAM\/BFD, and ring network protection. These technologies improve customers’ network operation efficiency, maximize the device running time, and reduce customers’ total cost of ownership (TCO).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eS9712\u003c\/span\u003e\u003cspan\u003e chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions are 442 mm x 489 mm x 663.95 mm (W x D x H). When the chassis has cable management frames installed, the dimensions are 442 mm x 585 mm x 663.95 mm (W x D x H).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei S9712 AC bundle including assembly chassis EH1BS9712E00\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2xSRUD Main Board, 2x800W AC power module\u003c\/li\u003e\n\u003cli\u003eWith 12 service slots\u003c\/li\u003e\n\u003cli\u003eForwarding perfomance: 2880Mpps\u003c\/li\u003e\n\u003cli\u003eSwitching capacity: 3.84Tbps\u003c\/li\u003e\n\u003cli\u003eNon-POE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9712_chassis.png?v=1755580987\"\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" class=\"idp-ltr-html-simpletableborder\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e1. Twelve of the following service cards can be installed:\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOpen Service Platform Unit\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Hardware Query Tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2. Two MPUs\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3. A pair of mounting brackets\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e4. Six power modules\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5. Two EH1D200CMU00-Centralized Monitoring Unit\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6. Reserved slot\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e7. Front ESD jack\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e8. Cable management frames\n\u003cdiv class=\"idp-ltr-html-note\"\u003eNOTE:\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\" id=\"chassis_9312E__chassis_9312E_mMcCpPsS_tab_dc_s_hw_09061201\" class=\"idp-ltr-html-tb-normal\" summary=\"\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr\u003e\n\u003cth id=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth id=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003ca name=\"chassis_9312E__chassis_9312E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9312E_mMcCpPsS_port1\"\u003e\u003c\/a\u003e\n\u003cul id=\"chassis_9312E__chassis_9312E_mMcCpPsS_port1\" class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R001C00: 576xFE, 576xGE, 480x10GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R002C00 and V200R003C00: 576xFE, 576xGE, 480x10GE, 96x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R005C00 to V200R007C10: 576xFE, 576xGE, 576x10GE, 96x40GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R008C00 to V200R009C00: 576xFE, 576xGE, 576x10GE, 96x40GE, 24x100GE\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eV200R010C00 to V200R013C00: 576xFE, 576xGE, 576x10GE, 96x40GE, 48x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one cabinet for one chassis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eService port\u003cspan\u003e or CSS card\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eclustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eMaximum power consumption (fully loaded)\u003c\/p\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e4906 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -40 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eDimensions (W x D x H, excluding rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003ca name=\"chassis_9312E__ul_dc_s_hw_09062405\"\u003e\u003c\/a\u003e\u003ca name=\"ul_dc_s_hw_09062405\"\u003e\u003c\/a\u003e\n\u003cul id=\"chassis_9312E__ul_dc_s_hw_09062405\" class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWith cable management frames: 442 mm x 585 mm x 663.95 mm (17.4 in. x 23.0 in. x 26.1 in. (15 U))\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eWithout cable management frames: 442 mm x 489 mm x 663.95 mm (17.4 in. x 19.3 in. x 26.1 in. (15 U))\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eWeight (empty\/fully loaded)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003e\u003cspan id=\"chassis_9312E__ph_dc_s_hw_09062413\"\u003e\u003ca name=\"chassis_9312E__ph_dc_s_hw_09062413\"\u003e\u003c\/a\u003e\u003ca name=\"ph_dc_s_hw_09062413\"\u003e\u003c\/a\u003e37 kg\/116 kg (81.6 lb\/255.7 lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time between failures (MTBF): 24.1 years\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eMean time to repair (MTTR): 52 minutes\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"idp-ltr-html-note\"\u003e\n\u003cspan class=\"idp-ltr-html-notetitle\"\u003eNOTE:\u003c\/span\u003e\n\u003cdiv class=\"idp-ltr-html-notebody\"\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eOperating relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eStorage relative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"chassis_9312E__chassis_9312E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003ca name=\"chassis_9312E__chassis_9312E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e\u003ca name=\"chassis_9312E_mMcCpPsS_p_dc_s_hw_09059414\"\u003e\u003c\/a\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eEMC certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eSafety certification\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.1\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.9.5.6.2.2.3.1.2\" width=\"50%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cdiv class=\"idp-ltr-html-p\"\u003e\n\u003cul class=\"idp-ltr-html-ul\"\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9712 chassis: 02113549\u003c\/li\u003e\n\u003cli class=\"idp-ltr-html-li\"\u003eS9712 chassis, FCC certified: 02113613\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many interface cards can Huawei S9712 support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 12 business slots—supports all Huawei S9700 series copper\/optical\/hybrid interface cards for ultra-high density deployment in provincial government core scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the reliability level (MTBF) of Huawei S9712?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enhanced military-grade reliability with MTBF ≥ 1.2 million hours—ideal for 7×24 critical services like provincial gov approval \u0026amp; financial trading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does Huawei S9712 support redundant power supply and fans?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes—full redundancy for power supply\/fans with hot-swappable design, no service interruption during module replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":46906269008024,"sku":"02113549","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9712-1.jpg?v=1755581068"},{"product_id":"huawei-s9303-switch","title":"Huawei S9303 Switch","description":"\u003ch5\u003eS9303 Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9303 support 3 LPU slots, 2 MCU slots, 2 system power supply slots, and 1 PoE power supply slot.\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cstrong\u003eApperance of\u003c\/strong\u003e the\u003cspan\u003e \u003c\/span\u003eS9303\u003c\/h5\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003cbr\u003e\u003cimg class=\"\" src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9303.png?x-oss-process=image\/format,webp\/quality,q_100\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Three of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Two power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. One PoE power modules\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9303 slot configuration\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT4 and SLOT5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe two MCUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT1 to SLOT3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 and PWR2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9303\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV100R006C00 and V200R001C00: 144xFE, 144xGE, 120x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 to V200R007C00: 144xFE, 144xGE, 120x10GE, 6x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 144xFE, 144xGE, 120x10GE, 6x40GE, 6x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R019C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 144xFE, 144xGE, 144x10GE, 24x40GE, 18x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 and later versions: 144xFE, 144xGE, 144x10GE, 36x40GE, 18x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply and 3000 W high-voltage DC power supply\u003c\/li\u003e\n\u003cli\u003ePoE power module backup: no backup\u003c\/li\u003e\n\u003cli\u003eMaximum output power: 3000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1000 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv\u003eMaximum voltage range:\n\u003cul\u003e\n\u003cli\u003e1600 W\/2400 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (4 U high): 175 mm x 442 mm x 585 mm (6.9 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (4 U high): 175 mm x 442 mm x 517.4 mm (6.9 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 kg\/31.6 kg (22.0 lb\/69.7 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean time between failures (MTBF): 33.8 years\u003c\/li\u003e\n\u003cli\u003eMean time to repair (MTTR): 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999964\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02113089\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9303 switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 3 service slots, supporting Gigabit\/10G interface cards for flexible deployment in small-medium scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9303 switch support redundant deployment and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features power\/fan N+1 redundancy and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9303?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥16Tbps switching capacity and ≥6000Mpps packet forwarding rate, meeting small-medium enterprise core needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9303 suitable for chain brand regional store networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—cost-effectiveness, reliability, and dual-mode management make it ideal for branch backbone and small-medium campus core deployment.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316250460312,"sku":"02113089","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9303.png?v=1760593462"},{"product_id":"huawei-s9306-switch","title":"Huawei S9306 Switch","description":"\u003ch5\u003eS9306\u003cstrong\u003e \u003c\/strong\u003eHardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9303 support 2* Switching and Routing Units (SRUs), 6* LPUs, and AC or DC power modules in 1+1 or 2+2 backup mode.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe S9306 chassis is 10 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 441.7 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 441.7 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9306\u003c\/h5\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9306.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Six of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Four power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Two LE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Four PoE power modules\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Ground screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground screw is used to ground the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9306 slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT7 and SLOT8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe SRUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT1 to SLOT6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU1 and CMU2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe CMUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 to PWR4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE1 to PoE4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1, FAN2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S930\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV100R006C00 and V200R001C00: 288xFE, 288xGE, 240x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 to V200R007C00: 288xFE, 288xGE, 240x10GE, 12x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 288xFE, 288xGE, 240x10GE, 12x40GE, 12x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R019C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 288xFE, 288xGE, 288x10GE, 48x40GE, 36x100GE\u003c\/li\u003e\n\u003cli\u003eV200R021C00 and later versions: 288xFE, 288xGE, 288x10GE, 72x40GE, 36x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one or two chassis in a cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS card or service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply and 3000 W high-voltage DC power supply\u003c\/li\u003e\n\u003cli\u003ePoE power module backup: no backup, 3+1 backup, or 2+2 backup\u003c\/li\u003e\n\u003cli\u003eMaximum output power: 9000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2200 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv\u003eMaximum voltage range:\n\u003cul\u003e\n\u003cli\u003e1600 W\/2400 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (10 U high): 441.7 mm x 442 mm x 585 mm (17.39 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (10 U high): 441.7 mm x 442 mm x 517.4 mm (17.39 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 kg\/61.8 kg (33.1 lb\/136.2 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMTBF: 24.2 years\u003c\/li\u003e\n\u003cli\u003eMTTR: 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eS9306 chassis: 02113090\u003c\/li\u003e\n\u003cli\u003eS9306 chassis, PoE supported: 02113196\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9306 switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 6 service slots, supporting 10G\/40G interface cards for flexible multi-service deployment in mid-large scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9306 switch support redundant deployment and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features switch fabric\/power\/fan redundancy and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9306?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥32Tbps switching capacity and ≥12000Mpps packet forwarding rate, meeting mid-large campus\/data center needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9306 suitable for regional medical group backbone networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—high reliability, cost-effectiveness, and stable performance make it ideal for mid-large enterprise core\/aggregation deployment.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316254359704,"sku":"02113090","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9306.png?v=1760594041"},{"product_id":"huawei-s9310-switch","title":"Huawei S9310 Switch","description":"\u003ch5\u003eS9310 Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9310 support 2* SRUs, 10* LPUs, and AC or DC power modules in N+N\/N+1\/N+0 (no redundancy) backup mode.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eThe S9310 chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9310\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9310.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Ten LPUs, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two SRUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Four power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Two CMUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8. Two LE1D2SFUK000-S9310 Switch Fabric Unit Ks\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9310 slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlot 13, slot 14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSRUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo MPUs in the slots work in hot standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSFU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlot 11, slot 12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLE1D2SFUK000-S9310 Switch Fabric Unit K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlots 1 to 10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU1, CMU2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo CMUs in the slots work in hot standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 to PWR4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA non-power slot has been installed with a filler panel and cannot be installed with a power module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1 to FAN4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9310\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of LPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of MPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of SFU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of fan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNumber of power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R010C00 and V200R011C10: 480xFE, 480xGE, 480x10GE, 80x40GE, 40x100GE\u003c\/li\u003e\n\u003cli\u003eV200R012C00 and later versions: 480xFE, 480xGE, 480x10GE, 160x40GE, 80x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one cabinet for one chassis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports CSS card clustering (CSS cards integrated on main control unit and SFU, with fixed CSS ports on panels) and service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4644 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC to -60 V DC\u003c\/p\u003e\n\u003cdiv\u003eMaximum voltage range:\n\u003cul\u003e\n\u003cli\u003e2400 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The maximum output power reduces by a half when the input voltage ranges from 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (15 U high): 663.9 mm x 442 mm x 585 mm (26.1 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (15 U high): 663.9 mm x 442 mm x 517.4 mm (26.1 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e28.6 kg\/98.4 kg (63.05 lb\/216.93 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean Time Between Failures (MTBF): 40.04 years\u003c\/li\u003e\n\u003cli\u003eMean time to repair (MTTR): 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999984\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 75.7 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02114861\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9310 switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 10 service slots, supporting 10G\/40G interface cards for flexible multi-service deployment in large scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9310 switch support full redundancy and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features switch fabric\/power\/fan full redundancy and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9310?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥44.8Tbps switching capacity and ≥16800Mpps packet forwarding rate, meeting large campus\/data center needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9310 suitable for large manufacturing group core production network?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—high performance, full redundancy, and smart management make it ideal for mission-critical industrial scenarios.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316254949528,"sku":"02114861","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9310.png?v=1760594197"},{"product_id":"huawei-s9312-switch","title":"Huawei S9312 Switch","description":"\u003ch5\u003eS9312 Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9312 support 2* SRUs, 12* LPUs, and AC or DC power modules in 1+1 or 2+2 backup mode.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eThe S9312 chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9312\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9312.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Twelve of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Four power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Two LE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Four PoE power modules\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eFor details, see Power Module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Ground screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground screw is used to ground the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9312 slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT13 and SLOT14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe SRUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT1 to SLOT12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eValue-Added Service Unit\u003c\/li\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU1 and CMU2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe CMUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 to PWR4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE1 to PoE4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e2200 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e800 W AC Power Module\u003c\/li\u003e\n\u003cli\u003e2200 W DC Power Module (Supported in V200R006C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3000 W AC Power Module (Supported in V200R012C00 and later versions )\u003c\/li\u003e\n\u003cli\u003e3000 W high-voltage DC Power Module (Supported in V200R012C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1 to FAN4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9312\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE power supply slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV100R006C00 and V200R001C00: 576xFE, 576xGE, 480x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 to V200R007C00: 576xFE, 576xGE, 480x10GE, 24x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 576xFE, 576xGE, 480x10GE, 24x40GE, 24x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R019C00: 576xFE, 576xGE, 576x10GE, 96x40GE, 48x100GE\u003c\/li\u003e\n\u003cli\u003eV200R019C00 to V200R020C10: 576xFE, 576xGE, 576x10GE, 96x40GE, 72x100GE\u003c\/li\u003e\n\u003cli\u003eV200R021C00 and later versions: 576xFE, 576xGE, 576x10GE, 144x40GE, 72x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one cabinet for one chassis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS card or service port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePower input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). V200R012C00 and later versions support 3000 W AC power supply and 3000 W high-voltage DC power supply\u003c\/li\u003e\n\u003cli\u003ePoE power module backup: no backup, 3+1 backup, or 2+2 backup\u003c\/li\u003e\n\u003cli\u003eMaximum output power: 9000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured, no PoE power supply)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4200 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cdiv\u003eMaximum voltage range:\n\u003cul\u003e\n\u003cli\u003e1600 W\/2400 W DC power module: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003cli\u003e2200 W DC power module: -40 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (15 U high): 663.9 mm x 442 mm x 585 mm (26.1 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (15 U high): 663.9 mm x 442 mm x 517.4 mm (26.1 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e25 kg\/97 kg (55.1 lb\/213.8 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMTBF: 24.1 years\u003c\/li\u003e\n\u003cli\u003eMTTR: 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eS9312 chassis: 02113091\u003c\/li\u003e\n\u003cli\u003eS9312 chassis, PoE supported: 02113198\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9312 switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 12 service slots, supporting 10G\/40G interface cards for flexible deployment in multi-service mission-critical scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9312 switch support full redundancy and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features full redundancy (switch fabric\/power\/fan) and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9312?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥51.2Tbps switching capacity and ≥19200Mpps packet forwarding rate, meeting high-concurrency core network needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9312 suitable for state-owned bank data center backbone interconnection?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—classic reliability, high performance, and full redundancy make it ideal for mission-critical financial scenarios.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316256325784,"sku":"02113091","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9312.png?v=1760594579"},{"product_id":"huawei-s9303e-switch","title":"Huawei S9303E Switch","description":"\u003ch5\u003eS9303E Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9303E 2* Main Control Units (MCUs), 3* Line Processing Units (LPUs), and AC or DC power modules in N+N\/N+1\/N+0 (no redundancy) backup mode.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eThe S9303E chassis is 4 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 175 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 175 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9303E\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9303E.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Three of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Two power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Reserved slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9303E slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMCU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT04 and SLOT05\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe MCUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT01 to SLOT03\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 and PWR2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9303E\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R001C00: 144xFE, 144xGE, 120x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 and V200R003C00: 144xFE, 144xGE, 120x10GE, 6x40GE\u003c\/li\u003e\n\u003cli\u003eV200R005C00, V200R006C00 and V200R007C00: 144xFE, 144xGE, 144x10GE, 6x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 144xFE, 144xGE, 144x10GE, 6x40GE, 6x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R013C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1185 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (4 U high): 175 mm x 442 mm x 585 mm (6.9 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (4 U high): 175 mm x 442 mm x 517.4 mm (6.9 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e11 kg\/32.6 kg (24.3 lb\/71.9 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean time between failures (MTBF): 33.8 years\u003c\/li\u003e\n\u003cli\u003eMean time to repair (MTTR): 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999964\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02113477\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9303E switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 3 service slots, supporting Gigabit\/10G interface cards for flexible deployment in small-medium scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9303E switch support redundant deployment and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features power\/fan N+1 redundancy and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9303E?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥19.2Tbps switching capacity and ≥7200Mpps packet forwarding rate, meeting small-medium enterprise core needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9303E suitable for chain brand regional branch networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—cost-effectiveness, reliability, and easy management make it ideal for branch backbone and small-medium campus core deployment.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316258554008,"sku":"02113477","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9303E.png?v=1760594845"},{"product_id":"huawei-s9306e-switch","title":"Huawei S9306E Switch","description":"\u003ch5\u003eS9306E Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9306E 2* Switching and Routing Units (SRUs), 6* LPUs, and AC or DC power modules in N+N\/N+1\/N+0 (no redundancy) backup mode.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eThe S9306E chassis is 10 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 441.7 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 441.7 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9306E\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9306E.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Six of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Four power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Two LE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Reserved slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9306E slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT07 and SLOT08\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe SRUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT01 to SLOT06\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 to PWR4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU1 and CMU2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLE0DCMUA0000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe CMUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1, FAN2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9306E\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R001C00: 288xFE, 288xGE, 240x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 and V200R003C00: 288xFE, 288xGE, 240x10GE, 12x40GE\u003c\/li\u003e\n\u003cli\u003eV200R005C00, V200R006C00 and V200R007C00: 288xFE, 288xGE, 288x10GE, 12x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 288xFE, 288xGE, 288x10GE, 12x40GE, 12x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R013C00: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one or two chassis in a cabinet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eService port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2640 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (10 U high): 441.7 mm x 442 mm x 585 mm (17.39 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (10 U high): 441.7 mm x 442 mm x 517.4 mm (17.39 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e29 kg\/75.8 kg (63.9 lb\/167.1 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean time between failures (MTBF): 24.2 years\u003c\/li\u003e\n\u003cli\u003eMean time to repair (MTTR): 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02113478\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9306E switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 6 service slots, supporting 10G\/40G interface cards for flexible multi-service deployment in mid-large scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9306E switch support redundant deployment and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features switch fabric\/power\/fan redundancy and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9306E?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥38.4Tbps switching capacity and ≥14400Mpps packet forwarding rate, meeting mid-large campus\/data center needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9306E suitable for regional manufacturing group backbone networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—high performance, cost-effectiveness, and reliability make it ideal for regional enterprise core\/aggregation deployment.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316260192408,"sku":"02113478","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9306E.png?v=1760595015"},{"product_id":"huawei-s9312e-switch","title":"Huawei S9312E Switch","description":"\u003ch5\u003eS9312E Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series Switch S9312E 2* SRUs, 12* LPUs, and AC or DC power modules in N+N\/N+1\/N+0 (no redundancy) backup mode\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eThe S9312E chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 585 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eApperance of the S9312E\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/S9312E.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. Twelve of the following service cards can be installed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Two MPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. A pair of mounting brackets\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe mounting brackets are used to secure the chassis in the cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. Six power modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. Two LE0DCMUA0000-Centralized Monitoring Unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Reserved slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eInstall a filler panel in the reserved slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. Front ESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8. Cable management frames\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eCable management frames are used to route cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eS9312E slot configuration\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eSlot Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSlot ID\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eModule Supported\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRemarks\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT13 and SLOT14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPUs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe SRUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSLOT01 to SLOT12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e100M Interface Card\u003c\/li\u003e\n\u003cli\u003e1000M Interface Card\u003c\/li\u003e\n\u003cli\u003eGE\/10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e10GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE Interface Card\u003c\/li\u003e\n\u003cli\u003e40GE\/100GE Interface Card\u003c\/li\u003e\n\u003cli\u003e100GE Interface Card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe cards supported by a switch depend on the software version. For details, see Info-Finder.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePWR1 to PWR6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epower modules\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCMU1 and CMU2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLE0DCMUA0000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe CMUs work in active\/standby mode.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFAN1 to FAN4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan Module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S9312E\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLPU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMCU slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower slots\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum port density\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eV200R001C00: 576xFE, 576xGE, 480x10GE\u003c\/li\u003e\n\u003cli\u003eV200R002C00 and V200R003C00: 576xFE, 576xGE, 480x10GE, 24x40GE\u003c\/li\u003e\n\u003cli\u003eV200R005C00, V200R006C00 and V200R007C00: 576xFE, 576xGE, 576x10GE, 24x40GE\u003c\/li\u003e\n\u003cli\u003eV200R008C00 to V200R009C00: 576xFE, 576xGE, 576x10GE, 24x40GE, 24x100GE\u003c\/li\u003e\n\u003cli\u003eV200R010C00 to V200R013C00: 576xFE, 576xGE, 576x10GE, 96x40GE, 48x100GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInstallation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIn an N66E or N68E cabinet, one cabinet for one chassis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCSS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eService port clustering\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (fully configured)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe heat dissipation value of a chassis equals the current power consumption of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4906 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDC input voltage\n\u003cp\u003eRated voltage: -48 V DC\/-60 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: -38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eAC input voltage\n\u003cp\u003eRated voltage: 110 V AC\/220 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W AC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 290 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVDC input voltage (3000 W HVDC)\u003c\/p\u003e\n\u003cp\u003eRated voltage: 240 V DC\/ 380 V DC\u003c\/p\u003e\n\u003cp\u003eMaximum voltage range: 190 V DC to 400 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (W x D x H, without rack-mounting brackets)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWith cable management frames (15 U high): 663.9 mm x 442 mm x 585 mm (26.1 in. x 17.4 in. x 23.0 in.)\u003c\/li\u003e\n\u003cli\u003eWithout cable management frames (15 U high): 663.9 mm x 442 mm x 517.4 mm (26.1 in. x 17.4 in. x 20.37 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (empty\/fully configured)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e37 kg\/116 kg (81.6 lb\/255.7 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReliability and availability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMean time between failures (MTBF): 24.1 years\u003c\/li\u003e\n\u003cli\u003eMean time to repair (MTTR): 2 hours\u003c\/li\u003e\n\u003cli\u003eAvailability: 0.9999959\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eEnvironment specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature and altitude:\n\u003cp\u003e-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)\u003c\/p\u003e\n\u003cp\u003e1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003e4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5% RH to 95% RH (noncondensing)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003eStorage altitude: \u0026lt; 5000 m (16404 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise at normal temperature (acoustic power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e≤ 72 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02113479\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many slots does the Huawei S9312E switch have, and what interfaces does it support?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It has 12 service slots, supporting 10G\/40G interface cards for flexible deployment in multi-service scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S9312E switch support redundant deployment and IPv6?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it features full redundancy (switch fabric\/power\/fan) and native IPv6 dual-stack support for next-gen network upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the switching capacity and packet forwarding rate of the S9312E?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers ≥57.6Tbps switching capacity and ≥21600Mpps packet forwarding rate, meeting high-concurrency core network needs.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the Huawei S9312E suitable for financial data center backbone interconnection?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—high performance, full redundancy, and low latency make it ideal for mission-critical scenarios like financial services.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316261404824,"sku":"02113479","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S9312E.png?v=1760595148"},{"product_id":"huawei-le0mpsd16-power-module","title":"Huawei LE0MPSD16 Power Module","description":"\u003ch5\u003eLE0MPSD16 Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S9300 Series LE0MPSD16 1600 W DC Power Module.\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003ePanel of the LE0MPSD16\u003cstrong\u003e\u003cbr\u003e\u003cimg class=\"\" src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/19\/photo\/PaneloftheLE0MPSD16.png?x-oss-process=image\/format,webp\/quality,q_100\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1. NEG terminal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2. Power switch\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eON: The power module is supplying power.\u003c\/li\u003e\n\u003cli\u003eOFF: The power module is not supplying power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3. ALARM indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e4. OUTPUT indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5. INPUT indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6. Ejector lever\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eRaise the ejector lever to release the power module from the slot, and lower the ejector lever to lock the power module in the slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7. RTN terminal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e—\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e—\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\n\u003cbr\u003e\u003cstrong\u003eRelationship between cables and the terminals on a 1600 W DC power module\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eInput Terminal Identifier\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eCable Type\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eCable Color\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eConnected Terminal\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTN\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eRTN indicates return.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower ground cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBlack\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp\u003eOT bare crimp terminal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNEG\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBlue\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cbr\u003eIndicators on the LE0MPSD16\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSilkscreen\u003c\/th\u003e\n\u003cth\u003eName\u003c\/th\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003cth\u003eStatus\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eINPUT\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eINPUT indicator\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eSteady off\u003c\/td\u003e\n\u003ctd\u003eThe power module receives no power input or its power cables are reversely connected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003eSteady on\u003c\/td\u003e\n\u003ctd\u003eThe input power is normal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOUTPUT\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eOUTPUT indicator\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eSteady off\u003c\/td\u003e\n\u003ctd\u003eThe power module provides no output power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003eSteady on\u003c\/td\u003e\n\u003ctd\u003eThe output power of the power module is in the normal range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eALARM\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eALARM indicator\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eSteady off\u003c\/td\u003e\n\u003ctd\u003eThe protection circuit is working properly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eSteady on\u003c\/td\u003e\n\u003ctd\u003eThe protection circuit has failed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eFunctions and Features\u003c\/h5\u003e\n\u003cp\u003eA 1600 W DC power module provides a maximum of 1600 W power for the chassis and has the following functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003cli\u003eAlarms about various power supply events, for example, no external power input, input undervoltage, and power switch off.\u003c\/li\u003e\n\u003cli\u003eThe power module is hot swappable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e130 mm x 41 mm x 393 mm (5.1 in. x 1.6 in. x 15.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd\u003e-48 V DC to -60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd\u003e-38.4 V DC to -72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current [A]\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output voltage [V]\u003c\/td\u003e\n\u003ctd\u003e53.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current [A]\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output power [W]\u003c\/td\u003e\n\u003ctd\u003e1600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot swapping\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Which S9300 chassis models is the LE0MPSD16 compatible with?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Fully compatible with Huawei S9303 and their E-series chassis—plug-and-play for startup\/branch low-cost upgrades.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the LE0MPSD16 support redundant deployment and easy installation?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—it supports basic N+1 redundancy for uninterrupted power and plug-and-play design for hassle-free setup.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the output power and conversion efficiency of the LE0MPSD16?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It delivers 1600W rated power and ≥90% conversion efficiency (typical load), balancing performance and energy saving.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the LE0MPSD16 suitable for startup companies with limited budget?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—cost-effectiveness, easy installation, and basic reliability make it ideal for startups and small branches.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47316262617240,"sku":"02316867","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/LE0MPSD16.png?v=1760595399"},{"product_id":"huawei-s16700-4-switch","title":"Huawei S16700-4 Switch","description":"\u003ch5\u003eS16700-4 Hardware Description\u003c\/h5\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eIntroduction\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\u003cspan\u003eSeries switches CloudEngine S16700 is an advanced core device with exceptional performance designed for efficient 10-Gigabit enterprise networks. This series features ultra-high throughput at the level of 14,4 Tbit\/with in every slot, unrivaled switching hardware and wide access to terminals. One of the key features CloudEngine S16700 is pioneering the use of channel grouping technology between chassis (M-LAG) in corporate networks, providing a level of reliability at an amazing level 99,9999%.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eIn addition, this series has other attractive features such as virtual advanced local area networks (VXLAN), providing flexibility and scalability, free mobility for uninterrupted connectivity, quality of service management (QoS) to optimize data transfer, the algorithm for storing packets for the Internet ( iPCA), providing efficient use of network resources. Users can enjoy the ability to deploy a service in one click and quickly localize failures at the level of minutes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eWith these advanced features, CloudEngine S16700 becomes the ideal choice for global customers preparing for a new era of corporate networks with astonishing throughput at the level 400 Gbit\/with. This device goes beyond a simple switch to provide comprehensive solutions for today's networking requirements.\u003c\/span\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eSlots on the S16700-4\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/29\/photo\/S16700-4-1.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSlot Type\u003c\/th\u003e\n\u003cth\u003eSlot ID\u003c\/th\u003e\n\u003cth\u003eSlot Direction\u003c\/th\u003e\n\u003cth\u003eRemarks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPU slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 4\u003c\/td\u003e\n\u003ctd\u003eThe top of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003eDifferent types of LPUs can be installed in the same chassis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU slot\u003c\/td\u003e\n\u003ctd\u003eSlots 5 and 6\u003c\/td\u003e\n\u003ctd\u003eThe top of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo MPUs work in active\/standby mode for 1:1 hot standby.\u003c\/p\u003e\n\u003cp\u003eBy default, the MPU with a smaller slot ID is the active MPU, and the MPU with a larger slot ID is the standby MPU.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFU slot\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlots 1 to 9\u003c\/p\u003e\n\u003cp\u003eNote:\u003c\/p\u003e\n\u003cp\u003eFor the slots in which SFUs can be installed, see the \"IDs of Available Slots\" column in \"Version Mapping\" under \"Cards \u0026gt; SFU\".\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThe right side of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003eSFUs work in load balancing and redundancy mode. SFUs in the same chassis must be the same model. That is, SFUs of different models cannot be installed in the same chassis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 6\u003c\/td\u003e\n\u003ctd\u003eThe indicator light end upwards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePMs are plug-and-play.\u003c\/p\u003e\n\u003cp\u003ePM4 to PM6 in the chassis with the part number 02355HUL-001 are reserved.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan module slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 3\u003c\/td\u003e\n\u003ctd\u003eThe indicator light end upwards\u003c\/td\u003e\n\u003ctd\u003eAt the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S16700-4\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e438 mm x 442 mm x 874 mm (17.24 in. x 17.4 in. x 34.41 in.), dimensions of the chassis body\u003c\/li\u003e\n\u003cli\u003e438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.), including mounting brackets and cable management frames\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd\u003e9.8 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet installation standards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eA610\u003c\/li\u003e\n\u003cli\u003eA612\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL): 94.1 kg (207.45 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001): 94.1 kg (207.45 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM): 98.1 kg (216.27 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging (full configuration) [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL): 162 kg (357.15 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001): 162 kg (357.15 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM): 163.6 kg (360.67 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL): 138 kg (304.23 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001): 138 kg (304.23 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM): 142 kg (313.05 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e4664 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e15914 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd\u003e34.93 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e0.9999971695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of MPU slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of SFU slots\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of service board slots\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPU slot direction\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant MPUs\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Switch fabrics\u003c\/td\u003e\n\u003ctd\u003eN+M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input power supply system: N+1 backup is recommended.\u003c\/li\u003e\n\u003cli\u003eSingle-input power supply system: N+1 backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDual-input power supply is recommended to ensure reliability.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant fans\u003c\/td\u003e\n\u003ctd\u003eFan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003eWhen the altitude is 1800 m to 5000 m (5905.44 ft. to 16404.00 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C (–40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd\u003e5% RH to 85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e≤ 5000 m (16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e≤ 5000 m (16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL):\n\u003cul\u003e\n\u003cli\u003eAC input: 220 V AC; 50 Hz\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\/380 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001):\n\u003cul\u003e\n\u003cli\u003eAC input: 220 V AC; 50 Hz\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\/380 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM): –48 V DC\/–60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL):\n\u003cul\u003e\n\u003cli\u003eAC input: 176 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 188 V DC to 288 V DC\/260 V DC to 400 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001):\n\u003cul\u003e\n\u003cli\u003eAC input: 176 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 188 V DC to 288 V DC\/260 V DC to 400 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM): –40 V DC to –72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd\u003eDrawing air for heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow direction\u003c\/td\u003e\n\u003ctd\u003eFront-to-rear airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power output capability [W]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL):\n\u003cul\u003e\n\u003cli\u003e5+1 backup: 3000 W x 5 = 15000 W\u003c\/li\u003e\n\u003cli\u003e6+0 backup: 3000 W x 6 = 18000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SA0 (02355HUL-001):\n\u003cul\u003e\n\u003cli\u003e2+1 backup: 6000 W (3000 W x 2)\u003c\/li\u003e\n\u003cli\u003e3+0 backup: 9000 W (3000 W x 3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16704SD0 (02355HUM):\n\u003cul\u003e\n\u003cli\u003e5+1 backup: 2200 W x 5 = 11000 W\u003c\/li\u003e\n\u003cli\u003e6+0 backup: 2200 W x 6 = 13200 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the key advantage of the Huawei S16700-4 switch?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It features 14.4T\/s slot throughput, 9.8U compact design, full redundancy—ideal for mid-large network core deployment.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many service slots does the Huawei S16700-4 have?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 4 LPU service slots + multiple module slots, supporting flexible expansion from 10G to 400G.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What redundancy features does the S16700-4 offer?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 1:1 MPU backup, SFU load balancing, N+1 power backup, and fan hot backup—zero single point of failure.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the S16700-4 suitable for small-to-medium sized data centers?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Absolutely—its 9.8U compact design saves 40% cabinet space, fitting space-limited deployment scenarios.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S16700-4 support virtualization and intelligent O\u0026amp;M?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—supports VXLAN\/EVPN\/MPLS virtualization, one-click deployment, and minute-level fault location.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47318181642392,"sku":"02355HUL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S16700-4.jpg?v=1760681563"},{"product_id":"huawei-s16700-8-switch","title":"Huawei S16700-8 Switch","description":"\u003ch5\u003eS16700-8 Hardware Description\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\u003cspan\u003eSeries switches CloudEngine S16700 is an advanced core device with exceptional performance designed for efficient 10-Gigabit enterprise networks. This series features ultra-high throughput at the level of 14,4 Tbit\/with in every slot, unrivaled switching hardware and wide access to terminals. One of the key features CloudEngine S16700 is pioneering the use of channel grouping technology between chassis (M-LAG) in corporate networks, providing a level of reliability at an amazing level 99,9999%.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eIn addition, this series has other attractive features such as virtual advanced local area networks (VXLAN), providing flexibility and scalability, free mobility for uninterrupted connectivity, quality of service management (QoS) to optimize data transfer, the algorithm for storing packets for the Internet ( iPCA), providing efficient use of network resources. Users can enjoy the ability to deploy a service in one click and quickly localize failures at the level of minutes.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eWith these advanced features, CloudEngine S16700 becomes the ideal choice for global customers preparing for a new era of corporate networks with astonishing throughput at the level 400 Gbit\/with. This device goes beyond a simple switch to provide comprehensive solutions for today's networking requirements.\u003c\/span\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eSlots on the S16700-8\u003cstrong\u003e\u003cspan\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ueeshop.ly200-cdn.com\/u_file\/UPBB\/UPBB755\/2509\/29\/photo\/S16700-8.png?x-oss-process=image\/format,webp\/quality,q_100\" class=\"\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSlot Type\u003c\/th\u003e\n\u003cth\u003eSlot ID\u003c\/th\u003e\n\u003cth\u003eSlot Direction\u003c\/th\u003e\n\u003cth\u003eRemarks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPU slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 8\u003c\/td\u003e\n\u003ctd\u003eThe top of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003eDifferent types of LPUs can be installed in the same chassis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU slot\u003c\/td\u003e\n\u003ctd\u003eSlots 9 and 10\u003c\/td\u003e\n\u003ctd\u003eThe top of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo MPUs work in active\/standby mode for 1:1 hot standby.\u003c\/p\u003e\n\u003cp\u003eBy default, the MPU with a smaller slot ID is the active MPU, and the MPU with a larger slot ID is the standby MPU.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFU slot\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlots 1 to 9\u003c\/p\u003e\n\u003cp\u003eNote:\u003c\/p\u003e\n\u003cp\u003eFor the slots in which SFUs can be installed, see the \"IDs of Available Slots\" column in \"Version Mapping\" under \"Cards \u0026gt; SFU\".\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThe right side of the board faces upwards\u003c\/td\u003e\n\u003ctd\u003eSFUs work in load balancing and redundancy mode. SFUs in the same chassis must be the same model. That is, SFUs of different models cannot be installed in the same chassis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 10\u003c\/td\u003e\n\u003ctd\u003eThe indicator light end upwards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePMs are plug-and-play.\u003c\/p\u003e\n\u003cp\u003ePM5 to PM10 in the chassis with the part number 02355HUN-001 are reserved.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan module slot\u003c\/td\u003e\n\u003ctd\u003eSlots 1 to 3\u003c\/td\u003e\n\u003ctd\u003eThe indicator light end upwards\u003c\/td\u003e\n\u003ctd\u003eAt the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch5\u003eTechnical specifications of the S16700-8\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"editor_table_wrap\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e703 mm x 442 mm x 874 mm (27.68 in. x 17.4 in. x 34.41 in.), dimensions of the chassis body\u003c\/li\u003e\n\u003cli\u003e703 mm x 483 mm x 985 mm (27.68 in. x 19.02 in. x 38.78 in.), including mounting brackets and cable management frames\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e990 mm x 770 mm x 1150 mm (38.98 in. x 30.31 in. x 45.28 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd\u003e15.8 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet installation standards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eA610\u003c\/li\u003e\n\u003cli\u003eA612\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN): 129.8 kg (286.16 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001): 129.8 kg (286.16 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP): 135.8 kg (299.38 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging (full configuration) [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN): 253.1 kg (557.98 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001): 253.1 kg (557.98 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP): 255.1 kg (562.39 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN): 177 kg (390.21 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001): 177 kg (390.21 lb)\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP): 183 kg (403.44 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e8260 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e28183 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd\u003e34.55 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e0.9999971582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of MPU slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of SFU slots\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of service board slots\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPU slot direction\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant MPUs\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Switch fabrics\u003c\/td\u003e\n\u003ctd\u003eN+M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input power supply system: N+1 backup is recommended.\u003c\/li\u003e\n\u003cli\u003eSingle-input power supply system: N+1 backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDual-input power supply is recommended to ensure reliability.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant fans\u003c\/td\u003e\n\u003ctd\u003eFan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003eWhen the altitude is 1800 m to 5000 m (5905.44 ft. to 16404.00 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C (–40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd\u003e5% RH to 85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e≤ 5000 m (16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e≤ 5000 m (16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN):\n\u003cul\u003e\n\u003cli\u003eAC input: 220 V AC; 50 Hz\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\/380 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001):\n\u003cul\u003e\n\u003cli\u003eAC input: 220 V AC; 50 Hz\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\/380 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP): –48 V DC\/–60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN):\n\u003cul\u003e\n\u003cli\u003eAC input: 176 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 188 V DC to 288 V DC\/260 V DC to 400 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001):\n\u003cul\u003e\n\u003cli\u003eAC input: 176 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 188 V DC to 288 V DC\/260 V DC to 400 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP): –40 V DC to –72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd\u003eDrawing air for heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow direction\u003c\/td\u003e\n\u003ctd\u003eFront-to-rear airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power output capability [W]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN):\n\u003cul\u003e\n\u003cli\u003e9+1 backup: 3000 W x 9 = 27000 W\u003c\/li\u003e\n\u003cli\u003e10+0 backup: 3000 W x 10 = 30000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SA0 (02355HUN-001):\n\u003cul\u003e\n\u003cli\u003e3+1 backup: 9000 W (3000 W x 3)\u003c\/li\u003e\n\u003cli\u003e4+0 backup: 12000 W (3000 W x 4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEX1BS16708SD0 (02355HUP):\n\u003cul\u003e\n\u003cli\u003e9+1 backup: 2200 W x 9 = 19800 W\u003c\/li\u003e\n\u003cli\u003e10+0 backup: 2200 W x 10 = 22000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What is the key advantage of the Huawei S16700-8 switch?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: It features 14.4T\/s slot throughput, full-module redundancy, 400G support—ideal for ultra-large network core deployment.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: How many service slots does the Huawei S16700-8 have?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 8 LPU service slots + multiple module slots, supporting flexible expansion from 10G to 400G.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: What redundancy features does the S16700-8 offer?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: 1:1 MPU backup, SFU load balancing, N+1 power backup, and fan hot backup—zero single point of failure.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Does the Huawei S16700-8 support virtualization and intelligent O\u0026amp;M?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Yes—supports VXLAN\/EVPN\/MPLS virtualization, one-click deployment, and minute-level fault location.\u003c\/div\u003e\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"auto-hide-last-sibling-br paragraph-pP9ZLC paragraph-element br-paragraph-space\"\u003eQ: Is the S16700-8 suitable for financial core data centers?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\nA: Absolutely—its 99.9997% availability and full redundancy meet the high-reliability requirements of mission-critical scenarios.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":47318187049112,"sku":"02355HUN-001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S16700-8.jpg?v=1760681730"}],"url":"https:\/\/huatelecom.com\/collections\/huawei-data-center-switches.oembed?page=2","provider":"HuaTelecom.com","version":"1.0","type":"link"}