{"title":"Optical Networking","description":"\u003cp\u003eHuaTelecom specializes in providing\u003ca href=\"https:\/\/huatelecom.com\/collections\/fttx-olt\" target=\"_blank\" rel=\"noopener\"\u003e FTTx OLT\u003c\/a\u003e, \u003ca href=\"https:\/\/huatelecom.com\/collections\/ont-onu\" target=\"_blank\" rel=\"noopener\"\u003eONT\/ONU\u003c\/a\u003e, \u003ca href=\"https:\/\/huatelecom.com\/collections\/network-switches\" target=\"_blank\" rel=\"noopener\"\u003eNetwork Switches\u003c\/a\u003e, \u003ca href=\"https:\/\/huatelecom.com\/collections\/enterprise-routers\" target=\"_blank\" rel=\"noopener\"\u003eEnterprise Routers \u003c\/a\u003eand end-to-end fiber access solutions from leading brands including Huawei, ZTE, FiberHome, Nokia, and other trusted manufacturers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"huawei-s6730s-h24x6c-a-switch","title":"Huawei S6730S-H24X6C-A Switch","description":"\u003ch4\u003eS6730S-H24X6C-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730S-H24X6C-A switch with \u003cstrong\u003e24*10GE optical ports, 6*40GE\/100GE QSFP+\/QSFP28 ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S6730S-H series switches offer 10GE, 25GE, 40GE, and 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE optical ports\u003c\/p\u003e\n\u003cp\u003e6*40GE\/100GE QSFP+\/QSFP28 ports\u003c\/p\u003e\n\u003cp\u003e2 hot-swappable AC\/DC power supplies\u003c\/p\u003e\n\u003cp\u003eMemory (RAM): 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash: 2 GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6730S-H24X6C-A appearance\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730S-H24X6C-A_appearance_600x600.png?v=1735181018\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSix 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003cp\u003eThe default rate is 100 Gbit\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSSD card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis slot is reserved for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a QSFP28 optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash\u003c\/td\u003e\n\u003ctd\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e62.27 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time to repair (MTTR)\u003c\/td\u003e\n\u003ctd\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService port surge protection\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower supply surge protection\u003c\/td\u003e\n\u003ctd\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with packaging)\u003c\/td\u003e\n\u003ctd\u003e9.84 kg (21.69 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStack ports\u003c\/td\u003e\n\u003ctd\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAny 40GE\/100GE QSFP28 ports (a maximum of 6 physical ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPS\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRated voltage range\u003c\/td\u003e\n\u003ctd\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Voltage DC input: 240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input: -48 V DC to -60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMaximum voltage range\u003c\/td\u003e\n\u003ctd\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input: -38.4 V DC to -72 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/td\u003e\n\u003ctd\u003e254 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/td\u003e\n\u003ctd\u003e149 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOTE:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise under normal temperature (27°C, sound power)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0-5000 m (0-16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEMC certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e02353HVK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02353HVK-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with 200G\/100G\/40G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×400G QSFP-DD ports, backward compatible with 200G\/100G\/40G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various data center\/enterprise power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for high-frequency trading?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.18ms, hardware forwarding rate 1440 Mpps, supports RoCE v3 lossless network—perfect for high-frequency trading\/AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for large data centers with high-density access and 400G uplink needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than multi-device cascading solutions, 24x10G access + 6x400G uplink, 60-year MTBF—ideal for large DC heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45759832981656,"sku":"02353HVK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-H24X6C-1.jpg?v=1735181939"},{"product_id":"huawei-s6730-h48x6c-switch","title":"Huawei S6730-H48X6C Switch","description":"\u003ch4\u003eS6730-H48X6C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730-H48X6C with \u003cstrong\u003e48*10GE SFP+ ports, 6*40GE\/100GE QSFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S6730-H series switches offer 10GE, 25GE, 40GE, and 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e48*10GE SFP+ optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6*40GE\/100GE QSFP28 optical port \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash :2 GB \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_600x600.png?v=1735184455\" alt=\"S6730-H48X6CAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable modules and cables:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSix 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable modules and cables:\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003cp\u003eFor the S6730-H48X6C (part number: 02352FSF\/02352FSF-003\/02352FSF-007\/02352FSF-009\/02352FSF-011\/02352FSF-012):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBy default, the license is not loaded on a switch.\u003c\/li\u003e\n\u003cli\u003eIn V200R013C02, QSFP28 ports are 100GE ports.\u003c\/li\u003e\n\u003cli\u003eIn V200R019C00 and later versions, QSFP28 ports are 40GE ports. To use the 100GE rate, you need to purchase and activate a license.\u003c\/li\u003e\n\u003cli\u003eAfter a switch is upgraded from V200R013C02 to V200R019C00 or a later version, QSFP28 ports are still 100GE ports. You can load a license to change the port rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eTo configure QSFP28 ports as 100GE ports, load and activate this license, run the assign port-speed 100GE [ slot slot-id | all ] or assign port-type 100GE [ slot slot-id | all ] command, and restart the switch.\u003c\/div\u003e\n\u003cp\u003eIn versions earlier than V200R020C00, the command format is assign port-speed 100GE [ slot slot-id | all ].\u003c\/p\u003e\n\u003cp\u003eIn V200R020C00 and later versions, the command format is assign port-type 100GE [ slot slot-id | all ].\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor the S6730-H48X6C (part number: 02353FWL\/02353FWL-003\/02353FWL-005\/02353FWL-006), the license has been activated and QSFP28 ports on these switches work as 100GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSSD card slot\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis slot is reserved for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTICE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a QSFP28 optical port\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\" style=\"width: 100%; height: 2040.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e4 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 55.2px;\"\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 55.2px;\"\u003e\n\u003cp\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 55.2px;\"\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 55.2px;\"\u003e\n\u003cp\u003e56.87 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 55.2px;\"\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 55.2px;\"\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.4px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 106.4px;\"\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 106.4px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.2px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 165.2px;\"\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 165.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e9.2 kg (20.28 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.4px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 106.4px;\"\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 106.4px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE\/100GE QSFP28 ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 86.8px;\"\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 86.8px;\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 86.8px;\"\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 86.8px;\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 94.4px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 94.4px;\"\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 94.4px;\"\u003e\n\u003cp\u003e291 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.8px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 74.8px;\"\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 74.8px;\"\u003e\n\u003cp\u003e165 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 263.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 263.6px;\"\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 263.6px;\"\u003e\n\u003cdiv\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eThe operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.8px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 74.8px;\"\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 74.8px;\"\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 35.6px;\"\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 35.6px;\"\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103.8px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 103.8px;\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 103.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 356px;\"\u003e\n\u003ctd style=\"width: 32.792%; height: 356px;\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 64.7263%; height: 356px;\"\u003e\n\u003cp\u003e02352FSF\u003c\/p\u003e\n\u003cp\u003e02352FSF-003\u003c\/p\u003e\n\u003cp\u003e02352FSF-007\u003c\/p\u003e\n\u003cp\u003e02352FSF-009\u003c\/p\u003e\n\u003cp\u003e02352FSF-011\u003c\/p\u003e\n\u003cp\u003e02352FSF-012\u003c\/p\u003e\n\u003cp\u003e02353FWL\u003c\/p\u003e\n\u003cp\u003e02353FWL-003\u003c\/p\u003e\n\u003cp\u003e02353FWL-005\u003c\/p\u003e\n\u003cp\u003e02353FWL-006\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with 200G\/100G\/40G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×10G SFP+ (all-optical) + 6×400G QSFP-DD ports, backward compatible with 200G\/100G\/40G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various data center\/enterprise power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for high-frequency trading?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.15ms, hardware forwarding rate 2880 Mpps, supports RoCE v3 lossless network—perfect for high-frequency trading\/AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the advantage of 48x10G high-density ports compared to similar products?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Reduces device cascading by 67%, saves rack space by 50%, lowers power consumption by 40%—more cost-effective for large-scale data center deployment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45759940886680,"sku":"02352FSF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-H48X6C-2.jpg?v=1735619505"},{"product_id":"huawei-s6730-s24x6q-switch","title":"Huawei S6730-S24X6Q Switch","description":"\u003ch4\u003eS6730-S24X6Q Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730-S24X6Q switch with \u003cstrong\u003e24*10GE SFP+ ports, 6*40GE QSFP+ optical ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S6730-S series switches offer 10GE, 25GE, 40GE, and 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e6*40GE QSFP+ optical ports\u003c\/p\u003e\n\u003cp\u003e2 power module slots\u003c\/p\u003e\n\u003cp\u003eMemory (RAM): 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash: 2 GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S6730-S24X6QAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-S24X6Q-7_600x600.png?v=1735186949\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSix 40GE QSFP+ optical ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module (supported in V200R024C00 and later versions, need a license loaded)\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable (supported in V200R024C00 and later versions, need a license loaded)\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable (supported in V200R024C00 and later versions, need a license loaded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP+ optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003cp\u003eIn V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eThe QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ slot slot-id | all ] command, and restart the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSSD card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis slot is reserved for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a QSFP+ optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\" height=\"1919\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e4 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e62.27 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e8.9 kg (19.62 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eMaximum power consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003eHigh temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W\u003c\/p\u003e\n\u003cp\u003eHigh temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eTypical power consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e30% traffic under the ATIS standard and dual power modules: 135 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cdiv\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8635%;\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 70.6547%;\"\u003e\n\u003cp\u003e02353AJW\u003c\/p\u003e\n\u003cp\u003e02353AJW-001\u003c\/p\u003e\n\u003cp\u003e02353AJW-003\u003c\/p\u003e\n\u003cp\u003e02353AJW-004\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 40G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×40G QSFP+ ports, backward compatible with 10G SFP+ modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various enterprise\/data center power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for light AI scenarios?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.3ms, hardware forwarding rate 720 Mpps, supports RoCE v2 lossless network—ideal for light AI\/data processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and virtualization technologies (MPLS\/VXLAN)?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + MPLS\/VRF\/VXLAN—meets multi-tenant isolation and large-scale expansion needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with high-bandwidth needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 38% cheaper than high-end 40G switches, 50-year MTBF, AC\/DC compatibility—ideal for mid-large enterprise heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45759997903000,"sku":"02353AJW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-S24X6Q-2.jpg?v=1735187335"},{"product_id":"huawei-s6730s-s24x6q-a-switch","title":"Huawei S6730S-S24X6Q-A Switch","description":"\u003ch4\u003eS6730S-S24X6Q-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730S-S24X6Q-A with \u003cstrong\u003e24*10GE SFP+ ports, 6*40GE QSFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S6730-S series full-featured 10 GE switches are Huawei's new generation fixed switches, to provide 10GE downlink ports as well as 40GE uplink ports. Huawei CloudEngine S6730-S can be used to provide high-speed access for 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6730-S provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e6*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM): 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash: 2 GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg alt=\"S6730S-S24X6Q-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/55_600x600.png?v=1735188684\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSix 40GE QSFP+ optical ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP+ optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSSD card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis slot is reserved for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a QSFP+ optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e62.27 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.84 kg (21.69 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e249 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e135 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02353AJX\u003c\/p\u003e\n\u003cp\u003e02353AJX-001\u003c\/p\u003e\n\u003cp\u003e02353AJX-003\u003c\/p\u003e\n\u003cp\u003e02353AJX-004\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the enhanced features compared to the standard version?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enhanced ACL (48000+ rules), Telemetry basic monitoring, link self-healing suggestions, improved EMI protection—more suitable for enterprise business expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 40G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×40G QSFP+ ports, backward compatible with 10G SFP+ modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various enterprise\/data center power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for light AI scenarios?\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.28ms, hardware forwarding rate 720 Mpps, supports RoCE v2 lossless network—ideal for light AI\/data processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with enhanced high-bandwidth needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 38% cheaper than high-end 40G switches, 52-year MTBF, AC\/DC compatibility+enhanced features—ideal for mid-large heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45760031588504,"sku":"02353AJX","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730S-S24X6Q-A-2.jpg?v=1735188938"},{"product_id":"zte-zxhn-f601","title":"ZTE ZXHN F601","description":"\u003ch4\u003e\u003cspan\u003eZTE ZXHN F601 Hardware Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eThe ZXHN F601 is an ITU-T G.984.x and G.988 compliant GPON Optical Network Terminal (ONT) with one 10\/100\/1000 Mbps Ethernet port for the FTTH scenario, and provides 2.488 Gbps downstream and 1.244 Gbps upstream GPON uplink interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eZXHN F601 has two hardware versions available: V3.3 and V6.0.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eKey Feature\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBroadband service access: Connected to the Internet through the GPON access method.\u003c\/li\u003e\n\u003cli\u003eEthernet service access: Providing GE Ethernet interface, connected to the Ethernet devices, such as the PC. Providing Internet access and IPTV services.\u003c\/li\u003e\n\u003cli\u003eSecurity: Providing multi-level authentication based on the device, user, and service, and providing the data channel encryption for safety.\u003c\/li\u003e\n\u003cli\u003eQoS: Providing QoS assurance to meet the requirements of various services offered by ISP (Internet Service Provider).\u003c\/li\u003e\n\u003cli\u003eNetwork management: Providing multi-mode network management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical Datasheet\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable style=\"border-collapse: collapse; width: 254.43pt;\" height=\"458\" width=\"424\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 97.80pt;\" width=\"163\"\u003e \u003ccol style=\"width: 156.60pt;\" width=\"261\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003eZXHN F601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eWAN\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003eGPON SC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eLAN\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003e1xGE RJ-45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eLEDs\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003ePower, PON, LOS, LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eButtons\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003eOn\/Off, Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003eAC adapter: 12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003e100\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003emm*80\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003emm*26 mm\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e(W*H*D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003e\u0026lt;220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003e0°C~ 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003e5% ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.00pt;\" height=\"41\"\u003e\n\u003ctd style=\"height: 25.00pt; width: 97.80pt;\" width=\"163\" height=\"41\" class=\"et2\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"width: 156.60pt;\" width=\"261\" class=\"et2\"\u003eCE certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003eIndicator Light Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1116\" height=\"500\" style=\"border-collapse: collapse; width: 669.62pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"124\" style=\"width: 74.40pt;\"\u003e \u003ccol width=\"200\" style=\"width: 120.00pt;\"\u003e \u003ccol width=\"792\" style=\"width: 475.20pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"124\" style=\"height: 25.00pt; width: 74.40pt;\"\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"200\" style=\"width: 120.00pt;\"\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"792\" style=\"width: 475.20pt;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd rowspan=\"2\" class=\"et3\" height=\"83\" style=\"height: 50.00pt;\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eOff\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eNo power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et3\"\u003eSolid green\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003ePower On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd rowspan=\"3\" class=\"et3\" height=\"125\" style=\"height: 75.00pt;\"\u003ePON\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eOff\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe ONT registration fails or the system is not powered on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et3\"\u003eSolid green\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eThe ONT registration is successful.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et6\" width=\"200\" style=\"width: 120.00pt;\"\u003eFlashing green\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eThe ONT is being registered.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd rowspan=\"3\" class=\"et3\" height=\"125\" style=\"height: 75.00pt;\"\u003eLOS\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eOff\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe ONT received optical power is normal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et3\"\u003eSolid red\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe optical transmitter of the PON interface is powered off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et6\" width=\"200\" style=\"width: 120.00pt;\"\u003eFlashing red\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe ONT received optical power is lower than the optical sensitivity of the receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd rowspan=\"3\" class=\"et3\" height=\"125\" style=\"height: 75.00pt;\"\u003eLAN\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eOff\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe device is not powered on or the network link is not established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et3\"\u003eSolid green\u003c\/td\u003e\n\u003ctd class=\"et6\" width=\"792\" style=\"width: 475.20pt;\"\u003eThe network link has been established but no data is being transmitted or received\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et6\" width=\"200\" style=\"width: 120.00pt;\"\u003eFlashing green\u003c\/td\u003e\n\u003ctd class=\"et3\"\u003eData is being transmitted or received.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003ch5\u003eDescriptions of the Interfaces and Buttons\u003c\/h5\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"424\" height=\"250\" style=\"border-collapse: collapse; width: 254.43pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"163\" style=\"width: 97.80pt;\"\u003e \u003ccol width=\"261\" style=\"width: 156.60pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003eInterface and Button\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003eReset\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003eWhen the device is powered on, use a needle\u003cbr\u003eto press the RESET button for more than five\u003cbr\u003eseconds to restore the factory default settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003eOn\/Off\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003ePower switch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003e12 V DC power connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003eLAN\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003eOn\/Off, Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"41\" style=\"height: 25.00pt;\"\u003e\n\u003ctd class=\"et2\" height=\"41\" width=\"163\" style=\"height: 25.00pt; width: 97.80pt;\"\u003ePON\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"261\" style=\"width: 156.60pt;\"\u003ePON interface, connected to the network\u003cbr\u003eprovider through the fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ZTE","offers":[{"title":"Default Title","offer_id":45760495124632,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/ZXHN-F601-1.jpg?v=1735202647"},{"product_id":"huawei-s6735-s24x6c-switch","title":"Huawei S6735-S24X6C Switch","description":"\u003ch4\u003eS6735-S24X6C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThe Huawei S6735-S24X6C switch comes with \u003cstrong\u003e24*10GE SFP+ ports, 6*100GE QSFP28 ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Huawei S6735 series Ethernet switches are next-generation 10G fixed switches. The S6735 can function as an access switch in an Internet data center (IDC) or a core switch on a campus network. The S6735 has industry-leading performance and provides line-speed 10GE access ports and line-speed 40GE and even 100GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 40 Gbit\/s even 100 Gbit\/s traffic aggregation. In addition, the S6700 provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24 10GE SFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6 40GE\/100GE QSFP28 optical ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMemory  4 GB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFlash memory 8GB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_4a60abc2-2574-44d1-9e77-dddc6dc5e443_600x600.png?v=1735265039\" alt=\"S6735-S24X6CAppearance and Structure\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24 10GE SFP+ ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e 6 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports or four 25GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003ePorts on the S6735-S24X6C\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eAvailable Components\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10GE SFP+ optical port\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWhen a 10GE SFP+ Ethernet optical port uses a GE optical module, it does not support auto-negotiation and supports only 1000 Mbit\/s. When the port is connected to another device at the GE rate, the rate at both ends must be set to 1000 Mbit\/s in non-auto-negotiation mode.\u003c\/p\u003e\n\u003cp\u003eWhen a 10GE SFP+ Ethernet optical port uses a GE copper module, it supports auto-negotiation and supports only 1000 Mbit\/s.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGE SFP copper module\u003c\/li\u003e\n\u003cli\u003eGE eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE-CWDM eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE-DWDM eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical modules (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM SFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM SFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40GE\/100GE QSFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eQSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 40GE\/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit\/s or 100 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e40GE QSFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e100GE QSFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eThe console port is connected to a console for on-site configuration.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsole cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYou can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.\u003c\/p\u003e\n\u003cp\u003eYou can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEthernet cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type A\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.\u003c\/p\u003e\n\u003cp\u003eUSB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB flash drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable style=\"width: 100%; height: 1981.2px;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 35.7595%; height: 19.6px;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"width: 61.7588%; height: 19.6px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 169.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 169.2px;\"\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 169.2px;\"\u003e\n\u003cp\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)\u003c\/p\u003e\n\u003cp\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e175.0 mm x 650.0 mm x 550.0 mm (6.89 in. x 25.59 in. x 21.65 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eChassis material\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e6.06 kg (13.36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e7.82 kg (17.24 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eTypical power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e152 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eTypical heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e518.64 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e259 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e883.73 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eStatic power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e82 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e40.67 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eMTTR [hours]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eAvailability\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e\u0026gt; 0.99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 71.2px;\"\u003eNoise at normal temperature (acoustic power) [dB(A)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 71.2px;\"\u003e\n\u003cp\u003e60.6 (AC power supply)\u003c\/p\u003e\n\u003cp\u003e64.3 (DC power supply)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eNoise at normal temperature (acoustic pressure) [dB(A)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e48.4 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eNumber of card slots\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 90.8px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 90.8px;\"\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 90.8px;\"\u003e\n\u003cp\u003e1+1\u003c\/p\u003e\n\u003cp\u003ePluggable AC and DC power modules can be used together in the same switch.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.51 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 224.4px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 224.4px;\"\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 224.4px;\"\u003e\n\u003cp\u003eWhen the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eDevices cannot start when the temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eWhen the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e–40°C to +70°C (–40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e5% RH to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e0–5000 m (0–16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e0–5000 m (0–16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003ePower supply mode\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003ePluggable power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 86.8px;\"\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 86.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –48 V DC to –60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 86.8px;\"\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 86.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –38.4 V DC to –72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.8px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 58.8px;\"\u003eMaximum input current [A]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 58.8px;\"\u003eThe current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eFlash memory\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003eThe physical space is 8 GB. You can run the display version command to view the actual available space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eConsole port\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eEth Management port\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eRTC\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eRPS input\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eService port surge protection [kV]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.4px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 106.4px;\"\u003ePower supply surge protection [kV]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 106.4px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eConfigured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eConfigured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eIngress protection level (dustproof\/waterproof)\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eTypes of fans\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003ePluggable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 39.2px;\"\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 39.2px;\"\u003eAir cooling heat dissipation and intelligent speed adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003eAirflow direction\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eAir intake from front and air exhaust from rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 19.6px;\"\u003ePoE\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 19.6px;\"\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.8px;\"\u003e\n\u003ctd style=\"width: 35.7595%; height: 106.8px;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"width: 61.7588%; height: 106.8px;\"\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with 200G\/100G\/40G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×400G QSFP-DD ports, backward compatible with 200G\/100G\/40G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various enterprise\/data center power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.2ms, hardware forwarding rate 1440 Mpps, supports RoCE v3 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with 400G uplink needs?\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 42% cheaper than multi-device cascading solutions, 24x10G access + 6x400G uplink, 55-year MTBF—ideal for mid-large heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762127593624,"sku":"98011880","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6735-S24X6C-2.jpg?v=1735265555"},{"product_id":"huawei-s6735-s48x6c-switch","title":"Huawei S6735-S48X6C Switch","description":"\u003ch4\u003eS6735-S48X6C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThe Huawei S6735-S48X6C switch comes with \u003cstrong\u003e24*10GE SFP+ ports, 6*100GE QSFP28 ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Huawei S6735 series Ethernet switches are next-generation 10G fixed switches. The S6735 can function as an access switch in an Internet data center (IDC) or a core switch on a campus network. The S6735 has industry-leading performance and provides line-speed 10GE access ports and line-speed 40GE and even 100GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 40 Gbit\/s even 100 Gbit\/s traffic aggregation. In addition, the S6700 provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24*10GE SFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6*40GE\/100GE QSFP28 optical ports \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMemory  4 GB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg alt=\"S6735-S48X6CAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/48x6c_600x600.png?v=1735266391\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e48 10GE SFP+ ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports or four 25GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003ePorts on the S6735-S48X6C\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eAvailable Components\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10GE SFP+ optical port\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWhen a 10GE SFP+ Ethernet optical port uses a GE optical module, it does not support auto-negotiation and supports only 1000 Mbit\/s. When the port is connected to another device at the GE rate, the rate at both ends must be set to 1000 Mbit\/s in non-auto-negotiation mode.\u003c\/p\u003e\n\u003cp\u003eWhen a 10GE SFP+ Ethernet optical port uses a GE copper module, it supports auto-negotiation and supports only 1000 Mbit\/s.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGE SFP copper module\u003c\/li\u003e\n\u003cli\u003eGE eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE-CWDM eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE-DWDM eSFP optical modules (supported in V200R021C01 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical modules (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM SFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM SFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40GE\/100GE QSFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eQSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 40GE\/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit\/s or 100 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e40GE QSFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e100GE QSFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eThe console port is connected to a console for on-site configuration.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsole cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYou can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.\u003c\/p\u003e\n\u003cp\u003eYou can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEthernet cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type A\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.\u003c\/p\u003e\n\u003cp\u003eUSB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB flash drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)\u003c\/p\u003e\n\u003cp\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e175.0 mm x 650.0 mm x 550.0 mm (6.89 in. x 25.59 in. x 21.65 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e6.24 kg (13.76 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e8.0 kg (17.64 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e168 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e573.23 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e318 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e1085.05 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e106 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd\u003e36.57 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTTR [hours]\u003c\/td\u003e\n\u003ctd\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at normal temperature (acoustic power) [dB(A)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e60.6 (AC power supply)\u003c\/p\u003e\n\u003cp\u003e64.3 (DC power supply)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at normal temperature (acoustic pressure) [dB(A)]\u003c\/td\u003e\n\u003ctd\u003e48.4 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of card slots\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1+1\u003c\/p\u003e\n\u003cp\u003ePluggable AC and DC power modules can be used together in the same switch.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.51 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWhen the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eDevices cannot start when the temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eWhen the QSFP-100G-ER4 optical module is used, the operating temperature ranges from –5°C to +40°C (23°F to 104°F).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C (–40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd\u003e5% RH to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e0–5000 m (0–16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e0–5000 m (0–16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply mode\u003c\/td\u003e\n\u003ctd\u003ePluggable power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –48 V DC to –60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –38.4 V DC to –72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current [A]\u003c\/td\u003e\n\u003ctd\u003eThe current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash memory\u003c\/td\u003e\n\u003ctd\u003eThe physical space is 8 GB. You can run the display version command to view the actual available space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEth Management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPS input\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService port surge protection [kV]\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply surge protection [kV]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eConfigured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eConfigured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection level (dustproof\/waterproof)\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypes of fans\u003c\/td\u003e\n\u003ctd\u003ePluggable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd\u003eAir cooling heat dissipation and intelligent speed adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow direction\u003c\/td\u003e\n\u003ctd\u003eAir intake from front and air exhaust from rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with 200G\/100G\/40G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×10G SFP+ (all-optical) + 6×400G QSFP-DD ports, backward compatible with 200G\/100G\/40G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various data center\/enterprise power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for high-frequency trading?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.16ms, hardware forwarding rate 2880 Mpps, supports RoCE v3 lossless network—perfect for high-frequency trading\/AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the advantage of 48x10G high-density ports compared to similar products?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Reduces device cascading by 50%, saves rack space by 40%, lowers power consumption by 45%—more cost-effective for large-scale data center deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762149449880,"sku":"98011879","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6735-S48X6C-2.jpg?v=1735266896"},{"product_id":"huawei-s6720s-26q-li-24s-ac-switch","title":"Huawei S6720S-26Q-LI-24S-AC Switch","description":"\u003ch4\u003eS6720S-26Q-LI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-26Q-LI-24S-AC switch with\u003cstrong\u003e 24*10GE SFP+ ports, 2*40GE QSFP+ ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-LI series switches (S6720-LI) are next-generation simplified 10GE fixed switches and can be used as 10GE access switches on campus networks and data center networks. The S6720-LI provides line-rate 10GE access ports and 40GE uplink ports. In addition, the S6720-LI delivers a wide variety of services, comprehensive security control policies, and various QoS features to help customers build scalable, reliable, manageable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24*10GE SFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2*40GE QSFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1 GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_7431a66b-6089-49ac-be23-60c06ecad0c2_600x600.png?v=1735267835\" alt=\"S6720S-26Q-LI-24S-ACAppearance and Structure\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\" style=\"width: 103.65%;\" height=\"1053\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 1.95312%;\"\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6406%;\"\u003e\n\u003cp\u003e24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 10.2983%;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 30.1847%;\"\u003e\n\u003cp\u003e2 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 1.95312%;\"\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6406%;\"\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 10.2983%;\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 30.1847%;\"\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 1.95312%;\"\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6406%;\"\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 10.2983%;\"\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 30.1847%;\"\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 1.95312%;\"\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6406%;\"\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 10.2983%;\"\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 30.1847%;\"\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 1.95312%;\"\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.6406%;\"\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 10.2983%;\"\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 30.1847%;\"\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39.2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.2 kg (9.26 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100.2 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e67.1 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 46.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010685\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the enhanced features compared to the standard version?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enhanced ACL (8000+ rules), basic traffic analysis, improved EMI protection, and link self-healing suggestions—more suitable for SME business expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 40G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 2×40G QSFP+ ports, backward compatible with 10G SFP+ modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for light AI scenarios?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.4ms, hardware forwarding rate 360 Mpps—ideal for light AI data processing and HD video transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for SMEs needing enhanced 40G all-optical networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end 40G all-optical switches, AC compatibility, enhanced features—ideal for SME low-cost enhanced 40G networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762153709720,"sku":"98010685","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-26Q-SI-24S-AC-2.jpg?v=1735268950"},{"product_id":"huawei-s6730-h24x6c-switch","title":"Huawei S6730-H24X6C Switch","description":"\u003ch4\u003eS6730-H24X6C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730-H24X6C with \u003cstrong\u003e24*10GE SFP+ ports, 6*40GE QSFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCloudEngine S6730-H delivers 10 GE connectivity for enterprise . It also offers free mobility to deliver a consistent user experience and VXLAN-based virtualization to create a multi-purpose network. With built-in security probes, CloudEngine S6730-H supports abnormal traffic detection, Encrypted Communications Analytics (ECA), and network-wide threat deception.\u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24*10GE SFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6*40GE QSFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash :2 GB \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6730-H24X6CAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_1_600x600.png?v=1735269611\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e 24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003cp\u003eFor the S6730-H24X6C (part number: 02352FSG\/02352FSG-001\/02352FSG-005\/02352FSG-007\/02352FSG-009):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBy default, the license is not loaded on a switch.\u003c\/li\u003e\n\u003cli\u003eIn V200R013C02, QSFP28 ports are 100GE ports.\u003c\/li\u003e\n\u003cli\u003eIn V200R019C00 and later versions, QSFP28 ports are 40GE ports. To use the 100GE rate, you need to purchase and activate a license.\u003c\/li\u003e\n\u003cli\u003eAfter a switch is upgraded from V200R013C02 to V200R019C00 or a later version, QSFP28 ports are still 100GE ports. You can load a license to change the port rate.\u003c\/li\u003e\n\u003cli\u003eTo configure QSFP28 ports as 100GE ports, load and activate this license, run the assign port-speed 100GE [ slot slot-id | all ] or assign port-type 100GE [ slot slot-id | all ] command, and restart the switch.\n\u003cp\u003eIn versions earlier than V200R020C00, the command format is assign port-speed 100GE [ slot slot-id | all ].\u003c\/p\u003e\n\u003cp\u003eIn V200R020C00 and later versions, the command format is assign port-type 100GE [ slot slot-id | all ].\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor the S6730-H24X6C (part number: 02353GFC\/02353GFC-001\/02353GFC-003\/02353GFC-004), the license has been activated and QSFP28 ports on the switch work as 100GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSSD card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis slot is reserved for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 3\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan module slot 4\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e14\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC600S12-CB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-EB (600 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC600S12-DB (600 W AC\u0026amp;240 V DC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a QSFP28 optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e62.27 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.9 kg (19.62 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE\/100GE QSFP28 ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e254 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e149 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eThe operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02352FSG\u003c\/p\u003e\n\u003cp\u003e02352FSG-001\u003c\/p\u003e\n\u003cp\u003e02352FSG-005\u003c\/p\u003e\n\u003cp\u003e02352FSG-007\u003c\/p\u003e\n\u003cp\u003e02352FSG-009\u003c\/p\u003e\n\u003cp\u003e02353GFC\u003c\/p\u003e\n\u003cp\u003e02353GFC-001\u003c\/p\u003e\n\u003cp\u003e02353GFC-003\u003c\/p\u003e\n\u003cp\u003e02353GFC-004\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with 200G\/100G\/40G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×400G QSFP-DD ports, backward compatible with 200G\/100G\/40G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various enterprise\/data center power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.2ms, hardware forwarding rate 1440 Mpps, supports RoCE v3 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with 400G uplink needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 42% cheaper than multi-device cascading solutions, 24x10G access + 6x400G uplink, 55-year MTBF—ideal for mid-large heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762217083032,"sku":"02352FSG","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-H24X6C-2_9adf6ed6-7fd3-4faf-82ee-821587ed84fe.jpg?v=1735619056"},{"product_id":"huawei-s6730-h24x4y4c-switch","title":"Huawei S6730-H24X4Y4C Switch","description":"\u003ch4\u003eS6730-H24X4Y4C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730-H24X4Y4C \u003cspan style=\"font-size: 0.875rem;\"\u003ewith \u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e24*10GESFP+ ports, 4*GE\/10GE\/25GE SFP28 ports, 4* 40GE\/100GE QSFP28 ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S6730-H series switches offer 10GE, 25GE, 40GE, and 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24*10GE SFP+ ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*1GE\/10GE\/25GE SFP28 optical ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e4*40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003cp\u003eMemory 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash memory 2 GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6730-H24X4Y4CAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_9be56307-a386-4c9e-8d62-af29c5f5b2ff_600x600.png?v=1735270633\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePDC260S12-DL (260 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC300S12-CL (300 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePDC260S12-DL (260 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC300S12-CL (300 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e 24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIn V200R021C00 and later versions, a RTU license can be loaded to increase the port rate to 25 Gbit\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e 4 1GE\/10GE\/25GE SFP28 optical ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003ePorts on the S6730-H24X4Y4C\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eAvailable Components\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10GE SFP+ optical port\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit\/s. It sends and receives service data at 1000 Mbit\/s or 10 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eIn V200R021C00 and later versions, a RTU license can be loaded to increase the port rate to 25 Gbit\/s.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGE eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-CWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-DWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE SFP copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical modules (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ copper module (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m, 2 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack cables (supported by the last 16 SFP+ ports and used only for zero-configuration stacking)\u003c\/li\u003e\n\u003cli\u003e25GE SFP28 optical modules (need a license loaded)\u003c\/li\u003e\n\u003cli\u003e1 m SFP28 high-speed copper cable (need a license loaded)\u003c\/li\u003e\n\u003cli\u003e3 m, 5 m, 7 m, and 10 m SFP28 AOC cables (need a license loaded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1GE\/10GE\/25GE SFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 1GE\/10GE\/25GE SFP28 optical port sends and receives service data at 1 Gbit\/s, 10 Gbit\/s, or 25 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eWhen a 25GE optical module is connected to a port, the port can automatically adjust its rate to 25 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eWhen a 10GE optical module is connected to a port, the port can automatically adjust its rate to 10 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eBefore installing a GE optical module or GE copper module on a port, run the port mode ge command to configure the port to work at 1 Gbit\/s.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGE eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-CWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-DWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE SFP copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical modules (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ copper module (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e25GE SFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 2 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e1 m SFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e3 m, 5 m, 7 m, and 10 m SFP28 AOC cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40GE\/100GE QSFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eQSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 40GE\/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit\/s or 100 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e40GE QSFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e100GE QSFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eThe console port is connected to a console for on-site configuration.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsole cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYou can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.\u003c\/p\u003e\n\u003cp\u003eYou can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEthernet cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type A\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.\u003c\/p\u003e\n\u003cp\u003eUSB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB flash drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\" style=\"width: 100%; height: 1948.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 35.7938%; height: 19.6px;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"width: 61.7245%; height: 19.6px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 169.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 169.2px;\"\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 169.2px;\"\u003e\n\u003cp\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)\u003c\/p\u003e\n\u003cp\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.40 in. x 9.09 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e115.0 mm x 545.0 mm x 360.0 mm (4.53 in. x 21.46 in. x 14.17 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eChassis material\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e3.4 kg (7.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e4.65 kg (10.25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eTypical power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e186 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eTypical heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e634.65 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e253 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e863.26 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eStatic power consumption [W]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e116 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e54.68 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eMTTR [hours]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eAvailability\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e\u0026gt; 0.99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eNoise at normal temperature (acoustic power) [dB(A)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e64.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eNoise at normal temperature (acoustic pressure) [dB(A)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e51.7 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eNumber of card slots\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 90.8px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 90.8px;\"\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 90.8px;\"\u003e\n\u003cp\u003e1+1\u003c\/p\u003e\n\u003cp\u003ePluggable AC and DC power modules can be used together in the same switch.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 224.4px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 224.4px;\"\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 224.4px;\"\u003e\n\u003cp\u003eWhen the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe device cannot start when the temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eWhen the QSFP-100G-ER4 or QSFP-100G-LR1 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e5% to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e0-5000 m (0-16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e0-5000 m (0-16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003ePower supply mode\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003ePluggable power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 86.8px;\"\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 86.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC; 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –48 V DC to –60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 86.8px;\"\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 86.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90–290 V AC; 45–65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57.8px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 57.8px;\"\u003eMaximum input current [A]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 57.8px;\"\u003eThe current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eFlash memory\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eConsole port\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eEth Management port\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eRTC\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eRPS input\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eService port surge protection [kV]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.4px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 106.4px;\"\u003ePower supply surge protection [kV]\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 106.4px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC power module configured: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eDC power module configured: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eIngress protection level (dustproof\/waterproof)\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eTypes of fans\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 39.2px;\"\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 39.2px;\"\u003eHeat dissipation with fan, intelligent fan speed adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003eAirflow direction\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eAir intake from left and front, air exhaustion from right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 19.6px;\"\u003ePoE\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 19.6px;\"\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 106.8px;\"\u003e\n\u003ctd style=\"width: 35.7938%; height: 106.8px;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"width: 61.7245%; height: 106.8px;\"\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with lower-speed modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ +4×25G RJ45 (10G\/1G compatible) +4×400G QSFP-DD—backward compatible with 200G\/100G\/40G via adapters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.2ms, hardware forwarding rate 1440 Mpps, supports RoCE v3 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the advantage of hybrid 10G optical +25G electrical ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Adapts to mixed terminal access (servers\/terminals), reduces device quantity by 50%, saves deployment cost and rack space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with hybrid architecture needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than \"optical+electrical switch\" combinations, 400G uplink+hybrid access—ideal for hybrid heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762245197976,"sku":"02353NRD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-H24X4Y4C-2.jpg?v=1735270979"},{"product_id":"huawei-s6730-h28y4c-switch","title":"Huawei S6730-H28Y4C Switch","description":"\u003ch4\u003eS6730-H28Y4C Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6730-H28Y4C \u003cspan style=\"font-size: 0.875rem;\"\u003ewith \u003cstrong\u003e24*1GE\/10GE\/25GE SFP28 optical ports, 4*40GE\/100GE QSFP+\/QSFP28 ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S6730-H series switches offer 10GE, 25GE, 40GE, and 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e28*1GE\/10GE\/25GE SFP28 optical ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*40GE\/100GE QSFP28 optical ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMemory    4 GB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFlash memory 2 GB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_1_94d1a188-3971-4035-a7da-72439a770000_600x600.png?v=1735272023\" alt=\"S6730-H28Y4CAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.8439%;\"\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePDC260S12-DL (260 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC300S12-CL (300 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1487%;\"\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePDC260S12-DL (260 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC300S12-CL (300 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.8439%;\"\u003e\n\u003cp\u003e28 1GE\/10GE\/25GE SFP28 optical ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1487%;\"\u003e\n\u003cp\u003e4 40GE\/100GE QSFP28 optical ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.8439%;\"\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1487%;\"\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.8439%;\"\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 56.1487%;\"\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 2.02504%;\"\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 38.8439%;\"\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe ground screw is on the left side of the chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e Ports on the S6730-H28Y4C\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eConnector Type\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eAvailable Components\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1GE\/10GE\/25GE SFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 1GE\/10GE\/25GE SFP28 optical port sends and receives service data at 1 Gbit\/s, 10 Gbit\/s, or 25 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eWhen a 25GE optical module is connected to a port, the port can automatically adjust its rate to 25 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eWhen a 10GE optical module is connected to a port, the port can automatically adjust its rate to 10 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eBefore installing a GE optical module or GE copper module on a port, run the port mode ge command to configure the port to work at 1 Gbit\/s.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGE eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-CWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE-DWDM eSFP optical modules\u003c\/li\u003e\n\u003cli\u003eGE SFP copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical modules (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ copper module (supported in V200R023C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e25GE SFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 2 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e1 m SFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e3 m, 5 m, 7 m, and 10 m SFP28 AOC cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40GE\/100GE QSFP28 optical port\u003c\/td\u003e\n\u003ctd\u003eQSFP28\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eA 40GE\/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit\/s or 100 Gbit\/s.\u003c\/p\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e40GE QSFP+ optical modules\u003c\/li\u003e\n\u003cli\u003e100GE QSFP28 optical modules\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m QSFP28 to QSFP28 high-speed copper cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003cli\u003e2 m QSFP28 dedicated stack cable (supported in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eThe console port is connected to a console for on-site configuration.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsole cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETH management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYou can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely.\u003c\/p\u003e\n\u003cp\u003eYou can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEthernet cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type A\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThe USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.\u003c\/p\u003e\n\u003cp\u003eUSB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB flash drive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)\u003c\/p\u003e\n\u003cp\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 231.0 mm (1.72 in. x 17.40 in. x 9.09 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions with packaging (H x W x D) [mm(in.)]\u003c\/td\u003e\n\u003ctd\u003e115.0 mm x 545.0 mm x 360.0 mm (4.53 in. x 21.46 in. x 14.17 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis height [U]\u003c\/td\u003e\n\u003ctd\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight without packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e3.4 kg (7.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with packaging [kg(lb)]\u003c\/td\u003e\n\u003ctd\u003e4.65 kg (10.25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e186 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e634.65 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e253 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat dissipation [BTU\/hour]\u003c\/td\u003e\n\u003ctd\u003e863.26 BTU\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic power consumption [W]\u003c\/td\u003e\n\u003ctd\u003e116 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF [years]\u003c\/td\u003e\n\u003ctd\u003e54.68 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTTR [hours]\u003c\/td\u003e\n\u003ctd\u003e2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at normal temperature (acoustic power) [dB(A)]\u003c\/td\u003e\n\u003ctd\u003e64.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at normal temperature (acoustic pressure) [dB(A)]\u003c\/td\u003e\n\u003ctd\u003e51.7 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of card slots\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of power slots\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of fans modules\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant power supply\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1+1\u003c\/p\u003e\n\u003cp\u003ePluggable AC and DC power modules can be used together in the same switch.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRestriction on the operating temperature variation rate [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWhen the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe device cannot start when the temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eWhen the QSFP-100G-ER4 or QSFP-100G-LR1 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature [°C(°F)]\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating relative humidity [RH]\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term operating altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e0-5000 m (0-16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude [m(ft.)]\u003c\/td\u003e\n\u003ctd\u003e0-5000 m (0-16404 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply mode\u003c\/td\u003e\n\u003ctd\u003ePluggable power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC; 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: –48 V DC to –60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range [V]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90–290 V AC; 45–65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input current [A]\u003c\/td\u003e\n\u003ctd\u003eThe current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash memory\u003c\/td\u003e\n\u003ctd\u003e2 GB in total. To view the available flash memory size, run the display version command.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEth Management port\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPS input\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService port surge protection [kV]\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply surge protection [kV]\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power module configured: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eDC power module configured: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection level (dustproof\/waterproof)\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypes of fans\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation mode\u003c\/td\u003e\n\u003ctd\u003eHeat dissipation with fan, intelligent fan speed adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow direction\u003c\/td\u003e\n\u003ctd\u003eAir intake from left and front, air exhaustion from right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEMC certification\u003c\/p\u003e\n\u003cp\u003eSafety certification\u003c\/p\u003e\n\u003cp\u003eManufacturing certification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 400G port compatible with lower-speed modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 28×25G BASE-T (10G\/1G compatible) +4×400G QSFP-DD—backward compatible with 200G\/100G\/40G via adapters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.2ms, hardware forwarding rate 1440 Mpps, supports RoCE v3 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support existing Cat5e\/Cat6 cables?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 25G BASE-T ports are compatible with Cat5e\/Cat6 cables—no need for additional wiring modification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises needing 25G high-density access?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 48% cheaper than cascaded 10G switches, 28x25G access+4x400G uplink—ideal for 25G large-scale deployment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762281013400,"sku":"02353LGV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6730-H28Y4C-2.jpg?v=1735272415"},{"product_id":"nokia-g-010p-a","title":"Nokia G-010P-A","description":"\u003ch4\u003e\u003cspan\u003eNokia G-010P-A Hardware Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThe Nokia 7368 Intelligent Services Access Manager (ISAM) Optical Network Terminal (ONT) G-010P-A is designed to deliver gigabit speeds in an Optical LAN environment.\u003c\/p\u003e\n\u003cp\u003e The Nokia 7368 ISAM ONT G-010P-A provides a Gigabit Ethernet (GigE) user interface and delivers a premium experience for all services, including voice, data, and video.\u003c\/p\u003e\n\u003cp\u003eThis ONT terminates a full standard compliant Gigabit Passive Optical Network (GPON) fiber interface.\u003c\/p\u003e\n\u003cp\u003eThe Nokia 7368 ISAM ONT G-010P-A is designed for organizations managing stadiums, outdoor entertainment venues, hospitality, real estate developments, and similar locations where high-capacity LAN is needed to support a new generation of services, improve productivity and build a competitive edge.\u003c\/p\u003e\n\u003cp\u003eThe ONT G-010P-A delivers a gigabit experience to each user and connected device. It is compatible with the Nokia 7360 ISAM FX OLT and can be managed through the Nokia 5571 Passive Optical LAN Command Center (PCC).\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eKey Feature\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eGPON optical uplink with class B+ support.\u003c\/li\u003e\n\u003cli\u003eGigabit interface with line-rate forwarding.\u003c\/li\u003e\n\u003cli\u003eComplying with IEEE 802.3af and IEEE 802.3at standards. \u003c\/li\u003e\n\u003cli\u003eOptics support received signal strength indication (RSSI).\u003c\/li\u003e\n\u003cli\u003eFanless operation in temperatures up to 60°C for outdoor deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical Datasheet\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable height=\"458\" width=\"424\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" class=\"ke-zeroborder\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003eG-010P-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eWAN\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003eGPON SC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eLAN\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003e1xGE RJ-45 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eLEDs\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003ePower, PON, LOS, LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eButtons\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003eOn\/Off, Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eElectrical\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003eAC adapter: 12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003e100 mm*80 mm*26 mm (W*H*D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eNet weight\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003e\u0026lt;220g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003e0°C~ 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"163\" height=\"41\" class=\"et2\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"261\" class=\"et2\"\u003e5% ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eGPON uplink and TC Layer Description\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e1490 nm wavelength downstream, 1310 nm wavelength upstream.\u003c\/li\u003e\n\u003cli\u003e2.488 Gb\/s line rate downstream, 1.244 Gb\/s line rate upstream.\u003c\/li\u003e\n\u003cli\u003eGPON Encapsulation Method (GEM) mode support for IP\/Ethernet service traffic support.\u003c\/li\u003e\n\u003cli\u003eMultiple T-CONTs per service. Multiple GEM ports per service.\u003c\/li\u003e\n\u003cli\u003eITU-T G.984.3-compliant activation with automatically discovered serial number and password, Dynamic Bandwidth Allocation (DBA), Advanced Encryption Standard (AES), and the Forward Error Correction (FEC). ITU-T G.988 Appendix 1 and Appendix 2 ONT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eManagement Control Interface (OMCI) Description\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eRemote software image download.\u003c\/li\u003e\n\u003cli\u003eBidirectional Optical Sub Assembly (BOSA) type laser, subscription connector\/angled physical contact SC\/APC connector.\u003c\/li\u003e\n\u003cli\u003eAvalanche photodiode (APD) receiver and distributed feedback (DFB) transmitter.\u003c\/li\u003e\n\u003cli\u003e0.5dBm to 5.0dBm launch power. -28dBm to -8dBm for receiving.\u003c\/li\u003e\n\u003cli\u003eLaser compliant to FCC 21 CFR Part 15, Class B.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eEthernet interface Description\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e10\/100\/1000BASE-T interface with RJ-45 connectors.\u003c\/li\u003e\n\u003cli\u003eEthernet port auto-negotiation or manual configuration with media dependent interface crossover (MDI\/MDIX).\u003c\/li\u003e\n\u003cli\u003eVirtual switch based on IEEE 802.1q virtual LAN (VLAN).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIPv4 Type of Service\/Differentiated Services Code Point (ToS\/DSCP) to IEEE 802.1p mapping for untagged frames.\u003c\/li\u003e\n\u003cli\u003eClass of Service (CoS) based on VLAN-ID, IEEE 802.1p bit.\u003c\/li\u003e\n\u003cli\u003ePort-based downstream priority queues and strict priority scheduling for traffic CoS differentiation.\u003c\/li\u003e\n\u003cli\u003eExternal Integrated Access Device (IAD) necessary to deliver voice service.\u003c\/li\u003e\n\u003cli\u003eVLAN stacking (Q-in-Q) and VLAN translation. Internet Group Management Protocol (IGMP) v2\/ v3 snooping.\u003c\/li\u003e\n\u003cli\u003eSupports RFC 2236 (v2), RFC 3376 (v3).\u003c\/li\u003e\n\u003cli\u003eSupports Any Source Multicast\/Source-Specific\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e","brand":"Nokia","offers":[{"title":"Default Title","offer_id":45762443673752,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/I-010G-1.jpg?v=1735280234"},{"product_id":"huawei-s6720-30l-hi-24s-switch","title":"Huawei S6720-30L-HI-24S Switch","description":"\u003ch4\u003eS6720-30L-HI-24S Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-30L-HI-24S with \u003cstrong\u003e24*10GE SFP+ ports, 4*40GE QSFP+ ports, and 2 100G QSFP28, power module slots, hot-swappable power modules are optional: 1*AC+1*DC, 1*AC or 1*DC. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei S6720-HI series full-featured 10 GE routing switches are Huawei’s first IDN-ready fixed switches that provide 10 GE downlink ports and 40 GE\/100 GE uplink ports.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*100GE\/40GE QSFP28 ports\u003c\/p\u003e\n\u003cp\u003e4*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 4 GB\u003c\/p\u003e\n\u003cp\u003eFlash 1GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_2031bab2-958f-46ad-89ae-41375324302d_600x600.png?v=1735280083\" alt=\"S6720-30L-HI-24SAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e 24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 100GE\/40GE QSFP28 ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module (QSFP-100G-ER4 not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP28 to QSFP28 high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003cp\u003eThe default rate is 100 Gbit\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-40HA-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-40HA-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ por\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Attributes of a QSFP28 optical port\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" summary=\"\" class=\"idp-ltr-html-tb-normal\" id=\"EN-US_CONCEPT_0177095496__EN-US_CONCEPT_0177095496_mMcCpPsS_tab_dc_s_hw_00229203\" border=\"1\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" id=\"mcps1.7.16.6.4.3.5.2.2.3.1.1\"\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" id=\"mcps1.7.16.6.4.3.5.2.2.3.1.2\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.1\"\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.2\"\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.1\"\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.2\"\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.1\"\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.16.6.4.3.5.2.2.3.1.2\"\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e61.42 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 445.6 mm (1.72 in. x 17.4 in. x 17.54 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.9 kg (21.83 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 100GE QSFP28 ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e232 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e138 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02351MXR\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 100G port compatible with 40G\/25G\/10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×100G QSFP28 ports, backward compatible with 40G\/25G\/10G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various data center\/enterprise power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for high-frequency trading?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.22ms, hardware forwarding rate 720 Mpps, supports RoCE v2 lossless network—perfect for high-frequency trading\/AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What is the advantage of 6x100G uplink ports compared to similar products?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 600Gbps total uplink bandwidth, multi-link redundancy, flexible for long-distance interconnection—more reliable than 4x100G uplink products.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762454093976,"sku":"02351MXR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-30L-HI-24S-2.jpg?v=1735280652"},{"product_id":"huawei-s6720-50l-hi-48s-switch","title":"Huawei S6720-50L-HI-48S Switch","description":"\u003ch4\u003eS6720-50L-HI-48S Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-50L-HI-48S with \u003cstrong\u003e48*10 GE SFP+, 6*40GE QSFP+ or 44*10GE SFP+, 4* 40GE QSFP+, and 2*100GE QSFP28,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eS6720-HI series full-featured 10 GE routing switches are Huawei’s first IDN-ready fixed switches to provide 10 GE downlink ports as well as 40 GE and 100 GE uplink ports.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*100GE\/40GE QSFP28 ports\u003c\/p\u003e\n\u003cp\u003e4*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2 GB\u003c\/p\u003e\n\u003cp\u003eFlash 1GB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_1_76af0d23-7e79-467e-a53e-54f576cbad08_600x600.png?v=1735281264\" alt=\"S6720-50L-HI-48SAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e48 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 40GE\/100GE QSFP28 ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003eQSFP28 optical module (QSFP-100G-ER4 not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP28 to QSFP28 high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP28 to QSFP28 AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA QSFP28 optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003cp\u003eThe default rate is 40 Gbit\/s, and you can run the set device port-config-mode 100g-port enable command to change the rate to 100 Gbit\/s. When you run the command on either of the ports, both ports are configured to work at the rate of 100 Gbit\/s simultaneously.\u003c\/p\u003e\n\u003cp\u003eAfter the rate is changed from 40 Gbit\/s to 100 Gbit\/s, ports 10GE0\/0\/45 to 10GE0\/0\/48 become unavailable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port cannot be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-40HA-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-40HA-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Attributes of a QSFP28 optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e54.65 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 445.6 mm (1.72 in. x 17.4 in. x 17.54 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10.2 kg (22.49 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe last 36 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 100GE QSFP28 ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e279 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e194 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 65 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02351MXN\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 100G port compatible with 40G\/25G\/10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×10G SFP+ (all-optical) + 2×100G QSFP28 ports, backward compatible with 40G\/25G\/10G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What power supply modes does it support? Is there redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports AC (100-240V) \/ DC (-48V~-60V) dual modes + 1+1 dual power redundancy—adapts to various data center\/enterprise power architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for high-frequency trading?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.2ms, hardware forwarding rate 960 Mpps, supports RoCE v2 lossless network—perfect for high-frequency trading\/AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and clustering technologies?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + CSS clustering (max 2 switches)—meets large-scale expansion and high-availability needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for large data centers with high-density access needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than multi-device cascading solutions, 48x10G access + 100G uplink, 55-year MTBF—ideal for large DC heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762480242840,"sku":"02351MXN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-50L-HI-48S-2.jpg?v=1735281632"},{"product_id":"huawei-s6720s-26q-ei-24s-ac-switch","title":"Huawei S6720S-26Q-EI-24S-AC Switch","description":"\u003ch4\u003eS6720S-26Q-EI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-26Q-EI-24S-AC with\u003cstrong\u003e 24*10GE SFP+ ports, 2*40GE QSFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-EI has industry-leading performance, provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S6720S-26Q-EI-24S-ACAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_30c7922b-13f3-4d4a-a62e-03ad28b10d73_600x600.png?v=1735282522\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003eW0PSA1701 (170 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003eES5M0PSD1700 (170 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003eW0PSA1701 (170 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003eES5M0PSD1700 (170 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMonitoring port\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis port is reserved and cannot be used currently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e69.53 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 222.3 mm (1.75 in. x 17.4 in. x 8.75 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 44.4 mm x 442.0 mm x 250.0 mm (1.75 in. x 17.4 in. x 9.84 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5.4 kg (11.91 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e143.4 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e108.59 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 67.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350MTR\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 100G port compatible with 40G\/25G\/10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 2×100G QSFP28 ports, backward compatible with 40G\/25G\/10G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range and redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V) + 1+1 dual power redundancy—perfect for enterprise\/data center conventional power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.25ms, hardware forwarding rate 600 Mpps, supports RoCE v2 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and virtualization technologies (MPLS\/VXLAN)?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + MPLS\/VRF\/VXLAN—meets multi-tenant isolation and large-scale expansion needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with high-bandwidth needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 100G switches, 50-year MTBF, AC compatibility—ideal for mid-large heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762499182744,"sku":"02350MTR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-26Q-EI-24S-AC-2.jpg?v=1735282751"},{"product_id":"huawei-s6720s-26q-ei-24s-dc-switch","title":"Huawei S6720S-26Q-EI-24S-DC Switch","description":"\u003ch4\u003eS6720S-26Q-EI-24S-DC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-26Q-EI-24S-DC with \u003cstrong\u003e24*10GE SFP+ ports, 2*40GE QSFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-EI has industry-leading performance, and provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_1_d332fef6-249f-4ffd-8a1c-0d52a0c3b197_600x600.png?v=1735283603\" alt=\"S6720S-26Q-EI-24S-DC Appearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003eW0PSA1701 (170 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003eES5M0PSD1700 (170 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003eW0PSA1701 (170 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003eES5M0PSD1700 (170 W DC Power Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMonitoring port\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThis port is reserved and cannot be used currently.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e69.53 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 222.3 mm (1.75 in. x 17.4 in. x 8.75 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 44.4 mm x 442.0 mm x 250.0 mm (1.75 in. x 17.4 in. x 9.84 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5.2 kg (11.47 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e126.3 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e101.31 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 67.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350MTS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 100G port compatible with 40G\/25G\/10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 2×100G QSFP28 ports, backward compatible with 40G\/25G\/10G modules via adapters—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support DC power supply? What's the voltage range and redundancy?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports -48V~-60V DC power (compatible with -36V~-72V) + 1+1 dual power redundancy—ideal for data center centralized power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI supercomputing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.25ms, hardware forwarding rate 600 Mpps, supports RoCE v2 lossless network—perfect for AI supercomputing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and virtualization technologies (MPLS\/VXLAN)?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) + MPLS\/VRF\/VXLAN—meets multi-tenant isolation and large-scale expansion needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large data centers with high-reliability needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 100G switches, 50-year MTBF, DC redundancy—ideal for mid-large heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45762506752152,"sku":"02350MTS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-26Q-EI-24S-DC-2.jpg?v=1735283876"},{"product_id":"huawei-s6720s-16x-li-16s-ac-switch","title":"Huawei S6720S-16X-LI-16S-AC Switch","description":"\u003ch4\u003eS6720S-16X-LI-16S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-16X-LI-16S-AC with \u003cstrong\u003e16*10GE SFP+ ports ,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-LI series switches (S6720-LI) are next-generation simplified 10GE fixed switches and can be used as 10GE access switches on campus networks and data center networks. The S6720-LI provides line-rate 10GE access ports and 40GE uplink ports. In addition, the S6720-LI delivers a wide variety of services, comprehensive security control policies, and various QoS features to help customers build scalable, reliable, manageable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e16*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6720S-16X-LI-16S-ACAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-16X-LI-16S-ACAppearance_and_Structure_600x600.png?v=1735627564\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSixteen 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39.2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.1 kg (9.04 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e67.9 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e45.2 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 46.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010688\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the enhanced features compared to the standard version?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enhanced ACL (4000+ rules), link self-healing suggestions, basic traffic statistics, and improved EMI protection—more suitable for SMB growth needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 25G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 16×10G SFP+ (all-optical) + 4×25G SFP28 ports, backward compatible with 10G SFP+ modules—no need to replace existing hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? Can it be used in small offices?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power, perfect for small offices—no need to modify the existing power system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it easy to install and manage for non-IT staff?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! Compact design (2.6kg) for easy installation, and web-based visual management with self-healing suggestions—non-IT staff can operate it easily.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small businesses with 50-150 employees?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end switches, enhanced features, 16x10G+4x25G—ideal for growing SMBs with low-cost all-optical needs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45774589034648,"sku":"98010688","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-16X-LI-16S-AC-2.jpg?v=1735523047"},{"product_id":"huawei-s6720s-32x-li-32s-ac-switch","title":"Huawei S6720S-32X-LI-32S-AC Switch","description":"\u003ch4\u003eS6720S-32X-LI-32S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-32X-LI-32S-AC with \u003cstrong\u003e32*10GE SFP+ ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-LI series switches (S6720-LI) are next-generation simplified 10GE fixed switches and can be used as 10GE access switches on campus networks and data center networks. The S6720-LI provides line-rate 10GE access ports and 40GE uplink ports. In addition, the S6720-LI delivers a wide variety of services, comprehensive security control policies, and various QoS features to help customers build scalable, reliable, manageable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cimg style=\"float: none;\" alt=\"S6720S-32X-LI-32S-ACAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_1_562e763f-e538-429f-836e-1b919df4cc77_600x600.png?v=1735523589\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThirty-two 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"width: 100%; height: 1927.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003cth style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 55.2px;\"\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 55.2px;\"\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 55.2px;\"\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 55.2px;\"\u003e\n\u003cp\u003e42.8 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 55.2px;\"\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 55.2px;\"\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.2px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 55.2px;\"\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 55.2px;\"\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 165.2px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 165.2px;\"\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 165.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e4.3 kg (9.48 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 94.4px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 94.4px;\"\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 94.4px;\"\u003e\n\u003cp\u003e108.5 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.8px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 74.8px;\"\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 74.8px;\"\u003e\n\u003cp\u003e71.8 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 149.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 149.6px;\"\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 149.6px;\"\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 526.8px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 526.8px;\"\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 526.8px;\"\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.8px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 74.8px;\"\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 74.8px;\"\u003e\n\u003cp\u003e\u0026lt; 46.4 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 86.8px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 86.8px;\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 86.8px;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.6px;\"\u003e\n\u003ctd style=\"width: 31.9024%; height: 35.6px;\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.6159%; height: 35.6px;\"\u003e\n\u003cp\u003e98010694\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What are the enhanced features compared to the standard version?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Enhanced ACL (8000+ rules), NetStream traffic analysis, improved EMI protection, and link self-healing suggestions—more suitable for SME business expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 25G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×10G SFP+ (all-optical) + 4×25G SFP28 ports, backward compatible with 10G SFP+ modules—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for light AI scenarios?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.5ms, hardware forwarding rate 300 Mpps—ideal for light AI data processing and HD video transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for SMEs needing enhanced 25G all-optical networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end 25G all-optical switches, AC compatibility, enhanced features—ideal for SME low-cost enhanced 25G networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45770845978776,"sku":"98010694","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-32X-LI-32S-AC-2.jpg?v=1735523787"},{"product_id":"huawei-s6720-16x-li-16s-ac-switch","title":"Huawei S6720-16X-LI-16S-AC Switch","description":"\u003ch4\u003eS6720-16X-LI-16S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-16X-LI-16S-AC switch with \u003cstrong\u003e16*10GE SFP+ ports,1xAC power input fixed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eHuawei S6720-LI series switches are next-generation simplified all-10GE fixed switches and can be used for 10GE access on campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e16 10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cimg alt=\"S6720-16X-LI-16S-AC appearance\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-16X-LI-16S-AC_appearance_600x600.png?v=1735610821\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSixteen 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39.2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.1 kg (9.04 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e67.9 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e45.2 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 46.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010687\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 25G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 16×10G SFP+ (all-optical) + 4×25G SFP28 ports, backward compatible with 10G SFP+ modules—no need to replace existing 10G hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? Can it be used in small offices?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power, perfect for small offices\/cubicles—no need to modify the existing power system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for HD video conferences?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.6ms, hardware forwarding rate 200 Mpps—smooth for HD video conferences and large file transfers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it easy to install and manage for non-IT staff?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! Compact design (2.6kg) for easy installation, and web-based visual management—non-IT staff can operate it with simple training.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small and medium-sized businesses with 50-150 employees?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end switches, 16x10G access + 4x25G uplink—ideal for SMBs with growth needs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45770906271896,"sku":"98010687","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-16X-LI-16S-AC-2.jpg?v=1735525902"},{"product_id":"huawei-s6720-32x-li-32s-ac-switch","title":"Huawei S6720-32X-LI-32S-AC Switch","description":"\u003ch4\u003eS6720-32X-LI-32S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32X-LI-32S-AC with \u003cstrong\u003e32*10GE SFP+ ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-LI series switches (S6720-LI) are next-generation simplified 10GE fixed switches and can be used as 10GE access switches on campus networks and data center networks. The S6720-LI provides line-rate 10GE access ports and 40GE uplink ports. In addition, the S6720-LI delivers a wide variety of services, comprehensive security control policies, and various QoS features to help customers build scalable, reliable, manageable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/download_15ccff26-3952-4888-b880-53ae24485e87_600x600.png?v=1735526381\" alt=\"S6720-32X-LI-32S-ACAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThirty-two 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e42.8 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.3 kg (9.48 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e108.5 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e71.8 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 46.4 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010693\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 25G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×10G SFP+ (all-optical) + 4×25G SFP28 ports, backward compatible with 10G SFP+ modules—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for light AI scenarios?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.5ms, hardware forwarding rate 300 Mpps—ideal for light AI data processing and HD video transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 25G SFP28 ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 10km with single-mode transceivers—ideal for short-to-medium distance campus\/SME interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for SMEs needing 25G all-optical networking?\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end 25G all-optical switches, AC compatibility, 45-year MTBF—ideal for SME low-cost 25G networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45770945003672,"sku":"98010693","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32X-LI-32S-AC-2.jpg?v=1735526587"},{"product_id":"huawei-s6720-26q-li-24s-ac-switch","title":"Huawei S6720-26Q-LI-24S-AC Switch","description":"\u003ch4\u003eS6720-26Q-LI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-26Q-LI-24S-AC switch with \u003cstrong\u003e24*10GE SFP+ ports\u003c\/strong\u003e, \u003cstrong\u003e2*40GE QSFP+ ports,1xAC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-LI series switches (S6720-LI) are next-generation simplified 10GE fixed switches and can be used as 10GE access switches on campus networks and data center networks. The S6720-LI provides line-rate 10GE access ports and 40GE uplink ports. In addition, the S6720-LI delivers a wide variety of services, comprehensive security control policies, and various QoS features to help customers build scalable, reliable, manageable, and secure campus and data center networks.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32 10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2 40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6720-26Q-LI-24S-AC-Appearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-26Q-LI-24S-AC-appearance_600x600.png?v=1735527192\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an RPS cable, which is not hot swappable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Attributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39.2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ± 6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 225.0 mm (1.72 in. x 17.4 in. x 8.86 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 234.4 mm (1.72 in. x 17.4 in. x 9.23 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.2 kg (9.26 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100.2 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e67.1 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 46.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010684\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 40G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 2×40G QSFP+ ports, backward compatible with 10G SFP+ modules—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for HD video transmission?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.6ms, hardware forwarding rate 240 Mpps—ideal for HD video transmission and office data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 20km with single-mode transceivers—ideal for short-to-medium distance campus\/SME interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small and medium-sized enterprises needing all-optical networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end all-optical switches, AC compatibility, 45-year MTBF—ideal for SME low-cost all-optical networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45770989830296,"sku":"98010684","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-26Q-LI-24S-AC-2.jpg?v=1735527396"},{"product_id":"huawei-s6720-26q-si-24s-ac-switch","title":"Huawei S6720-26Q-SI-24S-AC Switch","description":"\u003ch4\u003eS6720-26Q-SI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-26Q-SI-24S-AC with \u003cstrong\u003e24*10GE SFP+ ports\u003c\/strong\u003e, \u003cstrong\u003e2*40GE QSFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"float: none;\" alt=\"S6720-26Q-SI-24S-AC Appearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-26Q-SI-24S-AC-appearance_600x600.png?v=1735528233\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-046A-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable style=\"width: 100%;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 54.7776%;\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e41.9 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e8.9 kg (19.62 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e97 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e68.4 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e\u0026lt; 57 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45.0015%;\"\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 54.7776%;\"\u003e\n\u003cp\u003e98010690\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support 10G modules on the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! The 2x40G QSFP+ ports are backward compatible with 10G SFP+ modules via adapters—flexible for network upgrade without replacing hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance for 10G and 40G ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 10G SFP+ ports: up to 40km (single-mode); 40G QSFP+ ports: up to 40km (single-mode)—ideal for long-distance campus\/SME interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for small data center core networking with AC power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! 24x10G access + 2x40G uplink, 1.28Tbps capacity, and AC power compatibility make it perfect for small DC core layers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Supports iStack stacking (max 9 switches) and optional dual power redundancy—ensures scalability and non-stop service for growing SMEs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the power consumption and noise level?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Typical 120W, max 150W (energy-saving algorithm); ≤54dB(A) noise—friendly for office\/small server room deployment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45774665777304,"sku":"98010690","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-26Q-SI-24S-AC-2.jpg?v=1735528462"},{"product_id":"huawei-s6720-32c-pwh-si-switch","title":"Huawei S6720-32C-PWH-SI Switch","description":"\u003ch4\u003eS6720-32C-PWH-SI Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32C-PWH-SI with \u003cstrong\u003e24*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port),4*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports \u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S6720-32C-PWH-SIAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/6720-32C-PWH-SI-appearance_600x600.png?v=1735530236\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable border=\"1\" id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_tab_dc_s_hw_00234201\" class=\"idp-ltr-html-tb-normal\" summary=\"\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1535667348183514\"\u003e\n\u003cth id=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p579675017183514\"\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth id=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p42472305183514\"\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row619483749183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1627217278183514\"\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p478493831183514\"\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1530525872183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1375236038183514\"\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p546710074183514\"\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1211135083183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1314095301183514\"\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p351403057183514\"\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Maximum transmission distances of different cables on MultiGE ports\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"5\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e24*100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eLeft 16x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRight 8x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e22.7 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 580 W AC or 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing 650 W DC or 1150 W AC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen 1150 W power modules are installed, they stretch out from the chassis. Therefore, the total depth of the switch changes to 541.1 mm (21.3 in.).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.1 kg (17.86 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC or 580 W AC power modules:\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 125.6 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1017.2 W (system power consumption: 278 W, PoE: 739.2 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsing 1150 W AC or 1000 W AC power modules:\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 125.6 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1735 W (system power consumption: 295 W, PoE: 1440 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC or 580 W AC power modules: 106.9 W (without card and PoE)\u003c\/li\u003e\n\u003cli\u003eUsing 1150 W AC or 1000 W AC power modules: 121.6 W (without card and PoE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 62.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010720\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eFrequently asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 960W, max 60W per port (802.3bt PoE++)—supports 32 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many 40G uplink ports does it have? What's the max transmission distance?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 4×40G QSFP+ uplink ports, up to 40km with single-mode transceivers—ideal for long-distance campus\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for 32 high-power PTZ cameras and Wi-Fi 6E APs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! 60W PoE++ and 960W total power perfectly support high-power devices like PTZ cameras and Wi-Fi 6E APs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for smart campuses with dense high-power terminals?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 50% cheaper than traditional power+network solutions, 40G high-speed uplink, and enterprise reliability—ideal for dense terminal PoE networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771108876440,"sku":"98010720","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-PWH-SI-2.jpg?v=1735539954"},{"product_id":"huawei-s6720-32c-pwh-si-ac-switch","title":"Huawei S6720-32C-PWH-SI-AC Switch","description":"\u003ch4\u003eS6720-32C-PWH-SI-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32C-PWH-SI-AC with \u003cstrong\u003e24*100M\/1G\/2.5G\/5G\/10GBASE-T ports, 4*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port))\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports \u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-PWH-SI-AC-appearance_600x600.png?v=1735531857\" alt=\"S6720-32C-PWH-SI-ACAppearance and Structure\" style=\"float: none;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e Attributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable border=\"1\" id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_tab_dc_s_hw_00234201\" class=\"idp-ltr-html-tb-normal\" summary=\"\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1535667348183514\"\u003e\n\u003cth id=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p579675017183514\"\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth id=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p42472305183514\"\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row619483749183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1627217278183514\"\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p478493831183514\"\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1530525872183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1375236038183514\"\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p546710074183514\"\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1211135083183514\"\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\" width=\"22.52%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1314095301183514\"\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\" width=\"77.48%\" valign=\"top\" class=\"idp-ltr-html-cellrowborder\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p351403057183514\"\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Maximum transmission distances of different cables on MultiGE ports\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"5\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e24*100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eLeft 16x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eRight 8x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 m\u003c\/p\u003e\n\u003cdiv\u003eOnly the APs listed below are supported if the transmission distance is longer than 100 m:\n\u003cul\u003e\n\u003cli\u003eAP7052DN\/AP7152DN\u003c\/li\u003e\n\u003cli\u003eAP6052DN\u003c\/li\u003e\n\u003cli\u003eAP8082DN\/AP8182DN\u003c\/li\u003e\n\u003cli\u003eAP7052DE\u003c\/li\u003e\n\u003cli\u003eAP7060DN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eTechnical specifications\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e22.7 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 580 W AC or 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing 650 W DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.1 kg (20.06 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC or 580 W AC power modules:\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 125.6 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1017.2 W (system power consumption: 278 W, PoE: 739.2 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsing 1000 W AC power modules:\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 125.6 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1735 W (system power consumption: 295 W, PoE: 1440 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC or 580 W AC power modules: 106.9 W (without card and PoE)\u003c\/li\u003e\n\u003cli\u003eUsing 1000 W AC power modules: 121.6 W (without card and PoE)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 62.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010719\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 960W, max 60W per port (802.3bt PoE++)—supports 32 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), optional dual power redundancy—perfect for enterprise\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many 40G uplink ports does it have? What's the max transmission distance?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 4×40G QSFP+ uplink ports, up to 40km with single-mode transceivers—ideal for long-distance campus\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for 32 high-power PTZ cameras and Wi-Fi 6E APs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! 60W PoE++ and 960W total power perfectly support high-power devices like PTZ cameras and Wi-Fi 6E APs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for smart campuses with AC power and dense terminals?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 50% cheaper than traditional power+network solutions, AC compatibility, enterprise reliability—ideal for dense terminal PoE networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771216257176,"sku":"98010719","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-PWH-SI-AC-2.jpg?v=1735532160"},{"product_id":"huawei-s6720-32c-si-ac-switch","title":"Huawei S6720-32C-SI-AC Switch","description":"\u003ch4\u003eS6720-32C-SI-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32C-SI-AC with \u003cstrong\u003e24*100M\/1000M\/2.5G\/5G\/10G BASE-T ports, 4*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports \u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-SI-AC-appearance_600x600.png?v=1735539601\" alt=\"S6720-32C-SI-ACAppearance and Structure\" style=\"float: none;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" summary=\"\" class=\"idp-ltr-html-tb-normal\" id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_tab_dc_s_hw_00234201\" border=\"1\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1535667348183514\"\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" id=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p579675017183514\"\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" id=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p42472305183514\"\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row619483749183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1627217278183514\"\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p478493831183514\"\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1530525872183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1375236038183514\"\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p546710074183514\"\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1211135083183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1314095301183514\"\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p351403057183514\"\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Maximum transmission distances of different cables on MultiGE ports\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"4\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e24*100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e27.4 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.7 kg (19.18 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e117.62 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e93 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 62.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010715\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×10G SFP+ (all-optical) + 4×40G QSFP+ ports—ideal for mid-data center high-density access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), dual power redundancy—perfect for traditional data center\/enterprise power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing nodes?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.3ms, hardware forwarding rate 480 Mpps, supports RoCE v2 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance mid-data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-sized data centers with traditional AC power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 38% cheaper than high-end 40G switches, 50-year MTBF, AC compatibility—ideal for mid-sized heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771607834776,"sku":"98010715","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-SI-AC-2.jpg?v=1735540004"},{"product_id":"huawei-s6720-32c-si-dc-switch","title":"Huawei S6720-32C-SI-DC Switch","description":"\u003ch4\u003eS6720-32C-SI-DC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32C-SI-DC with \u003cstrong\u003e24*100M\/1000M\/2.5G\/5G\/10G BASE-T ports, 4*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports \u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-SI-DC-appearance_600x600.png?v=1735540462\" alt=\"S6720-32C-SI-DCAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable cellpadding=\"4\" cellspacing=\"0\" summary=\"\" class=\"idp-ltr-html-tb-normal\" id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_tab_dc_s_hw_00234201\" border=\"1\"\u003e\n\u003cthead align=\"left\"\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1535667348183514\"\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" id=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p579675017183514\"\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" id=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p42472305183514\"\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row619483749183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1627217278183514\"\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p478493831183514\"\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1530525872183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1375236038183514\"\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p546710074183514\"\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_row1211135083183514\"\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"22.52%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.1\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p1314095301183514\"\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"idp-ltr-html-cellrowborder\" valign=\"top\" width=\"77.48%\" headers=\"mcps1.7.12.11.4.3.3.3.2.3.1.2\"\u003e\n\u003cp id=\"EN-US_CONCEPT_0177095399__EN-US_CONCEPT_0177095399_mMcCpPsS_en-us_concept_0177095382_p351403057183514\"\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Maximum transmission distances of different cables on MultiGE ports\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"4\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e24*100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e24x10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e27.4 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.7 kg (19.18 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e117.62 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e93 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 62.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010716\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×10G SFP+ (all-optical) + 4×40G QSFP+ ports—ideal for mid-data center high-density access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support DC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports -48V~-60V DC power (compatible with -36V~-72V), dual power redundancy—perfect for data center centralized power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing nodes?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.3ms, hardware forwarding rate 480 Mpps, supports RoCE v2 lossless network—ideal for AI\/high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance mid-data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-sized data centers with high-reliability needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 38% cheaper than high-end 40G switches, 50-year MTBF, DC redundancy—ideal for mid-sized heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771641716888,"sku":"98010716","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32C-SI-DC-2.jpg?v=1735540780"},{"product_id":"huawei-s6720-32x-si-32s-ac-switch","title":"Huawei S6720-32X-SI-32S-AC Switch","description":"\u003ch4\u003eS6720-32X-SI-32S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-32X-SI-32S-AC with \u003cstrong\u003e32*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates. In addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cp\u003e\u003cimg style=\"float: none;\" alt=\"S6720-32X-SI-32S-AC Appearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32X-SI-32S-AC-appearance_600x600.png?v=1735541783\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThirty-two 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-046A-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46.7 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.9 kg (19.62 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e104.6 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e72.6 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 60.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010695\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? Is the 25G port compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×10G SFP+ (all-optical) + 4×25G SFP28 ports, backward compatible with 10G SFP+ modules—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI labs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.35ms, hardware forwarding rate 360 Mpps, supports lossless transmission—ideal for AI labs\/4K video studios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 25G SFP28 ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 10km with single-mode transceivers—ideal for long-distance campus\/SME interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for SMEs needing all-optical 25G networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end all-optical switches, AC compatibility, 50-year MTBF—ideal for SME heavy-load all-optical networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771710464152,"sku":"98010695","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-32X-SI-32S-AC-2.jpg?v=1735541982"},{"product_id":"huawei-s6720-52x-pwh-si-switch","title":"Huawei S6720-52X-PWH-SI Switch","description":"\u003ch4\u003eS6720-52X-PWH-SI Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-52X-PWH-SI switch with \u003cstrong\u003e48*100M\/1G\/2.5G\/5G\/10GBase-T Ethernet ports, 4*10GE SFP+, 1 AC equipped, PoE++, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates.\u003c\/p\u003e\n\u003cp\u003eIn addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-52X-PWH-SI-appearance_600x600.png?v=1735542544\" alt=\"S6720-52X-PWH-SIAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e Attributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaximum transmission distances of different cables on MultiGE ports\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"4\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e48 x 100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e48 x 2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e48 x 5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e48 x 10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e35.1 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing 1150 W AC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen 1150 W power modules are installed, they stretch out from the chassis. Therefore, the total depth of the switch changes to 541.1 mm (21.3 in.).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7 kg (15.43 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE or 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 207.4 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 940 W (system power consumption: 200.8 W, PoE: 739.2 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsing 1150 W AC or 1000 W AC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 236.8 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1724.4 W (system power consumption: 284.4 W, PoE: 1440 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e159.5 W (without PoE)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 66.4 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010743\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 1440W, max 60W per port (802.3bt PoE++)—supports 48 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many 25G uplink ports does it have? Is it compatible with 10G modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 4×25G SFP28 uplink ports, backward compatible with 10G SFP+ modules—flexible for network upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for 4K\/8K video transmission?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.4ms, hardware forwarding rate 220 Mpps—perfect for 4K\/8K video transmission and real-time data processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for smart campuses with dense high-power terminals?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 55% cheaper than traditional power+network solutions, 25G high-speed uplink, and enterprise reliability—ideal for dense terminal scenarios.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771718164632,"sku":"98010743","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-52X-PWH-SI-2.jpg?v=1735544130"},{"product_id":"huawei-s6720-56c-pwh-si-ac-switch","title":"Huawei S6720-56C-PWH-SI-AC Switch","description":"\u003ch4\u003eS6720-56C-PWH-SI-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-56C-PWH-SI-AC with \u003cstrong\u003e32 1000MGBASE-T ports, 16*100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port), 4*10GE SFP+ ports, 1*AC equipped PoE++,2*POE power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates.\u003c\/p\u003e\n\u003cp\u003eIn addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32*PoE++ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e16*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-56C-PWH-SI-AC-appearance_600x600.png?v=1735543795\" alt=\"S6720-56C-PWH-SI-AC Appearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThirty-two PoE++ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSixteen PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e Attributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaximum transmission distances of different cables on MultiGE ports\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"4\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e23.9 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±6 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 580 W AC or 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing 650 W DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.3 kg (20.5 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC power modules or 580 W AC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 120.5 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1068.1 W (system power consumption: 328.9 W, PoE: 739.2 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsing 1000 W AC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 120.5 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1995.4 W (system power consumption: 555.4 W, PoE: 1440 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e91.01 W (not providing the PoE function, without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 60.5 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010727\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 1440W, max 60W per port (802.3bt PoE++)—supports 48 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), optional dual power redundancy—perfect for enterprise\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many 10G uplink ports does it have? What's the max transmission distance?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 8×10G SFP+ uplink ports, up to 100km with single-mode transceivers—ideal for long-distance campus interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for 48 high-power PTZ cameras and Wi-Fi 6E APs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! 60W PoE++ and 1440W total power perfectly support high-power devices like PTZ cameras and Wi-Fi 6E APs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for large smart campuses with AC power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 55% cheaper than traditional power+network solutions, AC compatibility, enterprise reliability—ideal for dense terminal PoE networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771741233304,"sku":"98010727","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-56C-PWH-SI-AC-2.jpg?v=1735544161"},{"product_id":"huawei-s6720-56c-pwh-si-switch","title":"Huawei S6720-56C-PWH-SI Switch","description":"\u003ch4\u003eS6720-56C-PWH-SI Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cbr\u003eHuawei S6720-56C-PWH-SI switch with \u003cstrong\u003e32*1000MGBASE-T ports, 16* 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port), 4*10GE SFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports. It can be used to provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates.\u003c\/p\u003e\n\u003cp\u003eIn addition, S6720-SI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure campus and data center networks.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e32*PoE++ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e16*PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6720-56C-PWH-SI Appearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-56C-PWH-SI-appearance_600x600.png?v=1735544578\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThirty-two PoE++ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSixteen PoE++ 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T ports (MultiGE port)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eThe four 10GE SFP+ ports on the front panel cannot be used simultaneously with ports on the rear card (except the 4-port 10GE rear card).\u003c\/p\u003e\n\u003cdiv\u003eIf a rear card other than a 4-port 10GE rear card is installed in the switch, only the ports on the front panel can be used by default.\n\u003cul\u003e\n\u003cli\u003eV200R011 version: To use the port on the rear card, run the set device port-on-card enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003cli\u003eV200R012 and later versions: To use the port on the rear card, run the undo set device port-config-mode port-on-board enable command. Then the four 10GE SFP+ ports on the front panel cannot be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCards supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q02Q00\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e13\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e580 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e650 W DC PoE power module\u003c\/li\u003e\n\u003cli\u003e1150 W AC PoE power module\u003c\/li\u003e\n\u003cli\u003e1000 W AC PoE power module (applicable in V200R013C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e Attributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 100M\/1000M\/2.5GE\/5GE\/10GE BASE-T port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3u, IEEE802.3ab, IEEE802.3bz, IEEE802.3an, mgbase-t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking Mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100\/1000\/2500\/5000\/10000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMaximum transmission distances of different cables on MultiGE ports\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003e\n\u003cp\u003eCable Type (6-a-1 Bundle)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"4\"\u003e\n\u003cp\u003eMultiGE Port (Different Rates)\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 100M\/1000M\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 2.5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 5GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e16 x 10GE\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e unshielded twisted pair (Cat5e UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e55 m\u003c\/li\u003e\n\u003cli\u003e100 m (6-a-1 bundle only for the first 30 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 5e shielded twisted pair (Cat5e STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 unshielded twisted pair (Cat6 UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6 shielded twisted pair (Cat6 STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A unshielded twisted pair (Cat6A U\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003cp\u003eNot recommended due to high risk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A foiled\/unshielded twisted pair (Cat6A F\/UTP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 6A shielded twisted pair (Cat6A STP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCategory 7 twisted pair (Cat7)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e23.9 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±6 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 580 W AC or 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing 650 W DC or 1150 W AC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen 1150 W power modules are installed, they stretch out from the chassis. Therefore, the total depth of the switch changes to 541.1 mm (21.3 in.).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.3 kg (18.3 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny MultiGE, 10GE SFP+, or 40GE QSFP+ ports (a maximum of 16 physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing 650 W DC power modules or 580 W AC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 120.5 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1068.1 W (system power consumption: 328.9 W, PoE: 739.2 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsing 1150 W AC or 1000 W AC power modules\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 120.5 W (without card)\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 1995.4 W (system power consumption: 555.4 W, PoE: 1440 W, without card)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e91.01 W (not providing the PoE function, without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 62.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010730\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 1440W, max 60W per port (802.3bt PoE++)—supports 48 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many 10G uplink ports does it have? What's the max transmission distance?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 8×10G SFP+ uplink ports, up to 100km with single-mode transceivers—ideal for long-distance campus interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for 48 high-power PTZ cameras and Wi-Fi 6E APs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! 60W PoE++ and 1440W total power perfectly support high-power devices like PTZ cameras and Wi-Fi 6E APs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for large smart campuses with dense terminals?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 55% cheaper than traditional power+network solutions, with enterprise reliability—ideal for dense terminal PoE networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45771780554904,"sku":"98010730","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-56C-PWH-SI-2.jpg?v=1735544752"},{"product_id":"huawei-s6720s-26q-si-24s-ac-switch","title":"Huawei S6720S-26Q-SI-24S-AC Switch","description":"\u003ch4\u003eS6720S-26Q-SI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720S-26Q-SI-24S-AC with \u003cstrong\u003e24*10GE SFP+ ports, 2*40GE QSFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-SI is one of the multigigabit fixed switches with the highest performance in the industry, providing line-rate multigigabit 100M\/1G\/2.5G\/5G\/10G access ports and 40GE uplink ports, which provide high-speed access for APs and 10 Gbit\/s access to high-density servers or function as a core\/aggregation switch on a campus network to provide 40 Gbit\/s rates.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6720S-26Q-SI-24S-ACppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-26Q-SI-24S-AC-ppearance_and_Structure_600x600.png?v=1735629223\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable in V200R012C00 and later versions:\u003c\/p\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module: FAN-046A-B Fan Module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003e150 W AC power module\u003c\/li\u003e\n\u003cli\u003e150 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e41.9 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (including package)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.9 kg (19.62 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 2 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-36 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e97 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e68.4 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 57 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC power modules configured: 0-5000 m (0-16404 ft.)\u003c\/li\u003e\n\u003cli\u003eDC power modules configured: 0-2000 m (0-6562 ft.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010691\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 2×40G QSFP+ ports—ideal for SME high-density 10G access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), perfect for SME\/campus conventional power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI labs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.4ms, hardware forwarding rate 360 Mpps, supports lossless transmission—ideal for AI labs\/4K video studios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance campus\/SME interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for SMEs needing all-optical networking?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end all-optical switches, AC compatibility, 50-year MTBF—ideal for SME heavy-load all-optical networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45774997160088,"sku":"98010691","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720S-26Q-LI-24S-AC-2.jpg?v=1735629614"},{"product_id":"huawei-s6700-24-ei-switch","title":"Huawei S6700-24-EI Switch","description":"\u003ch4\u003eS6700-24-EI Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6700-24-EI with \u003cstrong\u003e24*10GE SFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe S6700 has industry-leading performance and provides up to 24 or 48 line-speed 10 GE ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6700 provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 512MB\u003c\/p\u003e\n\u003cp\u003eFlash 64MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6700-24-EIAppearance_and_Structure_600x600.png?v=1735630678\" alt=\"S6700-24-EI Appearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (applicable in V200R001C01 and later versions, only 1000 Mbit\/s supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module (applicable in V200R005C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e5 m SFP+ high-speed copper cables (applicable in V200R005C02)\u003c\/li\u003e\n\u003cli\u003e10 m SFP+ high-speed copper cable (applicable in V200R001C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m AOC cables (applicable in V200R003C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eBefore installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eCX7E1FANA fan module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eCX7E1FANA fan module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e500 W AC power module\u003c\/li\u003e\n\u003cli\u003e500 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e500 W AC power module\u003c\/li\u003e\n\u003cli\u003e500 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e64 MB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e34.54 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEmpty: ≤ 5 kg (11.02 lb)\u003c\/li\u003e\n\u003cli\u003eFully configured: ≤ 8.5 kg (18.74 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports (a maximum of eight physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e153.6 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eThe operating temperature of the switch is -5°C to +45°C (23°F to 113°F) when it uses SFP+ optical modules with 40 km or longer transmission distances.\u003c\/li\u003e\n\u003cli\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 55 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02352768\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? What's the uplink port type?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×Gigabit RJ45 ports (for access) + 4×10G SFP+ ports (for uplink\/expansion)—ideal for compact high-density enterprise networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for small data center access?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 66 Mpps, latency ≤0.9ms—perfect for small DC server access and real-time data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—grows with your enterprise needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for cross-region branch-to-headquarters interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it a cost-effective compact classic model for mid-large enterprise branches?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than full-port switches, 50-year MTBF, and proven stability—ideal for branch heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775015510168,"sku":"02352768","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6700-24-EI-2.jpg?v=1735630875"},{"product_id":"huawei-s6700-48-ei-switch","title":"Huawei S6700-48-EI Switch","description":"\u003ch4\u003eS6700-48-EI Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6700-48-EI with \u003cstrong\u003e48*10GE SFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe S6700 has industry-leading performance and provides up to 24 or 48 line-speed 10 GE ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6700 provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 512MB\u003c\/p\u003e\n\u003cp\u003eFlash 64MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"float: none;\" alt=\"S6700-48-EIAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6700-48-EIAppearance_and_Structure_600x600.png?v=1735631366\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (applicable in V200R001C01 and later versions, only 1000 Mbit\/s supported)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module (applicable in V200R005C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e5 m SFP+ high-speed copper cables (applicable in V200R005C02)\u003c\/li\u003e\n\u003cli\u003e10 m SFP+ high-speed copper cable (applicable in V200R001C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m AOC cables (applicable in V200R003C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESD jack\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eBefore installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eCX7E1FANA fan module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eCX7E1FANA fan module\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e500 W AC power module\u003c\/li\u003e\n\u003cli\u003e500 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e500 W AC power module\u003c\/li\u003e\n\u003cli\u003e500 W DC power module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e64 MB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e33.76\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEmpty: ≤ 5 kg (11.02 lb)\u003c\/li\u003e\n\u003cli\u003eFully configured: ≤ 8.5 kg (18.74 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10GE SFP+ ports (a maximum of eight physical ports)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e240 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eThe operating temperature of the switch is -5°C to +45°C (23°F to 113°F) when it uses SFP+ optical modules with 40 km or longer transmission distances.\u003c\/li\u003e\n\u003cli\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 55 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02352767\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? What's the uplink port type?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×Gigabit RJ45 ports (for access) + 4×10G SFP+ ports (for uplink\/expansion)—ideal for high-density enterprise networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 132 Mpps, latency ≤0.9ms—perfect for real-time data processing, video conferences, and cloud access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability for growing enterprises.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for cross-region or cross-building interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it a cost-effective classic model for mid-large enterprises?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than high-end switches, with 50-year MTBF and proven stability—ideal for classic enterprise heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775035007128,"sku":"02352767","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6700-48-EI-2.jpg?v=1735631496"},{"product_id":"huawei-s6720-30c-ei-24s-ac-switch","title":"Huawei S6720-30C-EI-24S-AC Switch","description":"\u003ch4\u003eS6720-30C-EI-24S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-30C-EI-24S-AC with \u003cstrong\u003e24*10GE SFP+ ports, 2*40GE QSFP+ ports, \u003c\/strong\u003e\u003cstrong\u003e2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The S6720-EI has industry-leading performance and provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S6720-30C-EI-24S-ACAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-30C-EI-24S-ACAppearance_and_Structure_600x600.png?v=1735632295\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported in V200R009 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCard supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q04Q01\u003c\/li\u003e\n\u003cli\u003eES5D21X08S00 (applicable in V200R012C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01 (applicable in V200R019C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e80.60 years (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 424.7 mm (1.75 in. x 17.4 in. x 16.72 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.8 mm (1.75 in. x 17.4 in. x 17.79 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.8 kg (21.61 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e233.7 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e147 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 72.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350DMN\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×40G QSFP+ ports—ideal for mid-data center high-density 10G access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), dual power redundancy—perfect for traditional mid-data center\/enterprise power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing nodes?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.35ms, hardware forwarding rate 480 Mpps, supports RoCE v2 lossless network—ideal for AI\/4K\/8K high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance mid-data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-sized data centers with traditional AC power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 40G switches, AC power compatibility, 60-year MTBF—ideal for mid-sized heavy-load core networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775055159448,"sku":"02350DMN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-30C-EI-24S-AC-2.jpg?v=1735632681"},{"product_id":"huawei-s6720-30c-ei-24s-dc-switch","title":"Huawei S6720-30C-EI-24S-DC Switch","description":"\u003ch4\u003eS6720-30C-EI-24S-DC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-30C-EI-24S-DC with \u003cstrong\u003e24*10GE SFP+ ports, 2*40GE QSFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-EI has industry-leading performance and provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-30C-EI-24S-DCAppearance_and_Structure_600x600.png?v=1735633631\" alt=\"S6720-30C-EI-24S-DCAppearance and Structure\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported in V200R009 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCard supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q04Q01\u003c\/li\u003e\n\u003cli\u003eES5D21X08S00 (applicable in V200R012C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01 (applicable in V200R019C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e80.60 years (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 424.7 mm (1.75 in. x 17.4 in. x 16.72 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.8 mm (1.75 in. x 17.4 in. x 17.79 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e9.8 kg (21.61 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e212.5 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e141 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 72.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350NHU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×10G SFP+ (all-optical) + 6×40G QSFP+ ports—ideal for mid-data center high-density 10G access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support DC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports -48V~-60V DC power (compatible with -36V~-72V), dual power redundancy—perfect for mid-data center centralized power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing nodes?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.35ms, hardware forwarding rate 480 Mpps, supports RoCE v2 lossless network—ideal for AI\/4K\/8K high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance mid-data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-sized data centers with high-reliability needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 40G switches, with 60-year MTBF, DC redundancy, and AI O\u0026amp;M—ideal for mid-sized heavy-load core networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775072592024,"sku":"02350NHU","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-30C-EI-24S-DC-2.jpg?v=1735633781"},{"product_id":"huawei-s6720-54c-ei-48s-ac-switch","title":"Huawei S6720-54C-EI-48S-AC Switch","description":"\u003ch4\u003eS6720-54C-EI-48S-AC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-54C-EI-48S-AC with \u003cstrong\u003e48*10GE SFP+ ports, 2*40GE QSFP+ ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-EI has industry-leading performance and provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-54C-EI-48S-ACAppearance_and_Structure_600x600.png?v=1735634476\" alt=\"S6720-54C-EI-48S-ACAppearance and Structure\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported in V200R009 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCard supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q04Q01\u003c\/li\u003e\n\u003cli\u003eES5D21X08S00 (applicable in V200R012C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01 (applicable in V200R019C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e79.39 years (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 424.7 mm (1.75 in. x 17.4 in. x 16.72 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.8 mm (1.75 in. x 17.4 in. x 17.79 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10.2 kg (22.49 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e296.1 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e190 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 72.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350DMP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×10G SFP+ (all-optical) + 6×40G QSFP+ ports—ideal for data center high-density 10G access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support AC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports 100-240V AC power (compatible with 90-264V), dual power redundancy—perfect for traditional data center\/enterprise power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.3ms, hardware forwarding rate 720 Mpps, supports RoCE v2 lossless network—ideal for AI\/4K\/8K high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large data centers with traditional AC power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 40G switches, AC power compatibility, 60-year MTBF—ideal for heavy-load core networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775081275544,"sku":"02350DMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-54C-EI-48S-AC-2.jpg?v=1735634668"},{"product_id":"huawei-s6720-54c-ei-48s-dc-switch","title":"Huawei S6720-54C-EI-48S-DC Switch","description":"\u003ch4\u003eS6720-54C-EI-48S-DC Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S6720-54C-EI-48S-DC with \u003cstrong\u003e48*10GE SFP+ ports, 2*40GE QSFP+ ports,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S6720-EI has industry-leading performance, provides line-speed 10GE access ports and line-speed 40GE uplink ports. It can be used in a data center to provide 10 Gbit\/s access to servers or function as a core switch on a campus network to provide 10 Gbit\/s traffic aggregation. In addition, the S6720-EI provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable, reliable, and secure data centers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e2*40GE QSFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 2GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S6720-54C-EI-48S-DCAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-54C-EI-48S-DCAppearance_and_Structure_600x600.png?v=1735635055\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing supported in V200R009 and later versions)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 and SFP-10G-ZR not supported)\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo 40GE QSFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eQSFP+ optical module\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to QSFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003cli\u003e10 m QSFP+ to 4*SFP+ AOC cable (applicable in V200R009C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eA 40GE QSFP+ optical port can be split into four 10GE ports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eESN label\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eYou can draw it out to view the ESN and MAC address of the switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRear card slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eCard supported:\n\u003cul\u003e\n\u003cli\u003eES5D21Q04Q01\u003c\/li\u003e\n\u003cli\u003eES5D21X08S00 (applicable in V200R012C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eES5D21X04S01 (applicable in V200R019C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFan slot\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable fan module:\u003c\/p\u003e\n\u003cp\u003eFAN-060B-B (Fan Box (B, Fan Panel Side Exhaust))\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e11\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cdiv\u003eApplicable power modules:\n\u003cul\u003e\n\u003cli\u003ePDC-350WA-B (350 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WA-B (600 W AC Power Module)\u003c\/li\u003e\n\u003cli\u003ePAC-600WD-B (600 W AC Power Module) (applicable in V200R020C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 40GE QSFP+ optical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMPO\/LC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ba\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e79.39 years (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±1 kV in differential mode, ±2 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 424.7 mm (1.75 in. x 17.4 in. x 16.72 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.8 mm (1.75 in. x 17.4 in. x 17.79 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10.2 kg (22.49 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAny 10GE SFP+ ports (a maximum of 16 physical ports)\u003c\/li\u003e\n\u003cli\u003eAny 40GE QSFP+ ports (a maximum of 6 physical ports)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 V AC to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e-48 V DC to -60 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/p\u003e\n\u003cp\u003e-38.4 V DC to -72 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e268.6 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTypical power consumption (30% of traffic load, tested according to ATIS standard)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e185 W (without card)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 72.1 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e02350NHV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What ports does it have? What's the uplink speed?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×10G SFP+ (all-optical) + 6×40G QSFP+ ports—ideal for data center high-density 10G access and 40G high-speed uplink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support DC power supply? What's the voltage range?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports -48V~-60V DC power (compatible with -36V~-72V), dual power redundancy—perfect for data center centralized power architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the latency and forwarding rate? Suitable for AI computing clusters?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Latency ≤0.3ms, hardware forwarding rate 720 Mpps, supports RoCE v2 lossless network—ideal for AI\/4K\/8K high-real-time scenarios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 40G QSFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 40km with single-mode transceivers—ideal for long-distance data center\/enterprise interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large data centers with high-reliability needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 35% cheaper than high-end 40G switches, with 60-year MTBF, DC redundancy, and AI O\u0026amp;M—ideal for heavy-load core networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45775099855000,"sku":"02350NHV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S6720-54C-EI-48S-DC-2.jpg?v=1735635169"},{"product_id":"zte-zxhn-f670l-v9-0-ont","title":"ZTE ZXHN F670L V9.0 ONT","description":"\u003ch4\u003e\u003cspan\u003eZTE ZXHN F670L V9.0 ONT Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4 x GE RJ-45 ports \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1 x FXS TEL RJ-11 port \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1 x USB 2.0 port \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2 x 2 802.11b\/g\/n Wi-Fi @ 2.4 GHz \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2 x 2 802.11a\/n\/ac Wi-Fi @ 5 GHz \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e4 x 5dBi high-gain antennas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ZXHN F670L is an AC1200 dual-band triple-play GPON gateway that provides four GE LAN ports and one phone port. It provides a dual-band concurrent Wi-Fi speed up to 1200 Mbps, allowing users to surf the internet, watch videos and play online games.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eKey Feature\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eMore Flexible Management\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with ITU-T G.988 OMCI \u003c\/li\u003e\n\u003cli\u003e Complies with TR-069 management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUltimate Wi-Fi Experience \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-band concurrent Wi-Fi speed up to 1.2 Gbps\u003c\/li\u003e\n\u003cli\u003eBand steering and smart roaming optimize\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eQoS High Reliability\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe highly reliable heat dissipation design guarantees its stable operation.\u003c\/li\u003e\n\u003cli\u003eThe dual image ensures uninterrupted services during software download or upgrade, enhancing software reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical Datasheet\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"667\" height=\"456\" style=\"border-collapse: collapse; width: 546px; height: 515px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"296\" style=\"width: 243px;\"\u003e \u003ccol width=\"371\" style=\"width: 302px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" width=\"296\" style=\"height: 23.15px; width: 177.6pt;\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"et2\" width=\"371\" style=\"width: 222.6pt; height: 23.15px;\"\u003eZTE ZXHN F670L V9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eInternet Service\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et2\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eMulticast Service\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et2\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eVoice Service\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et2\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eWi-Fi Service\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et2\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et3\" height=\"24\" width=\"296\" style=\"height: 23.15px; width: 177.6pt;\"\u003eEthernet Interface Quantity\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et2\"\u003e4(GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003ePOTS Interface Quantity\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eWi-Fi Interface\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e1(AC1200, Dualband)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et3\" height=\"24\" width=\"296\" style=\"height: 23.15px; width: 177.6pt;\"\u003eUSB Interface Quantity\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eCATV Interface Quantity\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eWAN\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eGPON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eButtons\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eWi-Fi, WPS, Reset, Power On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003eLEDs\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cspan\u003ePower, PON, LOS, WPS, TEL, LAN1, LAN2, LAN3, LAN4, WLAN, USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e\u003cspan\u003e210 x 130 x 35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et3\" height=\"24\" width=\"296\" style=\"height: 23.15px; width: 177.6pt;\"\u003eWall mounting hole distance\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003eAbout 200g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003eAC adapter: 12 VDC, 1.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e-5℃ to 45℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.15px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.15px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"height: 23.15px;\" class=\"et4\"\u003e-40℃ to 70℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\" style=\"height: 23.3px;\"\u003e\n\u003ctd class=\"et2\" height=\"24\" style=\"height: 23.3px;\"\u003eEnvironmental humidity\u003c\/td\u003e\n\u003ctd class=\"et5\" width=\"371\" style=\"width: 222.6pt; height: 23.3px;\"\u003e10% to 90% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eCharacteristics\u003c\/h5\u003e\n\u003cp\u003eThe F670L supports 802.11b\/g\/n Wi-Fi @2.4GHz(2x2) and 802.11a\/n\/ac Wi-Fi @5GHz(2x2) in Dual-Band concurrent Wi-Fi mode so that its Wi-Fi speed can reach up to 1.2Gbps, consisting of 300Mbps (802.11n 2x2 @ 2.4GHz) and 866Mbps (802.11ac 2x2 @5GHz).\u003c\/p\u003e\n\u003cp\u003eWith support for IPv4\/IPv6 Dual Stack, the F670L helps operators and end users to achieve future-proof network with smooth evolution.\u003c\/p\u003e\n\u003cp\u003eThe dual image ensures uninterrupted services during software download or upgrade, thereby enhancing software reliability. The highly reliable lightning protection design provides lightning and surge protection of 4 kV for the adapter, 1.5 kV for the POTS port, and 1.5 kV for the Ethernet ports.\u003c\/p\u003e\n\u003cp\u003eThe QoS features of the F670L enable service providers to design QoS policies and prioritize mission-critical services such as IPTV and VoIP freely based on their individual service plans. So, service providers could deliver real multi-play applications to users and increase network efficiency.\u003c\/p\u003e\n\u003cp\u003eThe F670L can be managed by two ways: one is complete OMCI complying with ITU-T G.988, the other is OMCI plus TR-069 complying with BBF TR-142 framework. Service providers can choose their preferred ways to manage the device.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e","brand":"ZTE","offers":[{"title":"2-antenna Version","offer_id":45775131836568,"sku":"","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4-antenna Version","offer_id":45775131869336,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/F670L-V9.0-1.jpg?v=1735635589"},{"product_id":"huawei-s5735-l12t4s-a-switch","title":"Huawei S5735-L12T4S-A Switch","description":"\u003ch4\u003eS5735-L12T4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThis switch is one of the Huawei S5735-L switches, which comes with \u003cstrong\u003e12* 10\/100\/1000Base-T ports,\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e12*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S5735-L12T4S-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L12T4S-AAppearance_and_Structure_600x600.png?v=1735783415\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwelve 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, a maximum transmission distance of 0.4 km, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e​\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98.6 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3.83 kg (8.44 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e29 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e23 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eThe operating temperature of the switch is -5°C to +40°C (23°F to 104°F) when it uses GE SFP optical modules with 40 km or longer transmission distance.\u003c\/p\u003e\n\u003cdiv\u003eWhen SFP+ copper cables or dedicated stack cables are used to set up a stack, the switch can operate in the following temperature range:\n\u003cul\u003e\n\u003cli\u003e-5°C to +45°C (23°F to 113°F) (installed in the ventilation cabinet, with the wind speed of at least 40 LFM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eWhen SFP+ AOC cables or 10GE SFP+ optical modules are used to set up a stack, the switch can operate in the following temperature range:\n\u003cul\u003e\n\u003cli\u003e-5°C to +45°C (23°F to 113°F) (installed in the ventilation cabinet shipped with fans with a fan speed of at least 200 LFM)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise-free (no fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010918\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45778858180760,"sku":"98010918","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L12T4S-A-2.jpg?v=1735784133"},{"product_id":"huawei-s5735-l12p4s-a-switch","title":"Huawei S5735-L12P4S-A Switch","description":"\u003ch4\u003eS5735-L12P4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThis switch is one of  the Huawei S5735-L switch with \u003cstrong\u003e12*PoE+10\/100\/1000Base-T ports, \u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e12*\u003cspan\u003ePoE+\u003c\/span\u003e10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L12P4S-AAppearance_and_Structure_600x600.png?v=1735784762\" alt=\"S5735-L12P4S-AAppearance and Structure\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwelve \u003cspan\u003ePoE+ \u003c\/span\u003e 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, a maximum transmission distance of 0.4 km, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e​\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e85.52 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.24 kg (9.35 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 49 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 441 W (PoE: 360 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e38 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 57.7 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010922\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45778889506968,"sku":"98010922","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L12P4S-A-2.jpg?v=1735785018"},{"product_id":"huawei-s5735-l24p4s-a-switch","title":"Huawei S5735-L24P4S-A Switch","description":"\u003ch4\u003eS5735-L24P4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS5735-L24P4S-A is the Huawei S5735-L switch with \u003cstrong\u003e24*PoE+10\/100\/1000Base-T ports, 4* GE SFP ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*\u003cspan\u003ePoE+\u003c\/span\u003e10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S5735-L24P4S-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24P4S-AAppearance_and_Structure_600x600.png?v=1735785492\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwelve \u003cspan\u003ePoE+ \u003c\/span\u003e 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, a maximum transmission distance of 0.4 km, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e​\u003cspan\u003eTechnical specifications\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e92.2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.31 kg (9. lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 53 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 451 W (PoE: 380 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 57.7 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010924\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45778921783448,"sku":"98010924","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24P4S-A-2.jpg?v=1735785636"},{"product_id":"huawei-s5735-l24t4x-a-switch","title":"Huawei S5735-L24T4X-A Switch","description":"\u003ch4\u003eS5735-L24T4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS5735-L24T4X-A is the Huawei S5735-L switch with \u003cstrong\u003e24*10\/100\/1000Base-T ports, 4*10 GE SFP ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S5735-L24T4X-A Appearance\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24T4X-AAppearance_and_Structure_600x600.png?v=1735785998\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e​​\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e​\u003cspan\u003eTechnical specifications\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50.68 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 kg (8.82 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e27 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 47.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010920\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45778966708376,"sku":"98010920","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24T4X-A-2.jpg?v=1735786125"},{"product_id":"huawei-s5735-l24p4x-a-switch","title":"Huawei S5735-L24P4X-A Switch","description":"\u003ch4\u003eS5735-L24P4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS5735-L24P4X-A is the Huawei S5735-L switch with \u003cstrong\u003e24*PoE+10\/100\/1000Base-T ports, 4*10 GE SFP ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*\u003cspan\u003ePoE+\u003c\/span\u003e10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24P4X-AAppearance_and_Structure_600x600.png?v=1735786705\" alt=\"S5735-L24P4X-AAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four PoE+ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e57.07 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.31 kg (9.5 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 56 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 458 W (PoE: 380 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e43 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 57.7 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010927\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 370W, max 30W per port (802.3at) \/ 15.4W (802.3af)—supports 24 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for SME branch\/store interconnection without repeaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—grows with your small business.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it easy to use for small businesses without professional IT staff?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! Web-based management + AI fault alerts make operation simple—no professional IT knowledge required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for 24-channel security camera deployment?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 48% cheaper than traditional power solutions, with stable PoE supply and 10G high-speed transmission—perfect for small-scale security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779002523800,"sku":"98010927","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L24P4X-A-2.jpg?v=1735787174"},{"product_id":"huawei-s5735-l32st4x-a-switch","title":"Huawei S5735-L32ST4X-A Switch","description":"\u003ch4\u003eS5735-L32ST4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThis Huawei switch with \u003cstrong\u003e24*100\/1000BASE-X ports, 8*10\/100\/1000BASE-X ports, 4*10 GE SFP+ ports, 1*AC power input fixed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*100\/1000BASE-X ports\u003c\/p\u003e\n\u003cp\u003e8*10\/100\/1000BASE-X ports\u003c\/p\u003e\n\u003cp\u003e4*10 GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L32ST4X-AAppearance_and_Structure_600x600.png?v=1735787818\" alt=\"S5735-L32ST4X-AAppearance and Structure\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 100\/1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module\u003c\/li\u003e\n\u003cli\u003eGE optical module (maximum transmission distance ≤ 40 km)\u003c\/li\u003e\n\u003cli\u003eGE copper module (works at 10 Mbit\/s, 100 Mbit\/s, or 1000 Mbit\/s)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEight 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003ePort Description\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 100\/1000BASE-X port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical interface attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Attributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e Attributes of a 10GE SFP+ port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e85.87 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.31 kg (9.5 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports, 100\/1000BASE-X ports, or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e65 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 53.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010929\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? What's the uplink port type?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 32×Gigabit RJ45 ports (for access) + 4×10G SFP+ ports (for uplink\/expansion)—ideal for SME high-density networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 112 Mpps, latency ≤0.8ms—perfect for real-time data processing, video conferences, and cloud access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability for growing SMEs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for cross-region SME branch interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small and medium-sized enterprises with heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than high-end switches, with enterprise-level reliability—ideal for SME heavy-load high-speed networking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779052003480,"sku":"98010929","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L32ST4X-A-2.jpg?v=1735788069"},{"product_id":"huawei-s5735-l48t4s-a-switch","title":"Huawei S5735-L48T4S-A Switch","description":"\u003ch4\u003eS5735-L48T4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eThis switch is one of the Huawei S5735-L switches, which comes with \u003cstrong\u003e48* 10\/100\/1000Base-T ports,\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4*1000BASE-X ports\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S5735-L48T4S-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48T4S-AAppearance_and_Structure_600x600.png?v=1735788814\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, a maximum transmission distance of 0.4 km, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46.36 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.42 kg (9.75 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e53 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e37 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 53.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010933\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? Is the 10G port compatible with standard SFP+ modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×Gigabit RJ45 ports + 4×10G SFP+ ports (compatible with standard multi-mode\/single-mode modules)—ideal for cost-effective SME networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 144 Mpps, latency ≤0.8ms—perfect for real-time data processing, video conferences, and cloud access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability for growing SMEs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with standard single-mode transceivers—ideal for cross-region SME branch interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small and medium-sized enterprises with general heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end switches, with standard SFP+ compatibility and enterprise reliability—ideal for SME heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779094143128,"sku":"98010933","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48T4S-A-2.jpg?v=1735788937"},{"product_id":"huawei-s5735-l48t4x-a-switch","title":"Huawei S5735-L48T4X-A Switch","description":"\u003ch4\u003eS5735-L48T4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS5735-L48T4X-A is the Huawei S5735-L switch with \u003cstrong\u003e48*10\/100\/1000Base-T ports, 4*10 GE SFP ports,1*AC power input fixed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"S5735-L48T4X-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48T4X-AAppearance_and_Structure_600x600.png?v=1735789680\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eForty-eight 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003etem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e41.48 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±6 kV in differential mode, ±6 kV in common mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4.42 kg (9.75 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e54 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e39 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003cp\u003eThe operating temperature of the switch is -5°C to +45°C (23°F to 113°F) when it uses 10GE SFP+ optical modules with 40 km or longer transmission distances.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 53.3 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010936\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eFrequently Asked Questions\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? What's the uplink port type?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×Gigabit RJ45 ports (for access) + 4×10G SFP+ ports (for uplink\/expansion)—ideal for SME high-density networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 144 Mpps, latency ≤0.8ms—perfect for real-time data processing, video conferences, and cloud access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability for growing SMEs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for cross-region SME branch interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for small and medium-sized enterprises with heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 45% cheaper than high-end switches, with enterprise-level reliability—ideal for SME heavy-load high-speed networking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779159613592,"sku":"98010936","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48T4X-A-2.jpg?v=1735789786"},{"product_id":"huawei-s5735-l48p4x-a-switch","title":"Huawei S5735-L48P4X-A Switch","description":"\u003ch4\u003eS5735-L48P4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eS5735-L48P4X-A is the Huawei S5735-L switch with \u003cstrong\u003e48*PoE+10\/100\/1000Base-T ports, 4*10 GE SFP ports, 2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eHuawei CloudEngine S5735-L is a series of simplified gigabit access switches that provide 12–48 flexible all-GE downlink ports and four fixed GE or 10 GE uplink ports. They are designed for enterprise campus network access and gigabit to the desktop. Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*\u003cspan\u003ePoE+\u003c\/span\u003e10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S5735-L48P4X-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48P4X-AAppearance_and_Structure_600x600.png?v=1735790395\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e    \u003cbr\u003eForty-eight PoE+ 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eJack for AC power cable locking strap\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eThe AC power cable locking strap is not delivered with the switch.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC socket\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eIt is used with an AC power cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAttributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.1075%;\"\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 61.6716%;\"\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1075%;\"\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.6716%;\"\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1075%;\"\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.6716%;\"\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1075%;\"\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.6716%;\"\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1075%;\"\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.6716%;\"\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e61.7 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.7 kg (19.18 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNot providing the PoE function: 80 W\u003c\/li\u003e\n\u003cli\u003e100% PoE loads: 914 W (PoE: 874 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e59 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 58.9 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010944\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eFrequently Asked Questions\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the total PoE power and maximum per-port power?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Total PoE power 740W, max 30W per port (802.3at) \/ 15.4W (802.3af)—supports 48 high-power PoE devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers—ideal for long-distance campus\/branch interconnection without repeaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it suitable for small and medium-sized enterprises with limited IT resources?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Absolutely! Web-based management + AI operation and maintenance (link fault early warning) make it easy to use—no professional IT team required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for 48-channel security camera deployment?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 50% cheaper than traditional power supply solutions, with stable PoE power supply and 10G high-speed transmission—ideal for large-scale security deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779179241624,"sku":"98010944","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735-L48P4X-A-2.jpg?v=1735790499"},{"product_id":"huawei-s5735s-s24t4s-a-switch","title":"Huawei S5735S-S24T4S-A Switch","description":"\u003ch4\u003eS5735S-S24T4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S5735S-S24T4S-A switch supports \u003cstrong\u003e4*1000BASE-X ports, 24*10\/100\/1000BASE-T ports, 1*AC power module equipped,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735S-S is a series of standard gigabit access switches that provide 24–48 flexible all-GE downlink ports and four fixed 10 GE uplink ports. They are designed for enterprise campus network access and aggregation and data center access. Built on next-generation, high-performance hardware and with the Huawei Versatile Routing Platform (VRP), CloudEngine S5735S-S switches boast advanced features, such as enhanced Layer 3 functionality, simplified O\u0026amp;M, flexible Ethernet networking, and mature IPv6 capabilities.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e24*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*1000BASE-X ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S24T4S-AAppearance_and_Structure_600x600.png?v=1735791252\" alt=\"S5735S-S24T4S-AAppearance and Structure\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e69.42 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7.89 kg (17.4 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e44 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e29 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 58.9 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010939\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? Is the 10G port compatible with standard SFP+ modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×Gigabit RJ45 ports + 4×10G SFP+ ports (compatible with standard multi-mode\/single-mode modules)—ideal for cost-effective networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 88 Mpps, latency ≤0.9ms—perfect for real-time data processing, video conferences, and high-speed file transfers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service for large enterprises.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with standard single-mode transceivers (550m with multi-mode)—ideal for cross-region interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with general heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than high-end switches, with standard SFP+ compatibility and enterprise reliability—ideal for general heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779199000728,"sku":"98010939","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S24T4S-A-2.jpg?v=1735791492"},{"product_id":"huawei-s5735s-s48t4s-a-switch","title":"Huawei S5735S-S48T4S-A Switch","description":"\u003ch4\u003eS5735S-S24T4S-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S5735S-S48T4S-A switch supports \u003cstrong\u003e4*1000BASE-X ports, 48*10\/100\/1000BASE-T ports, 1*AC power module equipped,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735S-S is a series of standard gigabit access switches that provide 24–48 flexible all-GE downlink ports and four fixed 10 GE uplink ports. They are designed for enterprise campus network access and aggregation and data center access. Built on next-generation, high-performance hardware and with the Huawei Versatile Routing Platform (VRP), CloudEngine S5735S-S switches boast advanced features, such as enhanced Layer 3 functionality, simplified O\u0026amp;M, flexible Ethernet networking, and mature IPv6 capabilities.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e48*10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003e4*1000BASE-X ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S5735S-S48T4S-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S48T4S-AAppearance_and_Structure_600x600.png?v=1735792186\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003eForty-eight 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 1000BASE-X ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules:\n\u003cul\u003e\n\u003cli\u003eFE optical module (applicable in V200R021C00 and later versions)\u003c\/li\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (only used for stack connection, OSXD22N00 not supported, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables (only used for stack connection, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAttributes of a 1000BASE-X Ethernet optical port\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3z\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e74.7 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8.37 kg (18.45 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e58 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e41 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 58.9 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010942\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? Is the 10G port compatible with standard SFP+ modules?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 48×Gigabit RJ45 ports + 4×10G SFP+ ports (compatible with standard multi-mode\/single-mode modules)—ideal for cost-effective networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for data center server access?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 144 Mpps, latency ≤0.8ms—perfect for data center access, cloud computing, and high-speed data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service for large enterprises.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with standard single-mode transceivers (550m with multi-mode)—ideal for cross-region interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with general heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than high-end switches, with standard SFP+ compatibility and enterprise reliability—ideal for general heavy-load networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779230261400,"sku":"98010942","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S48T4S-A-2.jpg?v=1735796893"},{"product_id":"huawei-s5735s-s24t4x-a-switch","title":"Huawei S5735S-S24T4X-A Switch","description":"\u003ch4\u003eS5735S-S24T4X-A Hardware Description\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eIntroduction\u003c\/h5\u003e\n\u003cp\u003eHuawei S5735S-S24T4X-A switch supports \u003cstrong\u003e4*10GE SFP+ ports, 24*1000BASE-T ports, 1*AC power module equipped,2 power module slots, hot-swappable power modules are optional: 2*AC, 2*DC, 1*AC+1*DC, 1*AC or 1*DC.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHuawei CloudEngine S5735S-S is a series of standard gigabit access switches that provide 24–48 flexible all-GE downlink ports and four fixed 10 GE uplink ports. They are designed for enterprise campus network access and aggregation and data center access. Built on next-generation, high-performance hardware and with the Huawei Versatile Routing Platform (VRP), CloudEngine S5735S-S switches boast advanced features, such as enhanced Layer 3 functionality, simplified O\u0026amp;M, flexible Ethernet networking, and mature IPv6 capabilities.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cp\u003e4*10GE SFP+ ports\u003c\/p\u003e\n\u003cp\u003e24*1000BASE-T ports\u003c\/p\u003e\n\u003cp\u003eMemory (RAM) 1GB\u003c\/p\u003e\n\u003cp\u003eFlash 512MB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eAppearance and Structure\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"S5735S-S24T4X-AAppearance and Structure\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S24T4X-AAppearance_and_Structure_600x600.png?v=1735796682\"\u003e\u003c\/div\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwenty-four 10\/100\/1000BASE-T ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour 10GE SFP+ ports\u003c\/p\u003e\n\u003cdiv\u003eApplicable modules and cables:\n\u003cul\u003e\n\u003cli\u003eGE optical module\u003c\/li\u003e\n\u003cli\u003eGE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003eGE copper module (100M\/1000M auto-sensing)\u003c\/li\u003e\n\u003cli\u003e10GE SFP+ optical module (OSXD22N00 not supported)\u003c\/li\u003e\n\u003cli\u003e10GE-CWDM optical module\u003c\/li\u003e\n\u003cli\u003e10GE-DWDM optical module\u003c\/li\u003e\n\u003cli\u003e1 m and 3 m SFP+ high-speed copper cables\u003c\/li\u003e\n\u003cli\u003e3 m and 10 m SFP+ AOC cables\u003c\/li\u003e\n\u003cli\u003e0.5 m and 1.5 m SFP+ dedicated stack copper cables (used for zero-configuration stacking, applicable in V200R019C10 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne console port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne ETH management port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne USB port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne PNP button\u003c\/p\u003e\n\u003cdiv\u003eNOTICE:\n\u003cdiv\u003e\n\u003cp\u003eTo restore the factory settings and reset the switch, hold down the button for at least 6 seconds.\u003c\/p\u003e\n\u003cp\u003eTo reset the switch, press the button.\u003c\/p\u003e\n\u003cp\u003eResetting the switch will cause service interruption. Exercise caution when you press the PNP button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e7\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGround screw\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003eIt is used with a ground cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 1\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e9\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower module slot 2\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eApplicable power module:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePAC60S12-AR (60 W AC\u0026amp;240 V DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC1000S12-DB (1000 W DC Power Module)\u003c\/li\u003e\n\u003cli\u003ePDC180S12-CR (180 W DC Power Module) (applicable in V200R020C00 and later versions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cspan\u003ePort Description\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAttributes of a 10\/100\/1000BASE-T Ethernet electrical port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRJ45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3, IEEE802.3u, IEEE802.3ab\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10\/100\/1000 Mbit\/s auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum transmission distance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e Attributes of a 10GE SFP+ port\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eAttribute\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConnector type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLC\/PC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOptical port attributes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDepend on the optical module used\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandards compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEEE802.3ae\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE\/10GE auto-sensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/h5\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMemory (RAM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFlash\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e512 MB in total. To view the available flash memory size, run the display version command.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time between failures (MTBF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e69.42 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMean time to repair (MTTR)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAvailability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026gt; 0.99999\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eService port surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCommon mode: ±7 kV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower supply surge protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsing AC power modules: ±6 kV in differential mode, ±6 kV in common mode\u003c\/li\u003e\n\u003cli\u003eUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions (H x W x D)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBasic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)\u003c\/li\u003e\n\u003cli\u003eMaximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (with packaging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e7.89 kg (17.4 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStack ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAny 10\/100\/1000BASE-T ports or 10GE SFP+ ports (applicable in V200R019C10 and later versions)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRTC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRPS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNot supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 100 V AC to 240 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 240 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -48 V DC to -60 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eAC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage DC input: 190 V DC to 290 V DC\u003c\/li\u003e\n\u003cli\u003eDC input: -38.4 V DC to -72 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum power consumption (100% throughput, full speed of fans)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e46 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eTypical power consumption (30% of traffic load)\n\u003cul\u003e\n\u003cli\u003eTested according to ATIS standard\u003c\/li\u003e\n\u003cli\u003eEEE enabled\u003c\/li\u003e\n\u003cli\u003eNo PoE power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e31 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cp\u003eThe switch cannot be started when the ambient temperature is lower than 0°C (32°F).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShort-term operating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)\u003c\/p\u003e\n\u003cdiv\u003eNOTE:\n\u003cdiv\u003e\n\u003cp\u003eWhen the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).\u003c\/p\u003e\n\u003cdiv\u003eThe equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:\n\u003cul\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.\u003c\/li\u003e\n\u003cli\u003eThe equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.\u003c\/li\u003e\n\u003c\/ul\u003e\nThe equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.\u003c\/div\u003e\n\u003cp\u003eThe equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise under normal temperature (27°C, sound power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 58.9 dB(A)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5% to 95%, noncondensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating altitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5000 m (0-16404 ft.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eEMC certification\u003c\/li\u003e\n\u003cli\u003eSafety certification\u003c\/li\u003e\n\u003cli\u003eManufacturing certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePart number\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e98010967\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003ch5\u003e\n\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"auto-hide-last-sibling-br\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: How many ports does it have? What's the uplink port type?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 24×Gigabit RJ45 ports (for access) + 4×10G SFP+ ports (for uplink\/expansion)—ideal for high-density enterprise networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the forwarding rate and latency? Suitable for real-time data processing?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Hardware forwarding rate 88 Mpps, latency ≤0.9ms—perfect for real-time data processing, video conferences, and high-speed file transfers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Does it support stacking and dual power supply?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! Supports iStack stacking (max 9 switches) + optional dual power redundancy—ensures scalability and non-stop service for large enterprises.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: What's the maximum transmission distance of the 10G SFP+ ports?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Up to 100km with single-mode transceivers (550m with multi-mode)—ideal for cross-region or cross-building interconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ\u003c\/strong\u003e: Is it cost-effective for mid-large enterprises with heavy-load needs?\n\u003cdiv class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Yes! 40% cheaper than high-end enterprise switches, with enterprise-level performance and reliability—ideal for heavy-load high-speed networking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Huawei","offers":[{"title":"Default Title","offer_id":45779251331224,"sku":"98010967","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0685\/1529\/9480\/files\/S5735S-S24T4X-A-2.jpg?v=1735796935"}],"url":"https:\/\/huatelecom.com\/collections\/optical-networking.oembed?page=53","provider":"HuaTelecom.com","version":"1.0","type":"link"}